HomeMy WebLinkAboutARB201300183 Review Comments Preliminary Site Plan 2014-01-30ARCHITECTURAL REVIEW BOARD STAFF REPORT
Project # /Name
ARB- 2013 -183: Sonic Drive -thru at North Town Center
Review Type
Initial Site Plan/Preliminary ARB Review; Advisory Review for a Drive -thru Window
Parcel Identification
04500000011100
Location
Approximately 800' south of Carrsbrook Drive, on the east side of Route 29 North and the west side of Gander Drive,
adjoining the south side of StellarOne Bank
Zoned
Highway Commercial (HC), Entrance Corridor (EC)
Owner /Applicant
First Gold Leaf Land Trust, Wendell W. Wood Trustee /Collins Engineering (Scott Collins)
Magisterial District
Rio
Proposal
To construct a one story, 2,400 s.f restaurant building with associated parking, outdoor seating and drive- thru /drive-
in food service on 0.65 acres.
Context
The proposed development adjoins the southern boundary of the existing StellarOne bank property. The Gander
Mountain retail building, 450' to the south, is the only other building completed in the development. Smaller scale
commercial buildings, predating the EC, lie to the south, while the recently completed Rivanna Plaza Shopping
Center is located across Route 29 to the west.
Visibility
The north & south (side) and west (rear) elevations are expected to be visible.
ARB Meeting Date
February 3, 2014
Staff Contact
Brent Nelson
SITE /PROJECT HISTORY
DATE
APPLICATION /REVIEW TYPE
RESULT
04/17/2013
ARB 2013 -08, Gander Mountain, final site plan review
Approved
04/19/2013
ARB 2013 -1, Price Hyundai, initial site plan review, advisory SP review (vehicle display)
No objection with conditions
09/22/2008
ARB 2007 -10, Northtown Center, site plan amendment, phase 1
Approved
08/02/2006
ARB 2006 -34, Northtown Center, final site plan & building design review (StellarOne Bank)
Comments provide d
10/03/2005
ARB 2005 -112, Northtown Center, preliminary site plan review, advisory SP review
(StellarOne drive -thru, critical slopes)
SP: No objection
Site Plan: comments provided
02/25/2005
ARB 2005 -2, Northtown Center, preliminary site plan review, advisory SP reviews
(StellarOne drive -thru, pharmacy drive -thru, critical slopes)
SPs:Objections
Site Plan: comments provided
PROJECT INFORMATION
This review includes three closely related items: 1) initial site plan review, 2) preliminary site and architectural review, and 3) advisory review for a
Special Use Permit. The proposal includes a one story 2,400 s.f, building with a drive -thru window, outdoor seating with 3 tables and 16 canopy-
covered, drive -in food service parking spaces. The drive -thru window requires the Special Use Permit. The drive -thru lane is located between the rear of
the proposed building and the EC and along the south side of the proposed building. The majority of the parking spaces are located on the north side of
the building under the canopy. The front yard of the property, as viewed from the EC, is occupied by an approved stormwater management rain garden.
Staff had pre - application meetings with the applicant on October 28, 2013 and December 13, 2013. Issues regarding the site /building design and drive -
thru use were identified at both meetings. Issues identified in the first pre - application meeting included trademark architectural design features, the rear
wall ( "back of building ") orientation to the EC, visibility of the dumpster and mechanical equipment, the landscape proposal and visibility of the drive -
thru, excessive wall blankness, site/building lighting, window /door glass, signage and compatibility of materials, colors and compatibility with historic
architecture of the area. Issues identified in the second pre - application meeting included, but were not limited to, the continued rear wall ( "back of
building ") orientation to the EC, drive -thru visibility and the landscape proposal, window /door glass and continued excessive wall blankness.
ANALYSIS
REF
GUIDELINE
ISSUE
RECOMMENDATION
Structure design
1
The goal of the regulation of the design of development
Stone and brick are the primary materials
None
within the designated Entrance Corridors is to insure that
used to face the building. These materials
new development within the corridors reflects the
have a long history of use in local
traditional architecture of the area. Therefore, it is the
traditional and historic structures. The use
purpose of ARB review and of these Guidelines, that
of pilasters and stepped cornice has a
proposed development within the designated Entrance
historic precedent locally, as well.
