HomeMy WebLinkAboutSUB201300057 Review Comments Final Plat 2013-07-10of Al,
vI IGI
County of Albemarle
Department of Community Development
401 McIntire Road,
Charlottesville, VA, 22902
Phone 434 - 296 -5832
Fax 434 - 972 -4126
Memorandum
To: Kristopher Winters
From: Christopher P. Perez, Senior Planner
Division: Planning
Date: July 10, 2013
Subject: SUB 2013— 00057 Whittington Subdivision (Phase A) - Final Subdivision Plat prior to a Preliminary
The County of Albemarle Planning Division will approve the plat referenced above once the following comments
have been satisfactorily addressed (The following comments are those that have been identified at this time.
Additional comments or conditions may be added or eliminated based on further review.): [Each comment is
preceded by the applicable reference, which is to the Subdivision /Zoning Ordinances unless otherwise
specified.]
1. [14- 302(B)5] Zoning classification. Proffers apply to this site. Appropriate reference to them must be noted
on this plat as well as future plats and plans.
Rev 1. Comment not addressed. On sheet 1, note #3 references the ZMA # of the rezoning but it does
not reference that proffers are associated with this development. All rezoning do not contain
proffers, this specific project does, and thus it needs to be referenced. Revise.
2. [ZMA2006011 Application PIG 3-19.S .4 -213A, 14- 302(B)8] Setback;, „nt ,Jote #15 appear-
be incorrect with regard to front setbacks to existing public r/w (currently listed as 45' on the plat); howev-
the rezoning application plan specifies 75' to existing public r /w. Revise. It is advisable that the applican
delineate and label the 75' setback on the plat as this setback is measured from the new right -of -way line,
thus it appears this may impact buildable area of Lots 1, 51, 52, 53, 54, and 56. Also, an additional setback
note shall be included on the plat for Rear Yard Setbacks. The rezoning specifies that "Rear lots adjoining
RA districts shall have 35' rear setbacks." Please add this setback note to General Note #15, as it appears
Lots 56 and 57 will be affected by this provision. Also, there is also a `build -to' distance of 30' for single -
family detached; please add this information to the setback notes as well. Rev 1. Comment addressed.
3. [ZMA2006011 Proffer 6] As submitted the right -of -way dedication fronting Open Space B, Lot 1, and
Kendra Street (entrance to the property) does not appear to meet the required 55' dedication from the
centerline of Rte 631 as described in proffer #6. Revise Rev 1. Comment addressed.
4. [ZMA2006011 Proffer 1] The maximum number of lots permitted in Whittington is 96. A table providing the
xisting and proposed lots and total permitted must be provided on the plat and updated with each submitt�
)r various phases. Revise. Rev 1. Comment addressed.
5. [ZMA2006011 Proffer 2] Lot Size. Each lot is required to be a minimum of 40.000 gross Square Foot in
area. Provide a note on the plat which states the minimum lot size requirement for this development. Also,
on the plat provide the Square Footage calculations for each lot rather than the acreages. Most notably, it
appears "Lot 56" is below the rpm sired square footage. Revise appropriately.
Rev 1. Comment not completely addressed. As previously requested provide a note on the plat
which states the minimum lot size requirement for this development.
6. tLIVIAZUUbu-i-1 Application Tian ana -i4 -susrj iaenrincanon Or secrions, OIOCKS, ano ions. I ne lot numbers
within the subdivision do not match the lot numbering provided/ approved in the application plan. Staff has
noted that the road plans utilize these same incorrect lot designations; however, the road plan does not
create the lots, rather the subdivision plat does. Thus the lot numbers on this plat should be revised to
match the application plan. Revise. Rev 1. Comment addressed.
7. [ZMA2006011 Application Plan] The 25' screening easement is mislabeled on the plat, the appropriate title
of this easement is "25' screening and landscape easement ". Revise. Rev 1. Comment addressed.
8. [18 -19.6] Minimum Area Requirements for Open Space and Recreational Uses in PRD District. On the plat
provide the percentage of open space which is being provided in this phase. Rev 1. Comment addressed.
9. FZMA2006011 Application Plan, 18- 19.6.2 and 18 -4.16] Recreational Area Requirements and
recreational Regulations. It appears there should be a Pocket Park located in Open Space B, and a Rain
arden located in Open Space A, and a Pocket Park w/ Picnic Shelter located in Open Space D per the
pplication plan. Please indicate these items on the plat. Rev 1. Comment addressed
10. [14 -317 and Proffer 1 & 8 ] Instrument evidencing maintenance of certain improvements. Documents
relevant to dedication and /or maintenance of open space, 25' screening and landscape easement, and 10'
and 20' access easement must be provided for review to the County Attorney in order for final subdivision
plat approval. Please submit a draft of this document to me and I will review it and forward it to the County
Attorney for his review/ approval.
