Loading...
HomeMy WebLinkAboutSDP201400010 Review Comments Final Site Plan and Comps. 2014-02-27i" ,. `IRGINZP COUNTY OF ALBEMARLE Department of Community Development 401 McIntire Road, Room 227 Charlottesville, Virginia 22902 -4596 Phone (434) 296 -5832 Fax (434) 972 -4126 Project: Final Site Plan for Rolkin Road Retail Center - SDP201400010 Plan preparer: Bohler Engineering [dhines @bohlereng.com] Owner or rep.: PANTOPS OFFICE BUILDING LLC Plan received date: 05 February 2014 Date of comments: 26 February 2014 Reviewer: Max Greene The Final Site Plan (SDP201400010) submitted 05 February 2014 has received Engineering Review and do not appear to meet Albemarle County minimum checklist items for approval. The following list of deficiencies will be adequately addressed prior to final approval of the site plan: A) Road and drainage plans (SDP201400010) 1) Retaining wall design will be site specific. Generic wall designs are no longer accepted. a) Geo -grid may extend 20' or more into site and may be under the load bearing portion of the buildings soil foundation. b) Wall construction inspections will be required and as -built records may be requested prior to final Certificate of Occupancy. C) Retaining wall appears to be only about 18" wide from face of footing to back on top of wall as scaled on plan view. Is this the actual dimension once the wall is installed? Please be sure retaining wall and guard rail will not cause the pavement width to narrow during construction. 2) Please show pavement stripping with dimensions for access isles on the site plan. Angled parking requires 16' minimum travel isle and drive thru lane will be 12' minimum width. Both do not appear adequately addressed at this time. 3) Please add a note to the planting plan "Sight easements will be maintained at all times. Limbing of trees and shrubs may be required for vehicular safety." 4) Albemarle County has a 3' minimum width for parking islands. One parking island is labeled 2.8' and needs to be widened to the minimum 3' width. The 3' width is the minimum for car door swing and safe entry into vehicle. 5) Please show safety slabs for manhole structures over 12' in depth. 6) Please show inlet shaping for the bottoms of manhole structures to prevent erosive forces from corroding structure and to prevent the pounding of waters that may harbor mosquitoes. 7) Please show benchmark location, elevation and datum for topography. An existing utility or other known position will suffice. Engineering Review Comments Page 2 of 2 B) Stormwater Management and Mitigation Plan 1) Stormwater Management appears to have been adequately addressed with the DMV Final Site plan #1999 -127 and is currently being converted to SWM facility. C) Erosion Control Plan 1) Erosion and Sediment Control Plan with application and fee will be submitted for review and approval. Existing early grading permit for stock pile area will be replaced with new WPO plan for Final Site Plan. http:// www .albemarle.org/upload/images/ forms_ center /departments /Community Developme nt/forms/En ineeringandWPOForms /PlanReview- _Application Stormwater _Management -BMP Plan.pdf Once these comments have been addressed, please submit 2 copies of the revised plans, calculations, and narratives to Current Development Engineering along with the required review fee and transmittal form. Current Development Engineering is available from 2:30 -4 PM on Thursdays to discuss these review comments. Please contact Max Greene at 434 - 296 -5832 ext. 3283 or email mjzreene @albemarle.org to schedule an appointment. File: CDDEl_sdp_MRG_Rolldn Road Retail Center.doc