Loading...
HomeMy WebLinkAboutARB201400066 Review Comments Miscellaneous Submittal 2014-05-20Brent Nelson From: Brent Nelson Sent: Tuesday, May 20, 2014 9:56 AM To: 'gina.p @atlassignindustries.us' Subject: ARB201400066, One Main Financial Sign, 1807 Seminole Trail, Staff Comments Attachments: 1807 Seminole Trail.pdf Importance: High Gina - I am sending this email as a follow up to our phone conversation yesterday. I am the planner reviewing your Architectural Review Board (ARB) sign application for compliance with approved comprehensive sign criteria (CSC) for this location (attached) and the ARB General Sign Guidelines. The following issues have been identified that will need to be adequately addressed for my administrative approval. Channel Letter Text Color: • Approved CSC for this location require the use of Blue: Pantone 294 for channel letter faces, trim caps & returns. Verify that the proposed 3M 3635 -8549 Blue perforated vinyl color is the same color as Blue: PMS 294. If it is, note it on the sign drawing. If it is not, revise to a vinyl color that does match Blue: Pantone 294. • Approved CSC for this location require the use of Blue: Pantone 294 for the channel letter text trim caps and returns. Revise the sign drawing to show the use of Blue: Pantone 294 for the channel letter text trim caps and returns. • Revise the sign drawing to include a note indicating the blue channel letter text shall illuminate as white. This can be approved since CSC allow for white channel letters as well. Channel Letter Graphic Color: • Revise the sign drawing to include the Pantone number for each of the graphic faces. The trim cap and return colors must match the face color. Raceway Color: • Approved CSC for this location require that the raceway color match Pantone 423. The proposed SW256 paint color does not appear to match . Revise the sign drawing to indicate the use of a paint color to match Pantone 423. LED Illumination: • The ARB requires a limit to the intensity of LED illumination. Revise the sign drawing to include the following note: The level of illumination provided by the LED lights will not exceed the illumination produced by a single stroke of 30 milliamp (ma) neon. Please contact me should you have any questions or concerns. Emailing the revised drawing back to me is preferred. Brent Brent W. Nelson Planner Planning Services Department of Community Development County of Albemarle 401 McIntire Rd. Charlottesville, VA 22902 434 - 296 -5832 ext. 3438