HomeMy WebLinkAboutARB201300179 Review Comments Final Site Plan and Comps. 2014-01-30ARCHITECTURAL REVIEW BOARD STAFF REPORT
Project #/Name
ARB- 2013 -179: 5th Street Development
Review Type
Preliminary Review of a Site Development Plan; Advisory Review for a Drive -thru Window
Parcel Identification
076000000055A0, 76M1000000100
Location
On the southeast side of 5th Street, south of Moores Creek, northwest of the Holiday Inn and north of I64
Zoned
Highway Commercial (HC), Entrance Corridor (EC)
Owner /Applicant
FTV Investments LLC /Piedmont Development (Katurah Roell)
Magisterial District
Scottsville
Proposal
To construct one of three commercial/retail buildings with associated site improvements, including a drive -thru
window, which requires a Special Use Permit.
Context
The site is located in an area of mixed development. Hotels are located to the south and northwest. Residential
development is located to the southeast and northeast. The Christian Aid Mission is located to the west. Moore's
Creek and Biscuit Run border the site on the north and east. The border between the County and the City of
Charlottesville is located just to the north.
Visibility
From the 5th Street Entrance Corridor, the north, east and west elevations of Building A will be visible, the north and
east elevations of Building B will be visible, and Building C may be visible at a distance. Visibility from the 164
Entrance Corridor is limited due to trees in the right -of -way.
ARB Meeting Date
February 3, 2014
Staff Contact
Margaret Maliszewski
SITE HISTORY
ARB applications were previously submitted for Cracker Barrel and Texas Roadhouse restaurants at this site, but they were indefinitely
deferred or withdrawn by the applicants. A pre - application conference was held on October 28, 2013 for this proposal and preliminary EC
comments were provided at that time. (See Attachment A.) A Special Use Permit application has been submitted for a drive -thru window
associated with Building A in the current proposal. An amendment to the approved proffers and application plan for the 1999 rezoning of
this property is also under review.
ANALYSIS
REF
GUIDELINE
ISSUE
RECOMMENDATION
Structure design
1
The goal of the regulation of the design of development
The proposed building uses brick as a
Revise the architectural
within the designated Entrance Corridors is to insure that new
primary material, but has no other
design to better reflect the
development within the corridors reflects the traditional
particular connection to local historic
traditional architecture of
architecture of the area. Therefore, it is the purpose of ARB
architecture or to nearby buildings. It
the area.
review and of these Guidelines, that proposed development
follows a standard strip shopping center
within the designated Entrance Corridors reflect elements of
format with minimal references to
Revise the architectural
design characteristic of the significant historical landmarks,
traditional commercial architecture: the
design to provide
buildings, and structures of the Charlottesville and Albemarle
area, and to promote orderly and attractive development
front elevation is divided by pilasters into
additional detailing and
within these corridors. Applicants should note that replication
bays and the bays are composed of a sign
better proportions above
of historic structures is neither required nor desired.
band above an awning above storefront
windows. In this case, the sign band is
the awnings and to
eliminate the appearance of
3
New structures and substantial additions to existing structures
should respect the traditions of the architecture of historically
EIFS, there is no detailing above the
an overscaled sign band.
significant buildings in the Charlottesville and Albemarle
band, and the band appears overscaled.
area. Photographs of historic buildings in the area, as well as
Pilasters are identified as "Harvard Brik"
Provide material and color
drawings of architectural features, which provide important
which is a structural veneer product.
samples for review.
examples of this tradition are contained in Appendix A.
Pilasters have a cast stone sill and a rock -
face block base. Material and color
Provide additional detail to
4
The examples contained in Appendix A should be used as a
guide for building design: the standard of compatibility with
samples have not been submitted.
break -up the blankness of
the area's historic structures is not intended to impose a rigid
the side elevation bays.
design solution for new development. Replication of the
design of the important historic sites in the area is neither
On the side elevations, EIFS is proposed
intended nor desired. The Guideline's standard of
for wall surfaces between the pilasters.
compatibility can be met through building scale, materials,
The "back" half of the side elevations are
and forms which may be embodied in architecture which is
contemporary as well as traditional. The Guidelines allow
blank EIFS walls.
individuality in design to accommodate varying tastes as well
asspecial functional requirements.
