Loading...
HomeMy WebLinkAboutSUB201300030 Review Comments Road Plan and Comps. 2013-06-13Michael Koslow From: Ellie Ray Sent: Thursday, June 13, 2013 5:15 PM To: Michael Koslow Subject: FW: Westlake Hills Attachments: SUB201200038; RWSA General Notes.doc Follow Up Flag: Follow up Flag Status: Flagged Ellie Carter Ray, PLA Senior Planner Albemarle County Community Development ph: 434.296.5832 x. 3432 From: Victoria Fort [mailto:vfortCcbrivanna.org] Sent: Thursday, June 13, 2013 5:14 PM To: 'Scott Collins' (scott(&collins -en_ ineering.com) Cc: Ellie Ray; Alex Morrison Subject: Westlake Hills Scott, RWSA has reviewed the Phase I Road Plans for the Westlake Hills Subdivision as prepared by Collins Engineering and dated 5/20/2013 and has the following comments: All Sheets: 1. Include all relevant items from the RWSA General Water and Sewer Notes (attached). 2. Label the RWSA sanitary sewer with ownership, size, and material (e.g. RWSA 15" VCP Sewer) 3. Include surveyed manhole inverts where applicable on plan sheets (e.g. CZI- MH -85). 4. In previous comments (see attached email), RWSA requested an additional 20' of right -of -way along the existing easement for the future upgrade of this sewer line. Please let me know if you'd like more information on this. Sheet 5: 1. Include RWSA's standard notes for a sewer connection: All connections to RWSA manholes shall be watertight and made with a flexible rubber boot. All coring methods, the coring contractor and all materials for construction shall be approved by RWSA in writing prior to construction. RWSA Engineering Staff shall be present for all cores into the manholes. Bypass pumping may be required at the sole discretion of RWSA staff. Grouting of the manhole bench or interior may be required, at the sole discretion of RWSA staff, for a smooth transition of flow. Existing manholes shall be backfilled to original grade to the satisfaction of RWSA. Contact RWSA Engineering a minimum of 3 business days in advance to schedule a core of a manhole. 2. RWSA would like to request an access easement from the property owner along the proposed 8" sewer. Sheet 12: 1. Verify that the inverts listed for existing RWSA CZI -MH -85 are surveyed (as -built data is not always accurate). 2. Include ownership (RWSA) on CZI- MH -85. 3. Include standard sewer connection notes on this sheet (see above). As mentioned previously, RWSA will require a flow acceptance for this project prior to approving site plans. Let me know if you have any questions about my comments. We would like to make one final review once plans have been revised, so please include us on your next submission. Thanks a lot, Victoria Victoria Fort, EIT Civil Engineer Rivanna Water and Sewer Authority 695 Moores Creek Lane Charlottesville, VA 22902 (P): (434) 977 -2970 ext. 205 (F): (434) 295 -1146