Loading...
HomeMy WebLinkAboutSUB201400136 Review Comments Preliminary Plat 2014-09-18• C-TQ�. COUNTY OF ALBEMARLE Department of Community Development 401 McIntire Road, Room 227 Charlottesville, Virginia 22902 -4596 Phone (434) 296 -5832 Fax (434) 972 -4126 Project: Cascadia — Initial Site Plan & Preliminary Plat Plan preparer: Dominion Engineering [434- 979 -8121] Owner or rep.: Cascadia Development, LLC Plan received date: 13 May 2014 Date of comments: 18 Sep 2014 Reviewer: Michelle Roberge Engineering has completed the review of application SDP201400057 & SUB201400136. A. Initial Site Plan (SDP201400057) 1) Show matchlines on sheets. 2) There are items from blocks 4 -7 shown as existing on this plan, which means that this application will be approvable once the subdivision, site plan and wpo plan from blocks 4- 7 are approved. Please clarify if this is how you would like to proceed. Also, there is a new grading plan for lots along the proposed Delphi Lane extension and commercial bldg area. This area has changed since the approved WP02013 -32. Please address how you would like to proceed with coordination of that plan. For example, a sediment trap should be placed south of the proposed Cascadia Drive. What are revisions to the erosion control measures as the temporary conveyance channel is removed and Dephi Lane is constructed? 3) In conjunction with comment 2, the SWM Pond #2 is shown as existing. Under the new VSMP regulations, as- builts shall be provided for existing SWM facilities. Since the facility is not yet built, please clarify coordination of these plans. 4) There should be no disturbance within the SWM Pond #2 easement. It appears the layout of the commercial site shows disturbance within this easement. Please address. 5) The road plan shall be approved by VDOT. 6) Parking should be separated from entrances and street. Remove the parallel parking near the commercial bldg. One recommendation is to rotate the entire parking layout by 90 degrees and remove the choked entrance or flip the bldg and parking lot to change entrance location. 7) I do not recommend the street ending as shown near lot 22. I recommend a radius of 200' to avoid this stub out. Engineering Review Comments Page 2 of 2 8) Show and label the managed slopes. 9) All retaining walls on managed slopes should adhere to section 30.7.5[a] of Albemarle County Code. 10) Show design of retaining wall. 11) Revise the road layout for lots 106 -111 and remove turnarounds and stubouts. Show a 200' radius and connect the Knoll Lane to Delphi Lane. 12) Provide drainage computations. B) Preliminary Plat (SUB201400136) 1) An approved and bonded road plan for blocks 1 -3 will be required prior to the approval of this plat. 2) VSMP/WPO may need to be updated per comment 2 under the initial site plan comment. Sincerely, MQAT- Michelle Roberge