Corridors reflect elements of design characteristic of the
significant historical landmarks, buildings, and structures
The building form is a basic brick
of the Charlottesville and Albemarle area, and to promote
rectangle with stone pilasters and narrow
orderly and attractive development within these corridors.
stone towers dividing the walls into bays,
Applicants should note that replication of historic structures
with canopies added as articulation. The
is neither required nor desired.
red brick and stone materials and pilaster
forms are reflective of previously approved
4
The examples contained in Appendix A should be used as
a guide for building design: the standard of compatibility
buildings in the EC and are expected to
with the area's historic structures is not intended to
help the building blend in to the Northtown
impose a rigid design solution for new development.
Center development.
Replication of the design of the important historic sites in
the area is neither intended nor desired. The Guideline's
standard of compatibility can be met through building
scale, materials, and forms which may be embodied in
architecture which is contemporary as well as traditional.
The Guidelines allow individuality in design to
accommodate varying tastes as well as special functional
requirements.
9
Building forms and features, including roofs, windows,
doors, materials, colors and textures should be compatible
with the forms and features of the significant historic
buildings in the area, exemplified by (but not limited to)
the buildings described in Appendix A [of the design
guidelines]. The standard of compatibility can be met
through scale, materials, and forms which may be
embodied in architecture which is contemporary as well as
traditional. The replication of important historic sites in
Albemarle County is not the objective of these guidelines.
5
It is also an important objective of the Guidelines to
Two brick colors are proposed for this
Provide building material and
establish a pattern of compatible architectural
building, an earthtone red and a shade of
color samples for review.
characteristics throughout the Entrance Corridor in order
gray. Brick is a frequently used material
to achieve unity and coherence. Building designs should
along this Entrance Corridor; however, the
Revise the proposal by limiting the
demonstrate sensitivity to other nearby structures within
proposed gray color is not a common color
use of the gray brick or eliminating
the Entrance Corridor. Where a designated corridor is
for this area.
it all together.
substantially developed, these Guidelines require striking
a careful balance between harmonizing new development
The proposed building is oriented with its
Revise the proposal to address the
with the existing character of the corridor and achieving
back wall and drive -thru stacking lane
continued back of building
compatibility with the significant historic sites in the area.
facing the EC. This is not reflective of the
majority of developments along the EC
appearance of the west (rear) and
north, south (side) elevations.
10
Buildings should relate to their site and the surrounding
context of buildings.
where the building fronts face the Corridor.
The orientation is not coordinated with the
Provide the needed articulation
without the use of overly -
11
The overall design of buildings should have human scale.
Scale should be integral to the building and site design.
adjacent bank building which faces the
Corridor or the Gander Mountain building
contrasting, horizontal brick bands
and non - transparent
12
Architecture proposed within the Entrance Corridor
should use forms, shapes, scale, and materials to create a
with its front elevation highly visible from
doors /windows. Remove the poster
cohesive whole.
the Corridor. The Rivanna Plaza
development across the EC to the west
display boards from the proposal.
13
Any appearance of "blankness" resulting from building
design should be relieved using design detail or
does include a drive -thru window on the
Provide an interior building floor
vegetation, or both.
north side of the northern building and a
drive -thru lane does pass along the EC side
plan.
15
Trademark buildings and related features should be
modified to meet the requirements of the Guidelines.
of the building.
Provide a site/building elevation,
as viewed from the EC, showing
The design of the west (rear), north and
the entire width of the site
south (side) elevations further emphasizes
including the canopies and
the "back door" orientation to the Corridor.
building.
The lack of windows and the contrasting
horizontal brick colors competing with the
repeating vertical pilasters results in an
uncoordinated, competitive appearance.
The poster display boards proposed in the
gray brick bands of the side elevations add
to the overly competitive design without
appropriately articulating the wall. The
poster boards would be considered signage
and are addressed later in this report.
The door and windows on the right (south)
end of the west (rear) elevation would be
highly visible. The drawings identify them
as metal panels instead of glass, although
discussioins in the pre - application meeting
indicated they would be glass. The metal
panels, though painted to coordinate with
the walls, emphasize the "back of
building" appearance. A floor plan would
help explain the relationship of interior
uses to the exterior design.
