HomeMy WebLinkAboutSUB201300023 Review Comments Road Plan and Comps. 2013-03-12�pF A vt�r�1Q COUNTY OF ALBEMARLE Department of Community Development 401 McIntire Road, Room 227 Charlottesville, Virginia 22902 -4596 Phone (434) 296 -5832 Fax (434) 972 -4126 Project: Glenmore Leake K2 Lots 24 -27 & 29 Plan preparer: Collins Engineering [434- 293 -3719] Owner or rep.: Central Virginia Real Estate Ventures, LLC [434- 962 -2150] Plan received date: 19 Feb 2013 Date of comments: 12 Mar 2013 Reviewer: Michelle Roberge A. Road and drainage plans (SUB201300023) 1. Please provide the Albemarle County private road notes on sheet 4. The public road notes are not necessary. 2. It appears the road width for Carroll Creek Road varies. Please show the transition widths on the site plan. The proposed easements will be required on the final plat. 3. A zoning variance is required for the proposed Carroll Creek Road. The existing road is currently an emergency access for Running Deer Drive. As such, it cannot have driveways or provide frontage. Once this is resolved and the use is clarified, please provide ADT to determine pavement section. 4. Site distance easements will be required on the final plat. 5. Please provide a shared driveway for lot 26 and 27 due to section 14 -412. A driveway cannot exceed a 16% grade. A shared driveway will also reduce the disturbance of critical slopes. Please note a portion of this lot appears to be on another parcel. This will need to be resolved with Zoning prior to the approval of this subdivision application. 6. I recommend adding a separate utility plan for the proposed water and sewer. The site plan will be easier to read at a 1"-50' scale by separating the utility sheet. Include the existing easements with DB and page number. Also add DB and page number for the existing sanitary easement that's missing on sheet 2. Please show the 20' proposed utility easements. B. Stormwater Management (WP0201300015) 1. The ditch line falls outside the 50' ROW on Farringdon Road. Please show the drainage easement for the ditch along Farringdon Road and Carroll Creek Road if it is outside the ROW. 2. Per 14 -431, show drainage easements for all drainage outfalls to the boundary of the property. Please provide for lot 29. 3. Provide the SWM facility access easement that encompasses the 100 yr water mark. Also provide the drainage easement for the SWM facility. 4. Please show the extended detention basin detail and riser detail to scale. The SWM facility notes that the existing embankment will be part of the proposed basin. There are some concerns to take into consideration. 1) The design shows that steel plate collars will be installed for the existing 36" pipe. However, this will require ripping out a portion of the existing road. 2) The only information provided about the embankment is that it is existing. A geotech study would be necessary to determine the suitability of the embankment to impound water. 3) This facility is designed to have deep water judging by the height of the riser, and safety is a concern for this proposed subdivision. I recommend a permanent fence around the facility. 4) The forebay does not appear to function separately from the basin itself. Please regrade and redesign to separate the forebay from the Engineering Review Comments Page 2 of 2 basin. An alternative solution is to push the basin away from the road and regrade area so the basin is not too deep. Also, provide a separate embankment with an impervious liner and a forebay that is separate from the basin 6. Per the Albemarle County Design Standards Manual, a 15" pipe is the minimum pipe size allowed. Please revise culverts to show 15" pipes. I recommend at least V cover for culverts, which would require deepening the ditches. C. Erosion Control Plan (WPO201300015) 1. Note 6 explains that permanent stabilization is required for all slopes steeper than 3:1. Please place a note for the ditch along Carroll Creek Road for EC -2. 2 Only one construction entrance and one staging area are required for this E &S plan. A CE for each lot can only be proposed if a site plan is submitted for each lot or if these lots are to be developed using erosion control agreements with each building permit. 3. Please show dust control on plans. 4. It is difficult to see the silt fence on plans. Please lighten the hatching of the critical slopes. 5. Please provide silt fence along the northern boundary of lot 27. 6. Please show the limits of disturbance on the plan. 7. Please show the safety fence around the SWM facility on all plans. Sincerely, rEvf- Michelle Roberge File: El_rp,esc,swm,fsp_GEB _ template.doc