HomeMy WebLinkAboutSDP201300046 Review Comments Final Site Plan and Comps. 2014-04-01.may i C �1 q� � • n fly COMMONWEALTH of VIRGINIA DEPARTMENT OF TRANSPORTATION 1601 Orange Road Culpeper, Virg -n,a 22701 Charles A. Kilpatrick, P.E. Commissioner March 31, 2014 Mr. Brent Nelson County of Albemarle Department of Community Development 401 McIntire Road Charlottesville, VA 22902 Re: SDP2013 -00046 Gillenwater Property Tier II Personal Wireless Service Facility (AT &T Wireless 648 Dry Bridge Road) Dear Mr. Nelson: We have reviewed the subject facility in the field and reviewed the plans identified as AT &T site number CV404A as submitted by BC Architects Engineers and dated 1/14/.14. Per the attached letter from the design engineer, should there be a structural failure, the tower collapse would be no further than 56' from the center of the structure, which would approximately 10 to 15 feet from the edge of pavement of Route 708. Under these conditions, the fall zone of the tower would not impact Route 708 and VDOT has no objections to the proposed facility as designed. The applicant will need to obtain a Land Use Permit from this office for the proposed entrance and any necessary work to be performed on the State Right -of -Way. If you need additional information concerning this project, please feel free to contact me. Sincerely, Troy ustin, P.E. Area Land Use Engineer Culpeper District WE KEEP VIRGINIA MOVING BC a r c h i r e c t s e n g i n e e r s March 28, 2014 Mr. Preston Lloyd Williams Mullen RE: CV404A 6448 Dry Bridge Road, Charlottesville, VA 22903 119.4' Monopole 1- Carrier Design Tower Specification Mr. Lloyd, The 119.4' tower for the above listed site will comply with the following design specifications and criteria: 1. EIA /TIA -222G. The tower and foundation will meet the requirements outlined in the 2012 IBC. 2. Wind loading will be designed based on a minimum 90 -mph basic wind speed and a minimum 1/2" of radial ice to design the steel structure. Designer shall contact all local governing officials to determine if minimum standards apply. 3. Foundations will be designed in accordance with the latest version of ACI and actual geotechnical values based on site data. Normal soils assumption will not be used. 4. Tower and foundation design calculations will be submitted to engineer for final approval. 5. The tower and foundation shall be designed, manufactured, and constructed to have the capacity to accommodate 1- carrier's full antenna arrays. 6. In the event of structural failure, the tower will be designed to collapse no farther than 56' from the center of the structure. Please contact us if you have any questions or concerns. Sincerely, C Christopher D. Morin, P.E. Principal of BC Architects Engineers, PLC "' O' CHRISTOPHER D. v MORIN N0. 82984 �o 43 1 sslOATAT. BC Architects Engineers, PLC 5661 Columbia Pike, Suite 200, Falls Church, VA 22041 -2868 Telephone (703) 671 -6000 Fax (703) 671 -6300