Two flat roofed canopies are proposed
above drive -in parking spaces. One canopy
adjoins the north building elevation and the
other is located across the travelway
adjacent to the bank property. While the
flat roof form, stepped cornice and cornice
color match that of the building, helping to
provide an integrated, cohesive
appearance, a site/building elevation, as
viewed from the EC, showing the canopies
and building would provide a better
understanding of the scale of the canopies
relative to the building and the site.
Several of the trademark Sonic design
features have been eliminated from the
proposal.
16
Window glass in the Entrance Corridors should not be
Details on the glass were not submitted.
Provide specs on the proposed
highly tinted or highly reflective. Window glass in the
glass. Ensure that the VLT shall
Entrance Corridors should meet the following criteria:
not drop below 40% and the VLR
Visible light transmittance (VLT) shall not drop below
shall not exceed 30 %.
40 %. Visible light reflectance (VLR) shall not exceed
30 %. Specifications on the proposed window glass should
be submitted with the applicationfiorfinal review.
Accessory structures and equipment
17
Accessory structures and equipment should be integrated
A dumpster enclosure is shown in the
Provide a dumpster enclosure
into the overall plan of development and shall, to the
southeast corner of the site and is not
detail on the site plan drawings. A
extent possible, be compatible with the building designs
expected to have much impact as viewed
brick wall enclosure, of the same
used on the site.
from the EC. A dumpster enclosure detail
should be provided. A brick wall
red brick in the building, would
provide a coordinated appearance.
18
The following should be located to eliminate visibility from
the Entrance Corridor street. If, after appropriate siting,
enclosure, of the same red brick in the
these features will still have a negative visual impact on the
building, would provide a coordinated
Revise the proposal by relocating
Entrance Corridor street, screening should be provided to
appearance.
all the rooftop units to the EC end
eliminate visibility.
of the roof and revising their
a. Loading areas,
Sheet A3.01 Exterior Elevations shows the
design so the top of the unit is
b. Service areas,
location of rooftop HVAC units, with a
below the top of the cornice.
c. Refuse areas,
dashed outline showing their height. The
d. Storage areas,
drawing also contains a note stating that no
Revise the site plan drawings by
e. Mechanical equipment,
mechanical equipment shall be visible
labeling all site features shown.
f. Above - ground utilities, and
from the EC; however, cross - sections
g. Chain link fence, barbed wire, razor wire, and similar
provided on Sheet 5 Site Cross - Sections
On Sheet 5 Site Cross - Sections,
security fencing devices.
(Section 1 in particular) suggest that some
of the units would be visible. The building
verify which of the cross sections
labeled "CROSS SECTION 2" is
19
Screening devices should be compatible with the design of
the buildings and surrounding natural vegetation and may
has a sloped roof as represented by the
actually Section 3 and revise the
consist of:
dashed line on the elevation drawing. The
drawing accordingly.
a. Walls,
roof is approximately 4' below the top of
b. Plantings, and
the cornice at the EC end and only 2'
c. Fencing.
below at the opposite end. Rooftop units
are located at both ends and in the middle
20
Surface runoff structures and detention ponds should be
designed to fit into the natural topography to avoid the need
of the roof. Relocating all the rooftop units
for screening. When visible from the Entrance Corridor
to the EC end and revising their design, if
street, these features must be fully integrated into the
needed, so the top of the unit is below the
landscape. They should not have the appearance of
top of the cornice would be appropriate.
engineered features.
Sheet 5 Site Cross - Sections has two
sections labeled "CROSS SECTION 2 ".
The section to the right appears to be
mislabeled and should be Section 3.
Some of the site features on Sheet 3 Layout
are not labeled on the drawing, so the need
for screening cannot be determined. These
features are mostly located along the drive -
thru lane.
The bio- retention "rain garden" facility,
located at the west (EC) end of the site,
was previously approved.
21
The following note should be added to the site plan and the
A similar wording to this note does appear
None
architectural plan: "Visibility of all mechanical equipment
on Sheets A 3.01 & A 3.02 Exterior
from the Entrance Corridor shall be eliminated."
Elevations.
