HomeMy WebLinkAboutSP201100014 Legacy Document 2012-06-28 (11)COUNTY OF ALBEMARLE
PLANNING STAFF REPORT SUMMARY
Project Name: ZMA 2011 - 00006, Albemarle
Staff: Claudette Grant
Health and Rehab Center and SP 2011 - 00014,
Albemarle Health and Rehab Center
Planning Commission Public Hearing:
Board of Supervisors Public Hearing:
October 18, 2011
To be Determined
Owner(s): Galaxie, LLC
Applicant: Albemarle Health Care Center, LLC with
Bruce Hedrick as applicant contact. Contact: Justin
Shimp with Shimp Engineering.
Acreage: 5.38 acres
Rezone from: R -1, residential zoning district to PD-
MC, Planned Development Mixed Commercial zoning
district. A special use permit is proposed under
Section 24.2.2(7) of zoning ordinance for hospitals,
nursing homes, convalescent homes uses.
TMP: TMP 09100000001200 (a portion of)
By -right use: Residential uses at a density of 1 unit
Location: 91 Galaxie Farm Lane (Attachment A)
per acre. (Attachment B)
Magisterial District: Scottsville
Proffers: No
Proposal: Rezone 5.38 acres from R -1 zoning
Requested # of Dwelling Units: None
district to PD -MC Planned Development Mixed
Commercial zoning district. A special use permit is
proposed under Section 24.2.2(7) of zoning
ordinance for hospitals, nursing homes,
convalescent homes uses. No dwellings proposed.
DA (Development Area): Neighborhood 4
Comprehensive Plan Designation: Transitional —
neighborhood -scale commercial uses, offices,
townhouses and apartments (6.01 -34 units /acre) and
Urban Density Residential — residential (6.01 -34
units /acre); supporting uses such as religious
institutions, schools, commercial, office, and service
uses. (Attachment C)
Character of Property: The property has a 2 story
Use of Surrounding Properties: The property
house located on it. There are gentle slopes on the
adjacent and to the north is primarily vacant and
property. A portion of the site is wooded.
zoned for residential use. The Monticello Fire /Rescue
Station is located to the north east of the subject
property. The property to the south is zoned
residential and is a portion of the subject parcel and
Cale Elementary school is located to the south and
west of the property. Mill Creek Drive is the proposed
access for this site. Monticello High School and a
shopping center are located nearby on Mill Creek Dr.
Factors Favorable:
Factors Unfavorable:
1. Development of the property as a nursing
1. The proposal for the site is so
home is consistent with the Comprehensive
overdeveloped that the design requires grading,
Plan designation.
and easements, on the adjacent properties for
2. This rezoning request provides a need and
retaining walls, access road, and stormwater
service for the elderly in a portion of the County
management.
that does not have a similar use.
2. No permission has been received
from adjacent property allowing permission for the
necessary grading /easements on the subject
property. Without permission this project will not
be able to be developed as proposed.
3. The applicant is requesting a waiver
to provide over 20 percent more parking on the
ZMA 2011 - 00006, Albemarle Health and Rehab Center, SP 2011 - 00014, Nursing Home
Planning Commission Public Hearing, October 18, 2011
Staff Report, Page 1
ZMA 2011 - 00006, Albemarle Health and Rehab Center, SP 2011 - 00014, Nursing Home
Planning Commission Public Hearing, October 18, 2011
Staff Report, Page 2
site than what is required by the Zoning
Ordinance.
4. Multiple waiver requests for buffer,
landscape and minimum yard requirements (along
with off -site stormwater management and grading
indicates the proposal overdevelops the site.
RECOMMENDATION:
Staff recommends denial of ZMA 2011 -00006 and SP 2011 - 00014, Albemarle Health and Rehab Center with
waivers, based on the factors noted in this report as unfavorable.