Rev 1. Comment not addressed. Please submit a draft of this document to me and I will review it and
forward it to the County Attorney for his review/ approval.
11. [14 -317, 303L] Instrument evidencing maintenance of certain improvements. A Deed of Dedication and
Deed of Easement is needed for the drainage easements shown on the plat. The applicant should contact
the County's Attorney's Office for the most recent deed template for drainage easements to be included with
the next submittal of the plat. Please submit a draft of this document to me and I will review it and forward it
to the County Attorney for his review /approval.
Rev 1. Comment not addressed. Please submit a draft of this document to me and I will review it and
forward it to the County Attorney for his review/ approval.
12. L114-302(A),,
critical slope waivers (per 1977 rezoning and 2006 rezoning). Be advised that this does not replace c
negate the requirements listed in proffer # 4. Rev 1. Comment addressed.
13. [Comment] Proposed Easements. Depict the proposed 20' water line easen,„,,, ..,,,.„
the proposed r/w (Kendra Street). Assure that the waterline easement is permitted under the pavement
section of the right -of -way, as the road plan shows it on the unpaved portion of the r/w easement and VDOT
previously provided comments on this item during the road plan review. Please work with VDOT to assure
correct location of this easement and depict it on the plat. Rev 1. Comment addressed.
14. [14 -303S] Control points. Control points must be submitted. At the option of the subdivider, the control
points may be shown on a copy of the final plat, rather than on the original final plat. Rev 1. Comment
addressed.
15. [14 -3030] Signature of Agent On Sheet 1 under County Approval, the plat provides a space for the "Director
of Planning "; however, the appropriate title of the person able to approve this plat is "Agent for the Board of
Supervisors ". Please revise. Rev 1. Comment addressed.
16. [Comment] On sheet 1 omit the VDOT Approval signature line as this is neither required nor appropriate for
this plat. Rev 1. Comment addressed.
17. [14- 302(B)1] General information. Add a revision date to all future submittals. Rev 1. Comment
addressed.
2
18. [14 -435] Surety in lieu of completion of on -site improvements. This plat cannot be signed by the County until
all necessary bonds have been posted for this phase.
Rev 1. Comment not addressed.
19. [14- 216(B)5] On the plat provide a note which reads: `All new public street right -of -ways shown hereon are
hereby Dedicated to Public Use" Rev 1. Comment addressed.
20. [14 -426, 428] Dedication of land for public use. Area X and Y is being dedicated to VDOT. On the plat
assure that this section of right -of -way is labeled "Hereby Dedicated to Public Use" Revise. Rev 1.
Comment addr —ed
21. [14 -414, 430] Public water and sewerage, Dedication of water and sewerage system. ACSA approval is
required. Rev 1. Pending.
22. [New Comment] Note #14 references the previous incorrect Lot numbers. Since the lot numbers have been
revised this note should also be revised to utilize /reference the correct lot #'s. Revise.
Engineering – Max Green
1. "'EyeBrow Road" appears to require a right -of -way width of 40'.
2. Roads will be built and accepted into the State System or bonded prior to final plat approval. Please request
a road bond amount for SUB201100029 Road Plan.
3. Approved WPO plans are required Prior to final plat approval. E &SC plans and fees have been submitted
for review, but SWM plans have not posted the review fee. SWM drainage easements will be reviewed upon
approval of the WPO plans.
E911 - Andrew Slack
1. The road name "Victor Lane" should be changed to another road name designator (i.e. Way, Place, Court,
Drive, etc). There is a road named "Victoria Lane" already existing in the County. To reduce potential confusion
from ECC Dispatchers or Emergency Responders. Please contact this office with further questions.
Fire and Rescue – Robbie Gilmer
Fire Rescue has no objections to the plat but keep in mind the following things.
1. 20 ft wide unobstructed travel way on all streets.
2. 96 ft Fc /Fc for Cul -de- sac's.
3. Turning Radii shall not be less than 25 ft.
Building Inspections - Jay Schlothauer
1. No objection
VDOT – Troy Austin
No objections per initial review of the plans.
ACSA –Alex Morrison
Comments pending
Pending comments from various review committee members will be forwarded to the applicant once received.
Please contact Christopher P. Perez at the Department of Community Development 296 -5832 ext. 3443 for
further information.