9
Building forms and features, including roofs, windows,
doors, materials, colors and textures should be compatible
with the forms and features of the significant historic
buildings in the area, exemplified by (but not limited to) the
buildings described in Appendix A [of the design guidelines].
The standard of compatibility can be met through scale,
materials, and forms which may be embodied in architecture
which is contemporary as well as traditional. The replication
of important historic sites in Albemarle County is not the
objective of these guidelines.
10
Buildings should relate to their site and the surrounding
context of buildings.
11
The overall design of buildings should have human scale.
Scale should be integral to the building and site design.
13
Any appearance of "blankness" resulting from building
design should be relieved using design detail or vegetation, or
both.
16
Window glass in the Entrance Corridors should not be highly
No information on glass has been
Provide specs on the
tinted or highly reflective. Window glass in the Entrance
submitted.
proposed window glass
Corridors should meet the following criteria: Visible light
confirming that visible
transmittance (VLT) shall not drop below 4001o. Visible light
light transmittance shall
reflectance (VLR) shall not exceed 30% Specifications on the
not drop below 40% and
proposed window glass should be submitted with the
visible light reflectance
application for final review.
shall not exceed 30 %.
Accessory structures and equipment
17
Accessory structures and equipment should be integrated into
Parapet walls are proposed to screen
Provide a dumpster screen
the overall plan of development and shall, to the extent
rooftop equipment from view. A wooden
detail in the plan.
possible, be compatible with the building designs used on the
fence with shrubs is proposed to screen
site.
the dumpster, although no fence detail
appears in the plan.
Show the rooftop
equipment on the elevation
18
The following should be located to eliminate visibility from the
Entrance Corridor street. If, after appropriate siting, these
drawings to confirm that
features will still have a negative visual impact on the Entrance
visibility will be
Corridor street, screening should be provided to eliminate
eliminated.
visibility. a. Loading areas, b. Service areas, c. Refuse areas,
d. Storage areas, e. Mechanical equipment, f. Above - ground
utilities, and
g. Chain link fence, barbed wire, razor wire, and similar
security fencing devices.
19
Screening devices should be compatible with the design of
the buildings and surrounding natural vegetation and may
consist o£ a. Walls, b. Plantings, and c. Fencing.
Lighting
Lighting details haven't been provided, but wall
Provide complete lighting information for review. Eliminate
lights are shown on the building.
up- lighting from the wall lights.
Landscaping
6
Site development should be sensitive to the existing natural
3' /z" Scarlet Oaks are proposed 35 -40' on
Clearly show all utilities
landscape and should contribute to the creation of an
center along the 5th Street EC frontage.
and easements on the
organized development plan. This may be accomplished, to
Dogwoods alternate with the Oaks and a
landscape plan. Increase
the extent practical, by preserving the trees and rolling terrain
row of Inkberry Holly is also proposed.
planting area to avoid
typical of the area; planting new trees along streets and
A sewer line runs along the frontage, but
planting and utility
pedestrian ways and choosing species that reflect native
no sewer easement is shown. It appears
conflicts without reducing
forest elements; insuring that any grading will blend into the
surrounding topography thereby creating a continuous
that there is a conflict between
the amount of landscaping
landscape; preserving, to the extent practical, existing
landscaping and utilities that must be
proposed.
significant river and stream valleys which may be located on
resolved to meet the EC Guidelines.
the site and integrating these features into the design of
Increasing the planting area may be
Increase the number of
surrounding development; and limiting the building mass and
required.
shrub species proposed so
height to a scale that does not overpower the natural settings
that the number of shrubs
of the site, or the Entrance Corridor.
