HomeMy WebLinkAboutSDP201300063 Review Comments Final Site Plan and Comps. 2014-02-08Albemarle County
Service Authority
TO: Ellie Ray
FROM: Alexander J. Morrison, EIT, Civil Engineer
DATE: February 2, 2014
RE: Site Plan Technical Review for: SDP201300063: Coles Import Specialists - Final Site
Plan
TMP# 04500 -00 -00 -100130
The below checked items apply to
this site.
✓ 1. This site plan is within the Authority's jurisdictional area for:
✓ A. Water and sewer
B. Water only
C. Water only to existing structure
D. Limited service
✓ 2. An 8 inch water line is located approximately 55' distance from this site plan.
3. Fire flow from, nearest public hydrant, located distant from this site plan, is
Gpm + at 20 psi residual.
✓ 4. An 8 inch sewer line is located approximately (on site).
5. An Industrial Waste Ordinance survey form must be completed.
✓ 6. No improvements or obstructions shall be placed within existing or future
easements.
7. and plans are currently under review.
8. and plans have been received and approved.
9. No plans are required.
10. Final water and sewer construction plans required for construction approval.
11. Final site plan may /may not be signed.
12. RWSA approval for water and /or sewer connections.
13. City of Charlottesville approval for sewer.
✓ Comments:
• Show existing 2 water meters (654 and 660) as a double tap off of the existing 8" DIP
watermain.
• Add label to existing 660 water meter: "5/8" W -Sf Residential - ACSA to size water meter for new
demand and use prior to approving building permit."
• Connection to public sanitary sewer system will incur connection fees. If water meter upsizing is
required it will incur additional connection fees.
• Add label to existing water service lateral (public side between water meter and 8" DIP
watermain): "Water meter upsizing may require water service lateral upsizing. If water meter
upsizing is required, the developer is required to determine the existing water service lateral size
and provide it to the ACSA for review. If water service lateral upsizing is required, the developer
must coordinate with the ACSA to upsize the water service lateral at the developer's expense."
168 Spotnap Road • Charlottesville • VA 22911 • Tel (434) 977 -4511 • Fax (434) 979 -0698
www.serviceauthoriy.org
Albemarle County
Service Authority
• Call out a backflow preventer on the private size of the water meter.
• Show existing easement around the water meter. If no easement exists, provide a new
easement which extends from the VDOT ROW and encompasses the water meter, 5' off sides
and back.
168 Spotnap Road • Charlottesville • VA 22911 • Tel (434) 977 -4511 • Fax (434) 979 -0698
www.serviceauthoriy.org