HomeMy WebLinkAboutSDP201400051 Review Comments Final Site Plan and Comps. 2014-08-15Q �'I�l3lP COUNTY OF ALBEMARLE Department of Community Development Planning Services 401 McIntire Road, North Wing Charlottesville, Virginia 229024596 Phone (434) 296 -5832 Fax (434) 972 -4126 August 15, 2014 Kent O'Donohue Balzer and Associates, Inc. 1561 Commerce Road Suite 401 Verona, VA 24482 RE: SDP - 2014 -00051 Goodwill Final Site Plan Dear Sir, The following divisions of the Department of Community Development and other agencies, as applicable, have reviewed the above -noted application. Preliminary comments are listed below: Albemarle County Division of Planning (Planner) • Brent Nelson, Planner, bnelsongalbemarle.org • Albemarle County Code [Section 30.7.5, a] Steep Slopes Overlay District, Design Standards: See County Engineering comments below regarding proposed wall with 7' height not meeting design standards. Albemarle County Division of Engineering: • Max Greene, Engineer Technician, mereene .albemarle.org • The retaining wall is in a critical slope area per County GIS designated as "Managed Slope ". Managed Slope areas are not to have retaining walls with exposed faces taller than 6 feet. To keep the plan in accordance with the Albemarle County Code, please adjust the height of the wall or break the area up into multiple walls per [18- 30.7.5.a] • Please submit a Wall Construction plan for this site. The Wall design will be the same as the design used for the wall building permit. + Waiting for WPO approvals (WP0201400041) • Waiting for Stormwater Credit confirmation from the State. Forwarded all a -mails from consultant to County Engineer for clarification on VSMP requirements. Albemarle County Division of Inspections — No Objection • Jay Schlothauer, Building Official, jschloth&a albemarle.org Albemarle County Department of Fire Rescue: + Robbie Gilmer, Assistant Fire Marshall, 434 - 296 -5833, reilmer e,albemarle.org Fire Flow test required prior to final approval. • Fire flow requirements shall be 2250 gpm @20 psi without an approved sprinkler system. • Fire flow requirements shall be 1500 gpm @20 psi with an approved sprinkler system. Virginia Department of Transportation (VDOT) — Comments have not been received • Troy Austin, Area Land Use Engineer, Nathran.Austin(a vdot.virginia.gov Albemarle County Architectural Review Board — No Objection • Margaret Maliszewski, Design Planner, mmaliszewski@albemarle.org Albemarle County Service Authority (ACSA) Alex Morrison, Civil Engineer, amorrison2serviceauthority.org • See attached staff comments • See attached fire flow report A note should be added which calls out a backflow device on the domestic service (private side). For those reviewers with outstanding comments, please work directly with them from this point on to satisfy those comments and have them notify me when their tentative approval has been obtained. Staff has provided references to provisions of Chapter 18 of the Code of the County of Albemarle. The Code is kept up to date by the County Attorney's office. The Code may found on the County Attorney's website which may be found under "Departments and Services" at Albemarle.org. In accord with the provisions of Section 32.4.3.5 of Chapter 18 of the Code if the developer fails to submit a revised final site plan to address all of the requirements within six (6) months after the date of this letter the application shall be deemed to have been voluntarily withdrawn by the developer. Please contact me at your earliest convenience if you have questions or require additional information. Sincer Brent Nelson, Planner County of Albemarle Department of Community Development Planning Services 401 McIntire Road Charlottesville, VA 22902 -4596 Email: bnelson&albemarle.org Phone: (434) 296 -5832 Ext 3438 Fax: (434) 972-4126 cc: Bob Pingry (via email) Service Auth♦rity TO: Brent Nelson FROM: Alexander J. Morrison, Civil Engineer DATE: August 6, 2014 RE: Site Plan Technical Review for: SDP2014051: Goodwill - Mill Creek Drive The below checked items apply to this site. ✓ 1. This site plan is within the Authority's jurisdictional area for: ✓ A. Water and sewer B. Water only C. Water only to existing structure D. Limited service ✓ 2. An 8 inch water line is located approximately on site distant. 3. Fire flow from, nearest public hydrant, located distant from this site plan, is Gpm + at 20 psi residual. ✓ 4. An 8 inch sewer line is located approximately on site distant. 5. An Industrial Waste Ordinance survey form must be completed. ✓ 6. No improvements or obstructions shall be placed within existing or future easements. 7. and plans are currently under review. 8. and plans have been received and approved. 9. No plans are required. ✓ 10. Final water construction plans may be required (see comments below). 