HomeMy WebLinkAboutSDP201400019 Review Comments Major Amendment, Final Site Plan 2014-04-07�pF A
vt�r�1Q
COUNTY OF ALBEMARLE
Department of Community Development
401 McIntire Road, Room 227
Charlottesville, Virginia 22902 -4596
Phone (434) 296 -5832 Fax (434) 972 -4126
Project: Surface Parking Expansion - Initial
Plan preparer: Delta Airport Consultants, Inc. [804- 275 -8301]
Owner or rep.: Charlottesville - Albemarle Airport Authority
Plan received date: 25 Feb 2014
Date of comments: 7 Apr 2014
Reviewer: Michelle Roberge
Engineering has completed the review of application SDP201400019.
A. Site Development Plan (SDP201400019)
1) On sheet 8, the existing parking lot should not be hatched solid. Only show in bold the areas that
are proposed.
2) What is the width of the entrance to the existing parking lot? The minimum requirement is 12'
wide for one way.
3) Place a yield sign at the exit lane intersecting Bowen Loop.
4) Remove parking spaces next to the travelway and revise to island curbs. Per our policy, a parking
space is separated 18' at a minimum to entrance.
Jr
1
it^ i 'I.�'Jvl•17 ! .3.07 BASE�LNE 'n
3� ('G 2
5) Provide all existing easements: sanitary, drainage and etc with deed book and page number.
6) The site plan should not contain erosion control plans or stormwater management plans. Also
Engineering Review Comments
Page 2 of 2
remove details pertaining to these plans. These will be reviewed with the WPO application. The
title of the WPO plans should include ` E &S and Stormwater Management."
7) Critical slopes being disturbed are "managed slopes." Address 30.7.5 (b) (2), [1]ocation of toe of
the fill slope.
"The toe of any fill slope shall not be located within 10 feet horizontally of the top of an existing
or proposed cut slope."
8) Site has to be field verified within the last year. Please verify. Provide date and name of surveyor.
9) Provide low maintenance ground cover (not grass) for 2:1 slopes and specify on plan.
10) All proposed permanent easements shall be dimensioned and labeled: drainage, sight, swm facility
and access to SWM.
11) Remove all trees on drainage structures. Provide 3' horizontal clearance.
12) VDOT approval shall be obtained for entrance intersecting Dickerson Road.
13) Provide, at a minimum, a 25' radius at entrance intersecting Dickerson Road.
14) Entrances shall not exceed 4% grade for a distance of 40' from intersected road.
15) Provide existing contour labels.
Sincerely,
r"de-
Michelle Roberge