HomeMy WebLinkAboutSUB201400111 Review Comments Preliminary Plat 2014-07-24Albemarle County
Service Authority
TO: Rachel Falkenstein
FROM: Alexander J. Morrison, E.I.T., Civil Engineer
DATE: July 23, 2014
RE: Site Plan Technical Review for: SUB201400111: Wintergreen Farms - Preliminary
Subdivision Plat
The below checked items apply to this site.
✓ 1. This site plan is within the Authority's jurisdictional area for:
✓
A. Water and sewer
B. Water only
C. Water only to existing structure
D. Limited service
✓ 2.
A 20 (RWSA) inch water line is located approximately 0' distant.
3.
Fire flow from, nearest public hydrant, located distant from this site plan, is
Gpm + at 20 psi residual.
✓ 4.
An 8 inch sewer line is located approximately 25' distant.
5.
An Industrial Waste Ordinance survey form must be completed.
✓ 6.
No improvements or obstructions shall be placed within existing or future
easements.
7.
and plans are currently under review.
8.
and plans have been received and approved.
9.
No plans are required.
✓ 10.
Final water and sewer plans required before granting final site plan and
construction approval.
11.
Final site plan may /may not be signed.
12.
RWSA approval for water and /or sewer connections.
13.
City of Charlottesville approval for sewer.
✓
Comments:
Final water and sewer plans required for ACSA construction approval.
During the utility design stage the ACSA will investigate a sewer connection with
Redfields to eliminate the Redfields wastewater pump station.
During the utility design stage the ACSA will review the 2 pressure bands that will be
present within the subdivision with the proposed watermain connections (Urban Ring and
Mosby Mountain pressure bands).
Proposed water main connections to RWSA infrastructure require RWSA approval. The
ACSA will request initial approval when the initial site plan is submitted for review.
168 Spotnap Road • Charlottesville • VA 22911 • Tel (434) 977 -4511 • Fax (434) 979 -0698
www.serviceauthority.org
Albemarle County
Service Authority
The Albemarle County Service Authority (ACSA) has no technical comments on the SUB
being reviewed. Engineering comments are usually reserved for the site plan review stage.
Subdivision plats should correctly show ownership of properties and existing easements. Recordation
of new easements should occur before dedication to and acceptance by the ACSA.
The ACSA can review the proposed subdivision plat and determine if it is included in the
jurisdictional area for water and /or sewer service. Water and /or sewer connections to the ACSA
system are allotted on a first come, first served basis at the time connection fees are paid. The ACSA
does not reserve capacity in its system for a specific project.
168 Spotnap Road • Charlottesville • VA 22911 • Tel (434) 977 -4511 • Fax (434) 979 -0698
www.serviceauthority.org