HomeMy WebLinkAboutSDP201400006 Review Comments Minor Amendment 2014-02-21�'IRGIN�Q'
County of Albemarle
Department of Community Development
401 McIntire Road,
Charlottesville, VA, 22902
Phone 434 - 296 -5832 Fax 434- 972 -4126
Memorandum
To: Steve Edwards (swedwards8168CEDgmail.com)
From: Sarah Baldwin, Senior Planner
Division: Planning
Date: February 20, 2014
Subject: SDP 201400060 Willow Glen -Minor Site Plan Amendment & Variation Request Dated 12/16/13
The County of Albemarle Planning Division will recommend approval of the plan referenced above once the
following comments have been satisfactorily addressed (The following comments are those that have been
identified at this time. Additional comments or conditions may be added or eliminated based on further review.):
[Each comment is preceded by the applicable reference, which is to the Subdivision /Zoning Ordinances unless
otherwise specified.]
1. [8.5.5.3] Removing interparcel connections are not recommended and may not qualify as variation without
providing alternative locations. Please provide more information on why the future interparcel connections
are being removed.
2. [8.5.5.3] Please provide further clarification why additional condominiums are being removed. What certain
market conditions exist?
3. [8.5.5.3] Please provide further clarification regarding the removal of the tot lot. Again, what are the market
conditions that exist?
4. [Comment] Sheet 5 does not show the townhome units that are proposed in the variation.
5. [Engineer Comments] Are attached.
6. [VDOT Comments] Are attached.
7. [Fire Rescue Comments] Are attached.
Please contact Sarah Baldwin in the Planning Division by using sbaldwin(r)albemarle.c, or 434- 296 -5832 ext.
.3313 for further information. -- -- -- -
Review Comments
Project Name: Willow Glen Minor Amendment
Date Completed: Wednesday, February 05, 2014
Reviewer: Glenn Brooks
Department/Division /Agency: Engineering
Reviews
1. An amendment to the erosion and sediment control plans will be needed if they are still active.
2. Removing the interparcel connections is not recommended.
Review Status: See Recommendations
COMMONWEALTH of VIRCjINIA
DEPARTMENT OF TRANSPORTATION
1601 orange Road
Culpeper, Wgnia 22701
Charles A. Kilpatrick, P.E.
Commissioner
February 7, 2014
Ms. Sarah Baldwin
Senior Planner
Albemarle County
Department of Community Development
401 McIntire Road
Charlottesville, VA 22902
Re: SDP - 2014 -60 Willow Glen
Dear Ms. Baldwin:
We have reviewed the Minor Site Plan Amendment for Willow Glen, Phase 2 dated January 21,
2014 as submitted by Steve Edwards and offer the following comments:
1. Good access management practice minimizes the number of entrances on any given
roadway. We would recommend that the single family lots along Heathrow Glen Circle
continue to use shared entrances. Where possible, it would be good practice for the
townhouse units to use shared entrances as well.
2. The entrance shown to Lot 40 is very close to the intersection of Heathrow Glen Circle
and Shannon Glen Court. It may prove difficult for a vehicle traveling from Shannon
Glen Court to this parcel to make this turning movement without crossing into the
opposing lane.
3. Storm sewer should cross the public roads perpendicularly. An additional structure may
be needed near the property line between Lots 741 and 74J to allow the storm sewer to
cross Prestwick Glen Drive perpendicularly.
4. It is unclear to us whether the road plans and /or site plan for this development have
previously been approved. Please advise to the status of prior approvals.
If you need additional infonnation concerning this project, please feel free to contact me.
Sincerely,
t
Troy Austin, P.E..
Area Land Use Engineer
Culpeper District
WE KEEP VIRGINIA MOVING
Review Comments
Project Name: Willow Glen Minor Amendment
Date Completed: Imonday, February 10, 2014
Reviewer: Robbie Gilmer
Department/Division /Agency: Fire Rescue
Reviews
Based on plans dated 1/21/14
1: Radii at the north end of Hartsfield Court shall not be less then 25 ft. This will allow for.Fire Access to building A
Lot 1 and Building B lot 2.
2. Fire Hydrant spacing shall be every 500 ft per travelway.
3. Fire Flow test required prior to final submittal.