HomeMy WebLinkAboutSDP201300055 Review Comments Initial Site Plan 2013-10-18�pF A
vt�r�1Q
COUNTY OF ALBEMARLE
Department of Community Development
401 McIntire Road, Room 227
Charlottesville, Virginia 22902 -4596
Phone (434) 296 -5832 Fax (434) 972 -4126
Project: Stonewater Townhomes - Initial
Plan preparer: Collins Engineering [434- 293 -3719]
Owner or rep.: Marvin & Carolyn Spencer
Plan received date: 7 Oct 2013
Date of comments: 17 Oct 2013
Reviewer: Michelle Roberge
Engineering has completed the review of application SDP201300055. Please see the following comments.
A. Site Development Plan (SDP201300055)
1) Verify with VDOT if warrants are met to design and install the signal at Rio Rd and Penn Park
Lane to satisfy Treesdale Park proffer.
2) The sidewalk to the townhomes along Treesdale Way and Stonehenge Way is not uniform
throughout the entire length. It jogs out, then crosses over medians between each lot. Show
sidewalk to tie into sidewalk from Penfield Lane.
3) Clarify what will be in the median between each lot.
4) Please note that a subdivision plat is required to subdivide the lots as shown on plan. The
approved plat from SUB2007 -77 shows this area as Block A and Block B only.
5) There is an existing overhead electric line running through the proposed development. Clarify
the new location of electric line since it will be an obstruction when townhomes are built.
6) Show CG -12 near lots 41 an 42 from Penfield Lane.
7) Some existing items need to be shown or removed. Address the following:
a) Show existing sidewalk along Treesdale Way and Stonehenge Way, just across
proposed townhomes.
b) A portion of fence across Stonehenge Way near lot 47 has been removed. Please
remove on plans.
c) There is a retaining wall south of building in the Treesdale development. Show wall
and include existing grading between Treesdale and this development. See WP02011-
88 since the proposed contours now appear to be existing. The proposed swale for
townhomes at this area will change slightly to tie to existing contours.
Engineering Review Comments
Page 2 of 2
8) A WPO application shall be submitted for the proposed townhomes. The county records show
that the most current approved WPO application is WPO2012 -73 (StonewaterSubdivision), but
E &S measures for the proposed townhomes are not included since it was considered future
development. Also, it appears from WP02010- 11(Treesdale Park), a portion of the townhomes
development is not draining to the enhanced extended detention pond. Please clarify in WPO
application.
Sincerely,
Michelle Roberge