Site development and layout
6
Site development should be sensitive to the existing
The overall site layout appears organized
Reduce the negative visual impact
natural landscape and should contribute to the creation of
and the building is parallel to the EC. The
of the drive -thru and its associated
an organized development plan. This may be
building is located farther from the EC
features, as viewed from the EC,
accomplished, to the extent practical, by reservin the
than than adjacent bank and Gander
by revising the planting plan to
trees and rolling terrain typical of the area; planting new
trees along streets and pedestrian ways and choosing
species that reflect native forest elements; insuring that
any grading will blend into the surrounding topography
thereby creating a continuous landscape; preserving, to the
extent practical, existing significant river and stream
valleys which may be located on the site and integrating
these features into the design of surrounding development;
and limiting the building mass and height to a scale that
does not overpower the natural settings of the site, or the
Entrance Corridor.
Mountain buildings due to the location of
the bio- retention "rain garden" facility.
The location of the drive -thru window and
the drive -thru lane, however, orients the
rear elevation of the building towards the
EC. The rear elevation, and the west ends
of the side elevations, do not have an
appropriate appearance due to the lack of
windows and the overly -busy appearance
of the brick bays. Because the drive -thru
location is directly related to the
appearance of the building, staff
reduce visibility of this area, and
redesign the rear and side
elevations to relieve the back door
appearance.
Staff anticipates a recommendation
of "no objection" on the special
use permit request when the
building articulation issues are
resolved.
See landscape recommendations,
39
The relationship of buildings and other structures to the
Entrance Corridor street and to other development within
recommends resolution of the architectural
below.
the corridor should be as follows:
articulation issues prior to making a
a. An organized pattern of roads, service lanes, bike paths,
positive recommendation on the Special
and pedestrian walks should guide the layout of the site.
Use Permit. A condition of the Special Use
b. In general, buildings fronting the Entrance Corridor
Permit could sufficiently address the
street should be parallel to the street. Building groupings
planting revisions needed, assuming
should be arranged to parallel the Entrance Corridor street.
confirmation on the ability to plant along
c. Provisions should be made for connections to adjacent
the sewer lines is confirmed.
pedestrian and vehicular circulation systems.
d. Open spaces should be tied into surrounding areas to
provide continuity within the Entrance Corridor.
e. If significant natural features exist on the site (including
creek valleys, steep slopes, significant trees or rock
outcroppings), to the extent practical, then such natural
features should be reflected in the site layout. If the
provisions of Section 32.5.6.n of the Albemarle County
Zoning Ordinance apply, then improvements required by
that section should be located so as to maximize the use of
existing features in screening such improvements from
Entrance Corridor streets.
f. The placement of structures on the site should respect
existing views and vistas on and around the site.
Site Grading
40
Site grading should maintain the basic relationship of the
Rough grading, associated with the orginal
None
site to surrounding conditions by limiting the use of
shopping center development, has leveled
retaining walls and by shaping the terrain through the use of
the site under review and stripped it of all
smooth, rounded land forms that blend with the existing
original vegetation. Stormwater runoff is
terrain. Steep cut or fill sections are generally unacceptable.
to be directed into the previously approved
Proposed contours on the grading plan shall be rounded with
bio- retention facility at the west (EC) end
a ten foot minimum radius where they meet the adjacent
of the site.
condition. Final grading should achieve a natural, rather than
engineered, appearance. Retaining walls 6 feet in height and
taller, when necessary, shall be terraced and planted to blend
with the landscape.
41
No grading, trenching, or tunneling should occur within the
drip line of any trees or other existing features designated
for preservation in the final Certificate of Appropriateness.
Adequate tree protection fencing should be shown on, and
coordinated throughout, the grading, landscaping and
erosion and sediment control plans.
42
Areas designated for preservation in the final Certificate
of Appropriateness should be clearly delineated and
protected on the site prior to any grading activity on the
site. This protection should remain in place until
completion of the development of the site.
43
Preservation areas should be protected from storage or
movement of heavy equipment within this area.
44
Natural drainage patterns (or to the extent required, new
drainage patterns) should be incorporated into the finished
site to the extent possible.
