HomeMy WebLinkAboutSDP201400004 Review Comments Initial Site Plan 2014-02-20�pF A
vt�r�1Q
COUNTY OF ALBEMARLE
Department of Community Development
401 McIntire Road, Room 227
Charlottesville, Virginia 22902 -4596
Phone (434) 296 -5832 Fax (434) 972 -4126
Project:
Plan preparer:
Owner or rep.:
Plan received date:
Date of comments:
Reviewer:
Out of Bounds — Initial
Shimp Engineering, P.C.
Vito Cetta
22 Jan 2014
20 Feb 2014
Michelle Roberge
RE: Site Development Plan (SDP201400004)
Out of Bounds — Initial (SDP201400004) has been reviewed. Please address the following comments:
1. Show sight distances at intersections.
2. The minimum turning radius at street intersections on subdivision streets shall not be less than 25
feet. Please revise.
3. Revise the sag curve in road `B" to meet the 155' minimum stopping sight distance.
4. For T -type turnarounds, please show a mountable curb, a VDOT CG -3 or a VDOT rolltop curb.
Please spec the sidewalk in that area to 7" for vehicles.
5. Revise the sidewalk layout near the T -Type turnaround on Bennington Rd to match the layout in
Road `B."
6. Replace Str19 -1 and 20 -1 to domed grate inlets to provide relief if ST -18 is clogged.
7. Roof drains for lots 39 -51 are not designed to handle larger storms. Please show runoff to drain
from residential units to the road to be captured by DIs.
8. Show drainage improvements near Smithfield Road for downstream improvements. This is part of
proffer #5 A.
9. Are there any future connections for the proposed roads? A grading easement to the property line
may be necessary for future connections. Also, the lot line for lot 44 may need to be adjusted.
10. Where is the electric line layout? Please verify that the electric line will not be in any conflict with
the proposed underground basins and other utilities.
These comments can be addressed at final site plan.
1. Increase the easement around the underground detention basin for an equipment landing. Use the
link below for the trench width.
http:// www .albemarle.org/upload/images/ forms _center /departments /community development/for
ms /design standards _manual /Albemarle Cogp& D_ esign Standards_ Manual_220ct2012.pdf
2. Show the access road easement for the underground detention basins.
3. Label the CG type on the plan. Also, please provide the standard VDOT aprons for the driveways
(CG -9D).
4. Please provide the width of all access easements. It does not appear that all sidewalks that may
require an access easement are shown on the plan. Please clarify. For example, the lots 45 -51 and
south of lot 6 are showing sidewalks, but no easements.
5. Label or note dimensions of parking stalls. It appears the parking on Georgetown Road Extension
does not match the pavement section on sheet C 11.
6. Show the detail of the retaining wall.
7. Provide the private road easement in between lots 45 to 51.
Engineering Review Comments
Page 2 of 2
8. Provide bumper blocks or increase the sidewalk width to 6' in front of lots 48 -51.
9. It is difficult to read the pavement sections. For road plans, please spec and dimension pavement
sections.
10. Show the proposed fence on sheet C7 and C8. Also, a portion of the existing fence on sheet C -5 is
missing. Please show.
11. Update the scale on title block of sheets with road profiles. It is not matching what is shown on
plan.
Sincerely,
Michelle Roberge