ZMA 2011 - 00006, Albemarle Health and Rehab Center, SP 2011 - 00014, Nursing Home
Planning Commission Public Hearing, October 18, 2011
Staff Report, Page 2
STAFF PERSON:
PLANNING COMMISSION:
BOARD OF SUPERVISORS:
Claudette Grant
October 18, 2011
To Be Determined
ZMA 2011 - 00006, Albemarle Health and Rehab Center
SP 2011 - 00014, Albemarle Health and Rehab Center
With waiver requests of Section 21.7(b) of Zoning Ordinance for Minimum Yard Requirements;
Section 21.7 (c) for Required Buffers; Section 32.7.9.8 (c) for Required Screening; and Section
4.12.4(a) for Exceeding the maximum parking by more than 20%
PETITION
PROJECT: ZMA 201100006 and SP201100014 Albemarle Health and Rehab Center
PROPOSAL: Rezone 5.38 acres from R -1 zoning district which allows residential uses at a density
of 1 unit per acre to PD -MC Planned Development Mixed Commercial zoning district which allows
large -scale commercial uses; residential by special use permit at a density of 15 units /acre and
special use permit under Section 24.2.2(7) of zoning ordinance for hospitals, nursing homes,
convalescent homes uses. No dwellings proposed.
ENTRANCE CORRIDOR: No
PROFFERS: No
COMPREHENSIVE PLAN: Transitional — neighborhood -scale commercial uses, offices,
townhouses and apartments (6.01 -34 units /acre) and Urban Density Residential — residential (6.01-
34 units /acre); supporting uses such as religious institutions, schools, commercial, office, and
service uses and located in Neighborhood 4 in the Development Area.
LOCATION: 91 Galaxie Farm Lane
TAX MAP /PARCEL: 09100000001200
MAGISTERIAL DISTRICT: Scottsville
CHARACTER OF THE AREA
The proposed access for the subject property is Mill Creek Drive, which is located to the north of
this property. The property has an existing two story house on it, but is otherwise vacant and
wooded with trees and shrubs. It is located in the Development Area and surrounded by a
significant amount of development. The Monticello Fire /Rescue Station is located to the north east
of the subject property. The residual parcel proposed to be subdivided from the subject property is
vacant and zoned for residential use. It is located to the south of the site. Cale Elementary school is
located to the west of the property. Monticello High School, Tandem Friends School and a shopping
center are also located nearby on Mill Creek Dr.
SPECIFICS OF THE PROPOSAL
The applicant proposes to rezone 5.38 acres, which is a portion of tax map parcel 091 -00 -00 -01200
from R -1, residential to PD -MC, Planned Development Mixed Commercial to allow a 120 -bed
nursing home facility. A special use permit is requested to allow the nursing home facility. The
project will be developed in two phases; Phase 1 will include 90 beds. The applicant proposes a
single story nursing home in an approximately 57,655 square foot building. Approximately 90 full
and part -time employees will be employed, providing nursing and rehabilitative care 24 hours per
day. (See Attachment D: Application Plan)
APPLICANT'S JUSTIFICATION FOR THE REQUEST
The applicant states that there is a need for health care services in Albemarle County that will
continue to increase as the elderly population continues to expand. Furthermore, the applicant
states that he has applied for a certificate of public need to build the proposed 90 -bed nursing home
and that its issuance validates the need for more nursing home and rehabilitative services in this
portion of the County.
ZMA 2011 - 00006, Albemarle Health and Rehab Center, SP 2011 - 00014, Nursing Home
Planning Commission Public Hearing, October 18, 2011
Staff Report, Page 3
PLANNING AND ZONING HISTORY
There is an existing 2 story house, built in 1939 located on the property. There is no zoning history
on this property.
COMPREHENSIVE PLAN
Land Use Plan:
The Comprehensive Plan shows this area primarily as Transitional and a smaller area is
designated Urban Density Residential in Neighborhood 4. The purpose /intent of the Transitional
designation is to provide for neighborhood -scale commercial uses, offices, townhouses and
apartments (6.01 -34 units /acre). Urban Density Residential allows residential (6.01 -34 units /acre);
and supporting uses such as religious institutions, schools, commercial, office, and service uses.
Staff's comments below address how well the proposal conforms to the Comprehensive Plan. Then,
staff addresses how well the proposal conforms to the Neighborhood Model. Finally, staff
addresses how well the proposal meets the guidelines in the Economic Vitality Action Plan. Specific
requirements or recommendations in this section are in bold italics.
Staff believes the proposed use is consistent with the Comprehensive Plan designation for this site.