Landscaping
7
The requirements of the Guidelines regarding landscaping
The proposed landscape plan shows 5
Revise the Plant Schedule on Sheet
are intended to reflect the landscaping characteristic of
Willow Oaks, 35' on center maximum,
4 Landscape Plan to show all
many of the area's significant historic sites which is
with Yoshino Cherry trees interspersed,
shrub planting heights at 24"
characterized by large shade trees and lawns. Landscaping
adjacent to the EC right -of -way. Glossy
minimum. Include shrub plantings
should promote visual order within the Entrance Corridor
Abelia and Compact Burford Holly shrubs,
"IV" & "IS" in the schedule.
and help to integrate buildings into the existing
in groups of 5, are shown across the full
environment of the corridor.
width of the frontage, as well. This meets
the guideline requirement for EC frontage
Revise the drawing to show the
limits of the sanitary sewer
32
Landscaping along the frontage of Entrance Corridor
streets should include the following:
landscaping. The proposed heights at
easement beneath the Inkberry
a. Large shade trees should be planted parallel to the
planting for these shrubs, and several other
Holly shrubs. Replace the Inkberry
Entrance Corridor Street. Such trees should be at least 3'/2
shrubs in this proposal, are shown at 18" to
Holly shrubs with a mix of three
inches caliper (measured 6 inches above the ground) and
24 ". This does not meet the 24" guideline
evergreen shrub species, planted in
should be of a plant species common to the area. Such
requirement.
an informal, staggered
trees should be located at least every 35 feet on center.
arrangement and provide proof
b. Flowering ornamental trees of a species common to the
Proposed shrub plantings "IV" and "IS ",
that they would be allowed in that
area should be interspersed among the trees required by the
shown on the landscape plan, are not
easement. Show their planting
preceding paragraph. The ornamental trees need not
included in the plant schedule.
heights at 36" minimum.
alternate one for one with the large shade trees. They may be
planted among the large shade trees in a less regular spacing
The single row alone of inkberry holly
pattern.
shrubs shown along the EC side of the by-
c. In situations where appropriate, a three or four board
pass lane is not expected to sufficiently
fence or low stone wall, typical of the area, should align
mitigate the drive -thru appearance. Some
the frontage of the Entrance Corridor street.
of the shrubs are shown planted directly
d. An area of sufficient width to accommodate the
overtop the two riprap outfalls. A sanitary
foregoing plantings and fencing should be reserved
service line, for the bank to the north, is
parallel to the Entrance Corridor street, and exclusive of
shown underneath these shrubs. The
road right -of -way and utility easements.
associated easement line was not shown
and proof that these plantings would be
36
Landscaping of buildings and other structures:
a. Trees or other vegetation should be planted along the
allowed in that easement was not provided.
front of long buildings as necessary to soften the
A mix of three evergreen shrub species,
appearance of exterior walls. The spacing, size, and type
planted in an informal, staggered
of such trees or vegetation should be determined by the
arrangement, would be healthier and
length, height, and blankness of such walls.
provide a more substantial screen. A
b. Shrubs should be used to integrate the site, buildings,
minimum planting height of 36 would be
and other structures; dumpsters, accessory buildings and
appropriate.
structures; "drive thru" windows; service areas; and signs.
Shrubs should measure at least 24 inches in height.
35
Landscaping of parking areas:
Three large trees, 1 Allee Elm & 2 London
Revise Sheet 4 Landscaping Plan
a. Large trees should align the perimeter of parking areas,
Plane trees, are shown along the northern
by reducing the spacing of the 1
located 40 feet on center. Trees should be planted in the
edge of the parking area. Their spacing
Allee Elm & 2 London Plane trees,
interior of parking areas at the rate of one tree for every 10
exceeds the 40' maximum required. It
shown along the northern edge of
parking spaces provided and should be evenly distributed
appears that one additional large tree could
the site, to 40' maximum. Add
throughout the interior of the parking area.
be added if the spacing was reduced to 40'.
another large tree.
b. Trees required by the preceding paragraph should
measure 2'/z inches caliper (measured six inches above the
The outline of the parking canopy, shown
Include a dashed outline on the
ground); should be evenly spaced; and should be of a
on the site layout sheet, is not shown on
landscape plan showing the limits
species common to the area. Such trees should be planted
the landscape plan. The 2 London Plane
of the canopies. Clarify how the
in planters or medians sufficiently large to maintain the
trees appear to be only 3 to 4 feet from the
trees will be allowed to reach their
health of the tree and shall be protected by curbing.
canopy edge. It appears that the 11' 2" tall
natural form, without excessive
c. Shrubs should be provided as necessary to minimize the
canopy would interfere with the tree's
pruning, when planted so close to
parking area's impact on Entrance Corridor streets. Shrubs
natural form and require the excessive
the canopy.
should measure 24 inches in height.