Only a single shrub species is proposed
on site. Increasing the number of species
proposed for any one
species does not exceed
8
Continuity within the Entrance Corridor should be obtained
by planting different types of plant materials that share
could help ensure the health of the
25% of the total number of
similar characteristics. Such common elements allow for
landscape.
shrubs proposed.
more flexibility in the design of structures because common
landscape features will help to harmonize the appearance of
The plant schedule lists 61 Inkberry
Coordinate the plant
development as seen from the street upon which the Corridor
is centered.
Holly, but the plan shows 71.
schedule and the plan
regarding the number of
32
Landscaping along the frontage of Entrance Corridor streets
should include the following:
Inkberry Holly shown.
a. Large shade trees should be planted parallel to the
Entrance Corridor Street. Such trees should be at least 3'/2
inches caliper (measured 6 inches above the ground) and
should be of a plant species common to the area. Such trees
should be located at least every 35 feet on center.
b. Flowering ornamental trees of a species common to the area
should be interspersed among the trees required by the
preceding paragraph. The ornamental trees need not alternate
one for one with the large shade trees. They may be planted
among the large shade trees in a less regular spacing pattern.
c. In situations where appropriate, a three or four board fence
or low stone wall, typical of the area, should align the
frontage of the Entrance Corridor street.
d. An area of sufficient width to accommodate the foregoing
plantings and fencing should be reserved parallel to the
Entrance Corridor street, and exclusive of road right -of -way
and utility easements.
33
Landscaping along interior roads:
Allee Elms are proposed along the
Clearly show all utilities
a. Large trees should be planted parallel to all interior roads.
entrance drive, but a number of utilities
and easements on the
Such trees should be at least 2%2 inches caliper (measured six
cross through the area.
landscape plan. Increase
inches above the ground) and should be of a plant species
planting area to avoid
common to the area. Such trees should be located at least
planting and utility
every 40 feet on center.
conflicts without reducing
35
Landscaping of parking areas:
The south side of the parking lot (aligned
the amount of landscaping
a. Large trees should align the perimeter of parking areas,
with Biscuit Run) is adjacent to on -site
proposed.
located 40 feet on center. Trees should be planted in the
wooded area and stream buffer. The west
interior of parking areas at the rate of one tree for every 10
side of the parking lot is adjacent to a
parking spaces provided and should be evenly distributed
property line and off -site wooded area.
throughout the interior of the parking area.
Trees and shrubs are not provided along
b. Trees required by the preceding paragraph should measure
these parking lot perimeters. However, a
2'/2 inches caliper (measured six inches above the ground);
rain garden is proposed and some interior
should be evenly spaced; and should be of a species common
parking lot trees are provided near the
to the area. Such trees should be planted in planters or
perimeters. It is anticipated that the on- and
medians sufficiently large to maintain the health of the tree
off -site wooded areas and proposed trees
and shall be protected by curbing.
c. Shrubs should be provided as necessary to minimize the
are sufficient in lieu of the perimeter trees
parking area's impact on Entrance Corridor streets. Shrubs
on these sides of the parking lot.
should measure 24 inches in height.
Interior parking lot trees are provided in
sufficient numbers; however, various
utilities cross the site and appear to conflict
with much of the proposed planting.
Development pattern
14
Arcades, colonnades, or other architectural connecting
Building A is oriented parallel to the EC,
Include elevations for
devices should be used to unify groups of buildings within a
with the front elevation facing the road.
Buildings B and conceptual
development.