The character of the surrounding neighborhood provides a variety of mixed uses. A nursing home
facility would not necessarily be out of character in this location.
The Neighborhood Model: Staff's analysis below indicates how well the proposed development
meets the 12 principles of the Neighborhood Model:
Pedestrian Orientation
The application plan shows proposed sidewalks throughout
the site, and stairs are shown near the east corner of the
building. The stairs appear to be located within the sidewalk
area. It is not clear how the stairs and sidewalk will work. It is
also not clear if the entrance road from the fire /rescue station
to the site will have sidewalks? Additional information is
needed in order to know if this principle is addressed.
recommendation ?)
Neighborhood Friendly
The street is not really a street, but a travelway and parking
Streets and Paths
area. This principle is not addressed.
Interconnected Streets and
This site has one access. It appears the existing access to
Transportation Networks
the site will be closed off. Access easements will need to be
provided from adjacent property owner with regards to the
proposed road. Since this is the only access shown to the
property, it is vital that the applicant provides evidence that
easements will be provided by the adjacent property owners.
This principle needs to be addressed. No access is being
provided to adjacent properties (property to the north).
Evidence needs to be provided that shows an access
easement will be used for the intended purpose. Provide
additional access to the site. recommendation?
Relegated Parking
The parking as shown on the plan is not relegated. The
parking is located on the periphery of the building and as
shown will be one of the first things one sees when entering
the site. A redesign of the site and layout could improve
this. (recommendation ?)
Parks and Open Space
This plan does not show open space for use by residents
ZMA 2011 - 00006, Albemarle Health and Rehab Center, SP 2011 - 00014, Nursing Home
Planning Commission Public Hearing, October 18, 2011
Staff Report, Page 4
Economic Vitality Action Plan
The primary goal of the County's Economic Vitality Action Plan is to:
Increase the County's economic vitality and future revenues through economic development by
expanding the commercial tax base and supporting the creation of quality jobs for local
residents. This Plan is developed for the benefit and economic well being, first, of current local
residents and existing local businesses.
The proposed Albemarle Health and Rehab Center (nursing home facility) would support the Plan
by providing additional employment, and housing and rehabilitative services for the elderly
population in the area.
STAFF COMMENT
Relationship between the application and the purpose and intent of the requested zoning
district: The following section is an excerpt from the Zoning Ordinance:
PD -MC districts are hereby created and may hereafter be established by amendment of the
zoning map to permit development of large -scale commercial areas with a broad range of
ZMA 2011 - 00006, Albemarle Health and Rehab Center, SP 2011 - 00014, Nursing Home
Planning Commission Public Hearing, October 18, 2011
Staff Report, Page 5
and /or employees. This principle needs to be addressed.
recommendation ?)
Neighborhood Centers
There is a shopping center, several schools, and the
fire /rescue station located in the vicinity with office /meeting
space. Not applicable.
Buildings and Spaces of
No building elevations have been provided with the rezoning.
Human Scale
However, one -story buildings are appropriate for this type of
facility /use. It is not clear whether the proposed building and
spaces are of human scale. The square footage of the
building takes up the entire site, requiring off -site grading,
retaining walls, and stormwater management. The proposed
site design appears to be overbuilt. Revising the size of
the building to be smaller could allow the applicant to
build on the property without needing permission for
grading and other easements from adjacent property
owners. (recommendation ?)
Mixture of Uses
There are no mixture of uses within this property. However,
with the proximity of other commercial and residential uses in
close proximity to this property, staff does not see this as a
major issue.
Mixture of Housing Types
This is not applicable, given the type of facility proposed.
and Affordability
Redevelopment
This principle is not applicable.
Site Planning that Respects
A fair amount of grading is proposed to the adjacent parcels,
Terrain
not owned by the applicant in order to complete the proposed
development. Retaining walls are also proposed on the site.
As previously stated, the building footprint takes up most of
the property. Staff suggests minimizing the development
on the site in order to reduce the need for disturbances
on adjacent properties. Minimal disturbance to the
terrain is suggested. (recommendation)
Clear Boundaries with the
This principle is not applicable.