38 Plant health:
The following note should be added to the landscape plan:
"All site plantings of trees and shrubs shall be allowed to
reach, and be maintained at, mature height; the topping of
trees is prohibited. Shrubs and trees shall be pruned
minimally and only to support the overall health of the
- -I_" "
22 Light should be contained on the site and not spill over
onto adjacent properties or streets;
23 Light should be shielded, recessed or flush - mounted to
eliminate glare. All fixtures with lamps emitting 3000
lumens or more must be full cutoff fixtures.
25 Light should have the appearance of white light with a
warm soft glow; however, a consistent appearance
throughout a site or development is required.
pruning the guidelines discourage. How
this potential conflict would be addressed
was not indicated in this submission.
Only one large tree, an Allee Elm, is
shown along the southern edge of the
parking area. Five Little Gem Magnolias, 1
Serviceberry and 5 Nellie Stevens Hollies
are proposed where other large trees could
have been planted. These smaller trees are
expected to provide more screening of the
drive -thru, making them a logical
substitute. There appears to be room for
another large tree in the planting island
immediately east of the dumpster
enclosure. All of these plantings appear to
be in an existing sanitary sewer easement.
Proof that they would be permitted in that
easement was not provided. If the trees are
not permitted in the easement, the planting
area should be increased to accommodate
the trees.
This note is located on Sheet 4 Landscape
Plan.
Sheet 3 Layout shows 2 pole lights at the
west end of the site adjacent to the by -pass
lane. A lighting plan was not provided for
review. Details regarding canopy lighting
were not provided. Canopy lighting should
be flush -mount or recessed. Sheets A3.01
& A3.02 Exterior Elevations show down
lights at the top of the restaurant walls
Add another large tree in the
planting island immediately east of
the dumpster enclosure (south end
of the site) and provide proof that
all the proposed plantings along
the southern boundary are
permitted in the sanitary sewer
easement. If the trees aren't
permitted, increase the planting
area.
None
Provide a complete lighting plan
for review. All wall and site lights
shall be full cutoff fixtures.
Canopy lights shall be flush -mount
or recessed. Wall lights shall be
down lights only and located so as
to illuminate the sidewalk without
over - illuinating the building.
10
II
Consequently, if existing lamps that emit non -white light
while the rendered elevations show
are to remain, new lamps may be required to match them.
up /down lights approximately half -way up
the wall. In past reviews, the ARB has
26
Dark brown, dark bronze, or black are appropriate colors
for free - standing pole mounted light fixtures in the
indicated that wall lights should be
Entrance Corridors.
mounted to light the walkway without
over - illuminating the building.
27
The height and scale of freestanding, pole - mounted light
fixtures should be compatible with the height and scale of
the buildings and the sites they are illuminating, and with
the use of the site. Typically, the height of freestanding
pole - mounted light fixtures in the Entrance Corridors
should not exceed 20 feet, including the base. Fixtures that
exceed 20 feet in height will typically require additional
screening to achieve an appropriate appearance from the
Entrance Corridor.
28
In determining the appropriateness of lighting fixtures for
the Entrance Corridors, the individual context of the site
will be taken into consideration on a case by case basis.
29
The following note should be included on the lighting
The note does not appear on any of the
Include the standard lighting note
plan: "Each outdoor luminaire equipped with a lamp that
drawings in this application.
on the lighting plan.
emits 3,000 or more initial lumens shall be a fill cutoff
luminaire and shall be arranged or shielded to reflect light
away from adjoining residential districts and away from
adjacent roads. The spillover of lighting from luminaires
onto public roads and property in residential or rural areas
zoning districts shall not exceed one half footcandle."
24
Light levels exceeding 30 footcandles are not appropriate
The ARB, in reviewing other applications
Provide a lighting plan that limits
for display lots in the Entrance Corridors. Lower light
with canopies, has indicated that limiting
canopy illumination levels to 20
levels will apply to most other uses in the Entrance
canopy illumination levels to 20
footcandles.
Corridors.
footcandles is appropriate.