11. Final site plan may /may not be signed. 12. RWSA approval for water and /or sewer connections. 13. City of Charlottesville approval for sewer. ✓ Comments: • Advise if a sprinkler system will be installed in this building. Based on conversations with the Department of Fire Rescue, the fire flow requirement for your building (based on square footage, building material and no sprinkler) is 2,250 GPM for 2 hours. The ACSA is scheduling a fire flow test to confirm that the AWWAQ20 of 2,250 GPM for the fire hydrant coverage will not be possible. If a sprinkler system is installed the required fire flow would be 1,500 GPM for 2 hours. All fire flow requirements outlined in my comments are for informational purposes only and are required to be confirmed by Robbie Gilmer with the Department of Fire Rescue. • If a sprinkler system will be installed, the fire line should be extended from the existing gate valve on the stub -out located to the east of the proposed building. The ACSA ownership will end at the existing gate valve. 168 Spotnap Road • Charlottesville • VA 22911 • Tel (434) 977 -4511 • Fax (434) 979 -0698 www.serviceauthority.org Service Authdority • The water meter tap should be shown on the existing 8" water main which is aligned parallel to the east side of the proposed building. • If no sprinkler system will be installed, 3 sets of water construction drawings are required for ACSA construction review and approval to abandon the existing stub -out at the tee. 168 Spotnap Road • Charlottesville • VA 22911 • Tel (434) 977 -4511 • Fax (434) 979 -0698 www.serviceauthority.org Service Autfill4rity Hydrant Flow tfA SW"j hw ]t nn j nrsvrse .as VA 7.7.911 OM) n�rrit Test Report Location Mill Creek Dr Date and Time of Test 8/7/2014 10:00:00 AM Minutes of Flow 2 Pipe Size (in) 6 Pressure Hydrant 11611 Static Pressure (psi) 28 Residual Pressure (psi) 23 Flow Hydrant #1 11612 Pitot Pressure #1 (psi) Now Hydrant #2 Pitot Pressure #2 (psi) Flow Hydrant #3 Pitot Pressure #3 (psi) Total Estimated Flow (gpm) 655 Estimated Consumption (gal) 1,310 AW WA Q20 Calculation (gpm 0 (Value of zero indicates insufficient pressure drop for calculation) Comments Hydrants open all the way Date of Report 8/7/2014' 22 Test Flow #1 (gpm) 655 Test Flow #2 (gpm) 0 Test Flow #3 (gpm) 0 For method of calculating pltot flow with a diff user: see eq. 13, Walski and Lutes article 1990 Journal Management and Operations AW WA (All tests conducted using 2.5 discharge outlet unless otherIe specified) { Signature of Tester: 011AA 4-2 I 1 i r i• i I.' 4x , >.0 o ,O mom Nog, Vol AM Lo n M O � W • a� m E �s L N y~ C N 4 :E 0 m m b C L � p O C �E LM E `mac —mo �pna,opooQ C= C N Y3 �� •J W C E'Vi w�maoy��Eo °a = P : o c a E > c g m N c o a a o f a m.Lm. EEi ^o o Q ©,« L� C a� v Z' m lL =moL ii NU1mE c Nacr�.Qmt �•�? �o o p m a c —mE m N /Cb i L •.8 2 CD M m '•8 C9 S hp�b n .E Hi�8s 41, 4Qj cb o ,O Lo n M O Brent Nelson From: Alex Morrison [amorrison @serviceauthority.org] Sent: Wednesday, August 06, 2014 2:39 PM To: Brent Nelson Subject: SDP2014051- Goodwill - Mill Creek Drive Attachments: SDP2014051- Goodwill - Mill Creek Drive.pdf COUNTY OF ALBEMARLE Department of Community Development 401 McIntire Road, Room 227 Charlottesville, Virginia 22902 -4596 Dear Brent : The Albemarle County Service Authority (ACSA) has received and reviewed the plan /document /project described above. Attached is the ACSA comment sheet with any relevant comments and concerns we may have regarding the plan /document /project. Please feel free to contact me at the number below with any comments or questions you may have about the attached ACSA comment sheet. Thank you. Alexander J. Morrison, EIT Civil Engineer Albemarle County Service Authority 168 Spotnap Road Charlottesville, Virginia 22911 (0) 434 - 977 -4511 Ext. 116 (F) 434 - 979 -0698 Like the ACSA on Facebook at www.facebook.com /acsaconnect y F � Service Auth6rity TO: Brent Nelson FROM: Alexander J. Morrison, Civil Engineer DATE: August 6, 2014 RE: Site Plan Technical Review for: SDP2014051: Goodwill - Mill Creek Drive The below checked items apply to this site. ✓ 1. This site plan is within the Authority's jurisdictional area for: ✓ A. Water and sewer B. Water only C. Water only to existing structure D. Limited service ✓ 2. An 8 inch water line is located approximately on site distant. 3. Fire flow from, nearest public hydrant, located distant from this site plan, is Gpm + at 20 psi residual. ✓ 4. An 8 inch sewer line is located approximately on site distant. 5. An Industrial Waste Ordinance survey form must be completed. ✓ 6. No improvements or obstructions shall be placed within existing or future easements. 7. and plans are currently under review. 8. and plans have been received and approved. 