Rural Areas
Economic Vitality Action Plan
The primary goal of the County's Economic Vitality Action Plan is to:
Increase the County's economic vitality and future revenues through economic development by
expanding the commercial tax base and supporting the creation of quality jobs for local
residents. This Plan is developed for the benefit and economic well being, first, of current local
residents and existing local businesses.
The proposed Albemarle Health and Rehab Center (nursing home facility) would support the Plan
by providing additional employment, and housing and rehabilitative services for the elderly
population in the area.
STAFF COMMENT
Relationship between the application and the purpose and intent of the requested zoning
district: The following section is an excerpt from the Zoning Ordinance:
PD -MC districts are hereby created and may hereafter be established by amendment of the
zoning map to permit development of large -scale commercial areas with a broad range of
ZMA 2011 - 00006, Albemarle Health and Rehab Center, SP 2011 - 00014, Nursing Home
Planning Commission Public Hearing, October 18, 2011
Staff Report, Page 5
commercial uses under a unified planned approach. It is intended that PD -MC districts be
established on major highways in the urban area and communities in the comprehensive
plan. In recognition that such large -scale development may substantially reduce the
functional integrity and safety of public roads if permitted with unplanned access, it is
intended that multiple access to existing public roads be discouraged and that development
and access be oriented toward an internal road system having carefully planned
intersections with existing public roads.
This property is zoned R -1, which allows residential uses at a density of 1 unit per acre. Large -scale
commercial uses; and residential by special use permit at a density of 15 units /acre are allowed in
the PD -MC Planned Development Mixed Commercial zoning district. A special use permit under
Section 24.2.2(7) of zoning ordinance for hospitals, nursing homes, and convalescent homes uses
is needed for the nursing home facility.
Staff believes with revisions, the proposal could meet the intent of the Planned Development Mixed
Commercial (PD -MC) district; however, the existing proposal leaves several unanswered questions.
The applicant has not addressed the following key elements needed in order to determine the
appropriateness of this proposal at this location:
The proposed development of the site appears to be overdeveloped as evidenced by the following:
Off -site grading and construction easements, which are needed to construct a retaining wall,
access road, and stormwater management; the applicant has not provided evidence from
the adjacent property owners giving permission to allow grading and easements on their
property.
The applicant is requesting a waiver for the minimum yard requirements, and required
buffers and landscaping.
In addition to the various site constraints previously listed, the applicant wishes to exceed
the allowed maximum parking by more than 20 %.
Staff does not believe this proposal is an example of "appropriate and harmonious physical
development" or "creative design."
Public need and justification for the change:
The proposed addition of a nursing home facility in this portion of the County would be beneficial for
the growing elderly population. A nursing home facility in this location is justifiable since there is no
other similar facility in this portion of the County. However, the proposal depicts a site that is
overbuilt. A revised design and layout of the site could make this facility more appropriate at this
location.
Impact on Environmental, Cultural, and Historic Resources:
There is no impact on cultural or historic resources. There are no significant environmental features
impacted by this development. However the intensive development of the site is requiring other
land on other properties to be impacted. With appropriate scaling the level of development on this
site would avoid these impacts.
Anticipated impact on public facilities and services:
Streets:
Off -site grading and access easements will be required for the grading on adjacent property owned
by Albemarle County (Cale Elementary and Monticello Fire - Rescue Station road /site). It is
recommended that the applicant obtain the appropriate agreements from adjacent property owners
to allow the improvements that would occur on their property. It is also recommended that the plan
be revised to show design of the ultimate road section in this location, from Mill Creek Drive to the
ZMA 2011 - 00006, Albemarle Health and Rehab Center, SP 2011 - 00014, Nursing Home
Planning Commission Public Hearing, October 18, 2011
Staff Report, Page 6
development entrance. This road section was shown on the Fire Station plans and prior county
planning documents.
Staff is recommending that the road be built to state standards and reserved for future dedication
upon demand of the county. The applicant has not addressed either the road design to state
standards or reservation of right of way at this time.
Staff has recommended that the applicant consider providing access to at least one other adjacent
site.
See Attachment E for VDOT comment.
Schools: No residential units are proposed, so no impacts are expected on the schools. See
Attachment F for school comments. School representatives have noted that the applicant has not
contacted the Schools and Education Department regarding the needed grading easements.