Buildings B and C are not oriented
parallel to the EC. What appears to be the
elevations for Building C
with the next ARB
39
The relationship of buildings and other structures to the
Entrance Corridor street and to other development within the
front of Building B is angled toward the
submittal.
corridor should be as follows:
5th 5 Street EC. What appears to be the
a. An organized pattern of roads, service lanes, bike paths,
and pedestrian walks should guide the layout of the site.
front of Building C is oriented toward the
Staff recommends that the
b. In general, buildings fronting the Entrance Corridor street
south side of Building B. Buildings B
ARB forward a
should be parallel to the street. Building groupings should be
and C will have less impact on the EC (if
recommendation of "no
arranged to parallel the Entrance Corridor street.
their height does not exceed that of
objection" to the Planning
c. Provisions should be made for connections to adjacent
Building A) due to their greater distance
Commission on the request
pedestrian and vehicular circulation systems.
from it, and their position partially
for the drive -thru use,
d. Open spaces should be tied into surrounding areas to
behind other buildings, but they will still
based on the layout and
provide continuity within the Entrance Corridor.
be visible.
landscaping in the
e. If significant natural features exist on the site (including
12/9/2013 plan.
creek valleys, steep slopes, significant trees or rock
The building arrangement is part of the
outcroppings), to the extent practical, then such natural
proposed rezoning amendment. A related
Staff recommends the ARB
features should be reflected in the site layout. If the
provisions of Section 32.5.6.n of the Albemarle County
proffer states that all buildings will be
forward the following
Zoning Ordinance apply, then improvements required by that
oriented towards the EC. The position of
recommendation to the PC
section should be located so as to maximize the use of
Building C does not meet this proffer.
regarding the proposed
existing features in screening such improvements from
Screening plants along the property line
amendment to the
Entrance Corridor streets.
west of Building C, if free of utilities and
rezoning: With appropriate
f. The placement of structures on the site should respect
easements, could further limit the impact
landscaping along the
existing views and vistas on and around the site.
of Building C on the 5th Street EC.
property line west of
Building C, Building C
Building A is proposed as an initial phase
need not be oriented to 5th
of development, and architectural designs
Street.
have not been provided for Buildings B
and C. Historically, the ARB has not
granted final site plan approval without
review and approval of the architecture
for all proposed buildings. Elevations for
Building B and conceptual level
elevations for Building C should be
submitted for review.
A drive -thru window is proposed on the
east elevation of Building A. It is a
simple pick -up window below an
awning. The wall area immediately
around the window and awning is faced
with Harvard Brik. The site layout
provides for vehicles stacking behind the
building, away from the 5th Street EC,
and trees are provided in an island next to
the drive -thru lane. These features are
expected to sufficiently limit visual
impacts of the drive -thru use on the EC.
Site Grading
40
Site grading should maintain the basic relationship of the site to
15' retaining walls are proposed on the
None.
surrounding conditions by limiting the use of retaining walls
south and east sides of the site and are
and by shaping the terrain through the use of smooth, rounded
not expected to be visible from the 5th
land forms that blend with the existing terrain. Steep cut or fill
Street EC. The walls are not expected to
sections are generally unacceptable. Proposed contours on the
be visible from I64 due to topography
grading plan shall be rounded with a ten foot minimum radius
and on- and off -site wooded area.
where they meet the adjacent condition. Final grading should
achieve a natural, rather than engineered, appearance. Retaining
walls 6 feet in height and taller, when necessary, shall be
terraced and planted to blend with the landscape.
41
No grading, trenching, or tunneling should occur within the
There is existing wooded area to remain
Clarify on the plans the
drip line of any trees or other existing features designated for
on site, but it is not clearly shown on the
wooded area to remain and
preservation in the final Certificate of Appropriateness.
plans.
show tree protection
Adequate tree protection fencing should be shown on, and
fencing.
coordinated throughout, the grading, landscaping and erosion
and sediment control plans.
42
Areas designated for preservation in the final Certificate of
Appropriateness should be clearly delineated and protected
on the site prior to any grading activity on the site. This
protection should remain in place until completion of the
development of the site.
43
Preservation areas should be protected from storage or
movement of heavy equipment within this area.
SIGNS
Basic representations of signs are shown in the sign bands, but no details are
provided and no comprehensive sign plan has been submitted.