Signs
9b
Channel lettering (mounted on a raceway or individual
Wall signs are shown on the elevation line
Separate applications for signs are
letters) is preferred to cabinet signs because cabinet signs
drawings and renderings. A separate
required. The sign type is
tend to appear less integrated with the building. Channel
application & review is required for signs;
appropriate; however, overly
letters overlay the wall material and allow the structure of
however, staff recommends ARB input on
intense sign colors will not be
the building to "read through" with less interruption. This
the illustrated design. ARB Sign
approved and illumination will be
results in a more coordinated overall appearance.
Guidelines encourage the use of channel
limited to internal illumination of
letters (without a backer panel) as they
the channel letter text with no
overlay the wall material, allowing the
illumination of the backer panel.
II
SUMMARY OF RECOMMENDATIONS
Staff recommends the following as the primary points of discussion:
1. The proposal's back door orientation to the Entrance Corridor.
2. The "back door" appearance and articulation of the side and rear elevations of the building, and the lack of windows.
3. Visibility of rooftop equipment.
4. Visibility of the drive -thru and its associated features.
5. The relationship of the drive -in canopies to the building and landscaping.
6. Proposed building materials & brick colors.
7. The proposed Sonic wall signs and the use of wall poster display boards.
Regarding the for the Special Use Permit for the Drive -thru Window:
Staff recommends that the ARB not forward a recommendation of "no objection" to the Planning Commission until the following issues have been
adequately addressed:
1. Relieve the inappropriate back door appearance of the rear elevation and the west ends of the side elevations that results from the lack of
windows and the overly -busy appearance of the brick bays.
12
structure of the building to read through
with less interruption. The applicant is
Remove the poster display boards
proposing channel letters on a backer
from the proposal.
panel. The backer panel is the Sonic speed -
of -sound trademark/graphic. It has an
integrated, coordinated appearance with
the "SONIC" channel letters. The sign size
is appropriate for the wall area and the sign
location is coordinated with the
architecture. Details regarding the exact
colors proposed and the type of
illumination were not provided. Overly
intense colors are discouraged by the sign
guidelines and internal illumination of the
text only would be appropriate.
The poster display boards proposed on the
side elevations are signage and do not meet
the above -noted guideline encouraging a
sign type that allows the building structure
to "read through ".
SUMMARY OF RECOMMENDATIONS
Staff recommends the following as the primary points of discussion:
1. The proposal's back door orientation to the Entrance Corridor.
2. The "back door" appearance and articulation of the side and rear elevations of the building, and the lack of windows.
3. Visibility of rooftop equipment.
4. Visibility of the drive -thru and its associated features.
5. The relationship of the drive -in canopies to the building and landscaping.
6. Proposed building materials & brick colors.
7. The proposed Sonic wall signs and the use of wall poster display boards.
Regarding the for the Special Use Permit for the Drive -thru Window:
Staff recommends that the ARB not forward a recommendation of "no objection" to the Planning Commission until the following issues have been
adequately addressed:
1. Relieve the inappropriate back door appearance of the rear elevation and the west ends of the side elevations that results from the lack of
windows and the overly -busy appearance of the brick bays.
12
2. Revise the landscape plan to show the limits of the sanitary sewer easement beneath the row of Inkberry Holly shrubs. Replace the Inkberry
Holly shrubs with a mix of three evergreen shrub species, planted in an informal, staggered arrangement, and provide proof that they would be
allowed in that easement. If they aren't allowed, increase the planting area. Show their planting heights at 36" minimum.
3. Provide proof that all the proposed plantings along the southern boundary are permitted in the sanitary sewer easement.. If the trees aren't
permitted, increase the planting area.
Staff offers the following comments on the preliminary proposal:
1. Provide building material and color samples for review.
2. Revise the proposal by limiting the use of the gray brick or eliminating it all together.
3. Revise the proposal to address the continued excessive back of building appearance of the west (rear) and north, south (side) elevations. Provide
the needed articulation without the use of overly contrasting, horizontal brick bands and non - transparent doors /windows. Remove the poster
display boards from the proposal.
4. Provide an interior building floor plan.
5. Provide a site/building elevation, as viewed from the EC, showing the entire width of the site including the canopies and building.
6. Provide specs on the proposed glass. Ensure that the VLT shall not drop below 40% and the VLR shall not exceed 30 %.
7. Provide a dumpster enclosure detail on the site plan drawings. A brick wall enclosure, of the same red brick in the building, would provide a
coordinated appearance.