Fire and Rescue: The Monticello Fire /Rescue Station off Mill Creek Drive is the nearest station and
is located just north to this site.
Utilities:
The sanitary sewer and water lines and easements should consider the county's long range plans
for the property.
The site will be serviced by public water and sewer. No immediate or significant service capacity
issues have been identified by Rivanna Water and Sewer Authority (RWSA). (See Attachment G )
Albemarle County Service Authority (ACSA) comments are attached (Attachment H).
Anticipated impact on nearby and surrounding properties:
As previously mentioned in this report, this proposal anticipates grading and easements on adjacent
properties. A stormwater facility is proposed on the adjacent school property. Access onto this
property needs to be provided via the existing fire /rescue property. Permission or agreements from
the adjacent property owners have not been provided verifying that these activities will be allowed.
An additional impact anticipated on the surrounding properties is an increase in traffic once the
nursing home facility is constructed and occupied.
PROFFERS
The applicant has not provided proffers. Staff believes there are opportunities for appropriate
proffers that should be included with this rezoning application request. For example, some
permitted uses could be proffered out, site design revisions, supporting facilities, access, etc.
Waivers
Waiver of Section 21.7 (b), Minimum Yard Requirements:
The applicant is requesting a waiver of Chapter 18, Section 21.7 (b) of the Zoning Ordinance, which
requires that no portion of any structure in a commercial district be located closer than 50 feet to
any residential or rural area district.
Because the proposed building takes up most of the site, there are areas where the building will
encroach on an adjacent residential district. An area where this occurs is the adjacent residual
parcel subdivided from the subject. It is unknown what will occur with this parcel. If this waiver is to
be granted, some form of a buffer should occur in this portion of the site to provide privacy and
noise attenuation from a potential residence that could be developed on the adjacent parcel (TMP:
ZMA 2011 - 00006, Albemarle Health and Rehab Center, SP 2011 - 00014, Nursing Home
Planning Commission Public Hearing, October 18, 2011
Staff Report, Page 7
91 -12). Parcel 91 -1, owned by the Albemarle County Service Authority, also has a portion of
undeveloped land that is zoned R -1.
The applicant states that not having an actual residence on the adjacent parcels even though they
are located in residential districts justifies the encroachment. Staff believes that in this instance the
encroachment relates to a parcel that is vacant and could develop with a residential use.
Furthermore staff questions the intent of the adjacent residual parcel, which the applicant is
proposing to subdivide from the parcel, particularly since this portion of the property could be used
to help accommodate the proposed development and eliminate or reduce the need for off -site
grading, construction, stormwater and waivers of buffers, landscaping and yard requirements.
(See Attachment 1)
Staff does not recommend approval of the waiver. Redesign of the site and /or a smaller building
size could help relieve this issue.
Waiver of Section 21.7 (C), Required Buffers:
The applicant is requesting a waiver of Chapter 18, Section 21.7 (C) of the Zoning Ordinance,
which requires the maintenance of a 20 foot undisturbed buffer between residential and commercial
properties in order to provide privacy and noise attenuation for residences from the activity of
commercial uses.
The proposed design layout of the site is such that the travelway which is right up against the
property line will encroach 15 feet in what should be a 20 foot buffer. With the exception of the
Dominion Crane and Rigging Inc. (TMP: 91 -1 D) site, which is zoned Light Industrial, all other
adjacent properties are zoned for residential uses, but do not actually have residential uses on
them.
The applicant justifies his request for a waiver because even though the adjacent properties are
zoned for residential uses, none of them actually have residential uses on them. Staff believes
some type of buffer or condition for a future buffer needs to be in place in case any or all of the
adjacent properties develop or redevelop with residential uses. Also, all the adjacent properties
except for the Dominion Crane and Rigging Inc. property are zoned for residential use. The
Comprehensive Plan Land Use Plan also designates all adjacent properties for residential uses with
the exception of a small portion of the Dominion Crane and Rigging Inc. property and the Cale
Elementary School property which are designated for Institutional uses. Fencing or landscaping
could be provided in order to provide privacy and noise attenuation for the adjacent properties. A re-
design of the layout of this site could help the fact that the applicant is overdeveloping on the parcel.
