HomeMy WebLinkAboutSDP201400027 Review Comments Minor Amendment 2014-04-17Albemarle County
Service Authority
TO: Rachel Falkenstein
FROM: Alexander J. Morrison, E.I.T., Civil Engineer
DATE: April 16, 2014
RE: Site Plan Technical Review for: SDP201400027: Avemore LLC Phase III
The below checked items apply to this site.
✓ 1. This site plan is within the Authority's jurisdictional area for:
✓ A. Water and sewer
B. Water only
C. Water only to existing structure
D. Limited service
✓ 2. An 8 inch water line is located approximately on site distant.
3. Fire flow from, nearest public hydrant, located distant from this site plan, is
Gpm + at 20 psi residual.
✓ 4. An 8 inch sewer line is located approximately on site distant.
5. An Industrial Waste Ordinance survey form must be completed.
✓ 6. No improvements or obstructions shall be placed within existing or future
easements.
7. and plans are currently under review.
8. and plans have been received and approved.
9. No plans are required.
10. Final and plans are required for our review and approval prior to
granting tentative approval.
11. Final site plan may /may not be signed.
12. RWSA approval for water and /or sewer connections.
13. City of Charlottesville approval for sewer.
✓ Comments:
Dedication of Phase IIIA required prior to the ACSA granting approval. ACSA staff is
reviewing dedication documents and will submit it to the Executive Director for
acceptance. If any additional information is required the ACSA will contact the applicant.
Show existing water main sizes.
Show existing sewer main sizes.
Show proposed sewer lateral connections from the building to the existing stub -out.
Call out fittings, line sizes and construction notes for the new water meter arrangement.
Re -align the new water meter arrangement so the corporation stops are under grass
instead of the sidewalk.
168 Spotnap Road • Charlottesville • VA 22911 • Tel (434) 977 -4511 • Fax (434) 979 -0698
www.serviceauthority.org
Albemarle County
Service Authority
Serving ♦ conserving
Confirm that there will be no uses in the building that would require a grease interceptor
on the private side of the sewer connection.
Call out back flow preventers for each water service connection.
Call out a new ACSA water easement for the water main serving the proposed line of
meters.
168 Spotnap Road • Charlottesville • VA 22911 • Tel (434) 977 -4511 • Fax (434) 979 -0698
www.serviceauthority.org