8. Revise the proposal by relocating all the rooftop units to the EC end of the roof and revising their design so the top of the unit is below the top of
the cornice.
9. Revise the site plan drawings by labeling all site features shown. On Sheet 5 Site Cross - Sections, verify which of the cross sections labeled
"CROSS SECTION 2" is actually Section 3 and revise the drawing accordingly.
10. Reduce the negative visual impact of the drive -thru and its associated features, as viewed from the EC, by revising the planting plan to reduce
visibility of this area and redesign the rear and side elevations to relieve the back door appearance.
11. Revise the Plant Schedule on Sheet 4 Landscape Plan to show all shrub planting heights at 24" minimum. Include shrub plantings "IV" & "IS"
in the schedule.
12. Revise the drawing to show the limits of the sanitary sewer easement beneath the Inkberry Holly shrubs. Replace the Inkberry Holly shrubs with
a mix of three evergreen shrub species, planted in an informal, staggered arrangement and provide proof that they would be allowed in that
easement. Show their planting heights at 36" minimum.
13. Revise Sheet 4 Landscaping Plan by reducing the spacing of the 1 Allee Elm & 2 London Plane trees, shown along the northern edge of the site,
to 40' maximum. Add another large tree.
14. Include a dashed outline on the landscape plan showing the limits of the canopies. Clarify how the trees will be allowed to reach their natural
form, without excessive pruning, when planted so close to the canopy.
15. Add another large tree in the planting island immediately east of the dumpster enclosure (south end of the site) and provide proof that all the
proposed plantings along the southern boundary are permitted in the sanitary sewer easement. If trees aren't permitted, increase the planting area.
16. Provide a complete lighting plan for review. All wall and site lights shall be full cutoff fixtures. Canopy lights shall be flush -mount or recessed.
Wall lights shall be down lights only and located so as to illuminate the sidewalk without over - illuminating the building.
17. Include the standard lighting note on the lighting plan.
18. Provide a lighting plan that limits canopy illumination values to 20 footcandles.
13
19. Separate applications for signs are required. The sign type is appropriate; however, overly intense sign colors will not be approved and
illumination will be limited to internal illumination of the channel letter text with no illumination of the backer panel.
20. Remove the poster display boards from the proposal.
Staff offers the following comments on the Initial Site Plan:
Staff recommends that the ARB forward the following recommendations to the agent:
Regarding requirements to satisfy the design guidelines as per § 18- 30.6.4(2), (3) and (5):
o As per § 32.4.2.2(b)(3) and 30.6.4(c)(3) and EC Guidelines 35a and 36b, it is not clear that sufficient planting area is available along
thenorth side of the parking lot to accommodate trees at 21/2" caliper, 40' on center; or along the south side of the parking lot (drive -thru
travelway) to accommodate shrubs and trees at 21 /z" caliper, 40' on center; or that sufficient planting area is available to accommodate shrubs
along the western edge of the drive -thru to mitigate the appearance of the drive -thru use and its associated site features.
• Regarding recommendations on the plan as it relates to the guidelines:
o See comments on the preliminary proposal.
• Regarding recommended conditions of initial site plan approval:
• A Certificate of Appropriateness is required prior to final site plan approval.
• Clarify how the trees along the north edge of the parking lot will be allowed to reach their natural form, without excessive pruning, when
planted so close to the canopy.
• Provide proof that all the proposed tree and shrub plantings along the southern boundary of the parking lot and shrubs along the western edge
of the travelway are permitted in the sanitary sewer easements at both locations.
• Regarding conditions to be satisfied prior to issuance of a grading permit:
o None
14
TABLE A
This report is based on the following submittal items:
Sheet #
Drawing Name
Drawing Date /Revision Date
Site Plan
1
Cover Sheet
12/20/2103
2
Existing Conditions
12/20/2013
3
Layout
12/20/2013
4
Landscaping Plan
12/20/2013
5
Site Cross - Sections
12/20/2013
6
Existing Stormwater Management Plan
12/20/2013
Architectural Plans
A3.01
Exterior Elevations
12/19/2013
A3.02
Exterior Elevations
12/19/2013
Material /Color
Samples
None
15