Submit a comprehensive sign
plan with the next ARB submittal.
SUMMARY OF RECOMMENDATIONS
Staff recommends the following as the pritriga points of discussion:
1. The design of Building A: relationship to local historic architecture and nearby buildings; proportions /detailing of the sign band
2. Building materials and colors — the Harvard Brik and EIFS
3. Landscaping and utilities
4. The location and design of the drive -thru
5. Buildings B and C: visibility, orientation to 5th Street, expectations for future review
Regarding the request for the Special Use Permit for the Drive -thru Window, staff recommends that the ARB forward the following
recommendation to the Planning Commission:
The ARB has no objection to the proposed drive -thru use based on the layout and landscaping in the plan dated 12/9/13.
Regarding the request for the Amendment to the Rezoning, staff recommends that the ARB forward the following recommendation to the
Planning Commission:
With appropriate landscaping along the property line west of Building C, Building C need not be oriented to 5th Street.
Regarding the preliminary site and architectural proposal, staff offers the following comments:
1. Revise the architectural design of Building A to reflect the traditional architecture of the area.
2. Revise the architectural design of Building A to provide additional detailing and better proportions above the awnings. Avoid the
appearance of an overscaled sign band.
3. Provide material and color samples for review.
4. Provide additional detail to break -up the blankness of the side elevation bays of Building A.
5. Provide specs on the proposed window glass for Building A confirming that visible light transmittance shall not drop below 40% and
visible light reflectance shall not exceed 30 %.
6. Provide a dumpster screen detail in the plan.
7. Provide complete lighting information for review. Eliminate up- lighting from the wall lights.
8. Clearly show all utilities and easements on the plan.
9. Increase planting area to avoid planting and utility conflicts without reducing the amount of landscaping proposed.
10. Increase the number of shrub species proposed so that the number of proposed shrubs for any one species is limited to 25% of the total
number of shrubs proposed.
11. Coordinate the plant schedule and the plan regarding the number of Inkberry Holly shown.
12. Include elevations for Buildings B and conceptual elevations for Building C with the next ARB submittal.
13. Clarify on the plans the wooded area to remain and show tree protection fencing.
14. Submit a comprehensive sign plan with the next ARB submittal.
TABLE A This report is based on the following submittal items:
Sheet #
rawing Name
Drawing Date /Revision Date
1
Cover
12/9/13
2
Exiting Conditions & Demolition Plan
12/9/13
3
1 Layout Plan
12/9/13
4
Lighting Plan
12/9/13
5
Utilities Plan
12/9/13
6
Grading & Drainage Plan
12/9/13
7
Site Sections
12/9/13
SK -1
Exterior Elevations — North and East (black & white and color)
11 -12 -13
-
Site photos
-
ATTACHMENT A
5t" Street Development: 10/28/2013 Pre - Application Meeting — EC comments
Check utilities for landscape coordination. Planting area may need to be increased to meet ARB landscape requirements. Planting must
be clear of utilities and easements.
Is the material that is rendered as brick, real brick, or is it EIFs colored and patterned to look like brick? If the latter, recommend revise
to real brick.
The wall area above the awnings needs more detailing, better proportions. As currently illustrated, it looks like a billboard.
All equipment (rooftop and ground- mounted) must be positioned to not be visible from the EC. This should not result in a parapet that
looks over - scaled.
Generally, the building needs additional detailing.
The center bay of the fagade could use further divisions.
Architecturally, what is the connection to the historic architecture of the county?
Interior parking lot trees will be required, in addition to perimeter parking lot trees.
Pole light height, includes bases, shall not exceed the height of the building and shall not exceed 20'.
Eliminate up- lighting from the wall lights.
Submit sign design criteria for review with the ARB application. Comprehensive sign criteria will need to be approved before final ARB
approval is given for the building and site.
The ARB will review the initial site plan. ARB approval is required prior to final site plan approval.
10