9. No plans are required. ✓ 10. Final water construction plans may be required (see comments below). 11. Final site plan may /may not be signed. 12. RWSA approval for water and /or sewer connections. 13. City of Charlottesville approval for sewer. ✓ Comments: • Advise if a sprinkler system will be installed in this building. Based on conversations with the Department of Fire Rescue, the fire flow requirement for your building (based on square footage, building material and no sprinkler) is 2,250 GPM for 2 hours. The ACSA is scheduling a fire flow test to confirm that the AWWAQ20 of 2,250 GPM for the fire hydrant coverage will not be possible. If a sprinkler system is installed the required fire flow would be 1,500 GPM for 2 hours. All fire flow requirements outlined in my comments are for informational purposes only and are required to be confirmed by Robbie Gilmer with the Department of Fire Rescue. • If a sprinkler system will be installed, the fire line should be extended from the existing gate valve on the stub -out located to the east of the proposed building. The ACSA ownership will end at the existing gate valve. 168 Spotnap Road • Charlottesville • VA 22911 • Tel (434) 977 -4511 • Fax (434) 979 -0698 www.serviceauthority.org Service Authority _.n.. q• ".: "elf *. • The water meter tap should be shown on the existing 8" water main which is aligned parallel to the east side of the proposed building. • If no sprinkler system will be installed, 3 sets of water construction drawings are required for ACSA construction review and approval to abandon the existing stub -out at the tee. 168 Spotnap Road • Charlottesville • VA 22911 • Tel (434) 9774511 • Fax (434) 979 -0698 www.serviceauthority.org Brent Nelson From: Alex Morrison [amorrison @serviceauthority.org] Sent: Wednesday, August 06, 2014 2:41 PM To: Brent Nelson Subject: RE: SDP2014051- Goodwill - Mill Creek Drive Brent, I would like to add 1 more requirement. A note should be added which calls out a backflow device on the domestic service (private side). Alexander J. Morrison, EIT Civil Engineer Albemarle County Service Authority 168 Spotnap Road Charlottesville, Virginia 22911 (0) 434 - 977 -4511 Ext. 116 (F) 434 - 979 -0698 Like the ACSA on Facebook at www.facebook.com /acsaconnect From: Alex Morrison [ mailto: amorrison Caaserviceauthority.orci] Sent: Wednesday, August 06, 2014 2:39 PM To: bnelson(aalbemarle.org Subject: SDP2014051- Goodwill - Mill Creek Drive COUNTY OF ALBEMARLE Department of Community Development 401 McIntire Road, Room 227 Charlottesville, Virginia 22902 -4596 Dear Brent : The Albemarle County Service Authority (ACSA) has received and reviewed the plan /document /project described above. Attached is the ACSA comment sheet with any relevant comments and concerns we may have regarding the plan /document /project. Please feel free to contact me at the number below with any comments or questions you may have about the attached ACSA comment sheet. Thank you. Alexander J. Morrison, EIT Civil Engineer Albemarle County Service Authority 168 Spotnap Road Charlottesville, Virginia 22911 (0) 434 - 977 -4511 Ext. 116 (F) 434 - 979 -0698 Like the ACSA on Facebook at www.facebook.com /acsaconnect Brent Nelson From: Alex Morrison [ amorrison @serviceauthority.org] Sent: Thursday, August 07, 2014 3:47 PM To: Brent Nelson Subject: SDP2014051: Goodwill Final Site Plan Attachments: 20140807153946084. pdf Brent, The ACSA has completed a fire flow test for the water main located in the vicinity of the proposed Goodwill. Please forward the attached fire flow report to the applicant for use in the design. Thank you. Alexander J. Morrison, EIT Civil Engineer Albemarle County Service Authority 168 Spotnap Road Charlottesville, Virginia 22911 (0) 434 - 977 -4511 Ext. 116 (F) 434 - 979 -0698 Like the ACSA on Facebook at www.facebook.com /acsaconnect 5erviceAuthii►rity Hydrant Flow ==' Test Report if$5lX>♦l ran f{(HKI C:fLStfpttF"�YA4 ]17;1111 OAI14iidhl Location Mill Creek Dr Date and Time of Test 8/7/201410:00:00 AM Minutes of Flow 2 Pipe Size (in) 6 Pressure Hydrant 11611 Static Pressure (psi) 28 Residual Pressure (psi) 23 Flow Hydrant #1 11612 Pitot Pressure #1 (psi) Flow Hydrant #2 Pitot Pressure #2 (psi) Flow Hydrant #3 Pitot Pressure #3 (psi) Total Estimated Flow (gpm) 655 Estimated Consumption (gal) 1,310 AW WA Q20 Calculation (gpm 0 (Value of zero Indicates insufficient pressure drop for calculation) Comments Hydrants open all the way Date of Report 8/7/2014 22 Test Flow #1 (gpm) 655 Test Flow #2 (gpm) 0 Test Flow #3 (gpm) 0 For method of calculating pltot flow with a diffuser: see eq. 13, Walskland Lutes article 1990 Journal Management and Operations AW WA (All tests conducted using 2.5 discharge outlet unless otherwi3e specified) Signature of Tester: Ap Q- 0 m m LL U) LO Y r m 7 a Z c o Q O a¢ 1 M :• L j�Swi J� T VI j� 4 uM'