Staff does not recommend approval of the waiver. The applicant needs to provide some form of
buffer or the ability to provide a buffer should the need for a buffer become an issue.
Waiver of Section 32.7.9.8 (c) Required Screening
The applicant is requesting a waiver of Chapter 18, Section 32.7.9.8 (C) of the Zoning Ordinance,
which requires screening of commercial uses from adjacent residential and rural areas districts. The
Zoning Ordinance requires parking lots consisting of four (4) spaces or more be screened from
adjacent residential and rural areas districts.
The applicant states that waiving the required screening will promote efficient land use, permit a
unique site to be developed with a unique use at a unique location. The applicant describes the
adjacent school and utility uses as not accessible to the public from the subject property due to
topography of the land. While this may be accurate, screening not only protects the residential and
ZMA 2011 - 00006, Albemarle Health and Rehab Center, SP 2011 - 00014, Nursing Home
Planning Commission Public Hearing, October 18, 2011
Staff Report, Page 8
rural areas from the disturbances of a commercial use, but can be advantageous from a visual
standpoint for adjacent properties.
Again staff believes that some level of screening would be helpful, particularly with adjacent
properties that could be developed. If the site design were revised and parking was relegated some
of these issues on the subject parcel could be resolved or at least the impact might not be as
extensive with regards to the adjacent parcels.
Staff cannot recommend approval of the waiver at this time. Redesign of the site and a smaller
building could help relieve some of the issues that the applicant is requesting be waived. It appears
this site is too small. Creative design of the site and building could be helpful to accommodate the
level of use proposed in this application. While staff does not believe full screening of the nursing
home use is needed, some level of screening would be beneficial given the intensive level of
development and the proximity of parking to the property lines. Appropriate conditions for the
special use permit could also help address this concern.
Waiver of Section 4.12.4(a), Exceeding the maximum parking by more than 20%
The applicant is requesting a waiver of Chapter 18, Section 4.12.4(a) of the Zoning Ordinance,
which requires that the amount of parking spaces in a parking area not exceed the number of
spaces required by more than twenty (20) percent.
The applicant feels that the proposed use will need more parking than the required amount. The
information provided in the waiver request is not clear and staff needs additional information in
order to complete the review of this waiver request; therefore, staff cannot recommend approval of
this waiver at this time. (See Attachment J)
Staff Comment on SP 2011 - 00014 - Request for Nursing Home Facility Use in the PD-
MC Planned Development Mixed Commercial District
Section 31.6 of the Zoning Ordinance below requires that special use permits be assessed as
follows:
Will the use be of substantial detriment to adjacent property?
No substantial detriment to adjacent properties is anticipated from the requested nursing
home and rehabilitative services use. However, the plan shows off -site improvements and
no agreements have been secured from any adjacent owners for this off -site work.
Will the character of the zoning district change with this use?
The character of the zoning district could change and become more commercial in character than
the residential intent of the R -1, residential district. However, staff does not believe the proposed
use will be detrimental to the area, since there is a true mix of uses in the vicinity already, and the
proposed use and zoning district is generally in keeping with the surrounding character of the
neighborhood.
Will the use be in harmony with the purpose and intent of the zoning ordinance?
The PD -MC district has characteristics that tend to be more large scale commercial in
nature than residential. However, nursing home facility uses are permitted in the PD -MC
district with a special use permit. Although at a smaller scale, the proposed nursing home
facility is in harmony with the purpose and intent of the zoning ordinance.
Will the use be in harmony with the uses permitted by right in the district?
This area contains a wide mix of existing uses; some public facilities, small scale strip
commercial development and some residential uses. Nursing home uses are allowed in the
ZMA 2011 - 00006, Albemarle Health and Rehab Center, SP 2011 - 00014, Nursing Home
Planning Commission Public Hearing, October 18, 2011
Staff Report, Page 9
PD -MC district with a special use permit. With the appropriate buffers, the nursing home
use seems appropriate with the permitted by right uses in the district.
Will the use comply with the additional regulations provided in Section 5.0 of this ordinance?
Section 5.1.13 Rest Home, Nursing Home, Convalescent Home, Orphanage is applicable
to the proposed nursing home use and each regulation is addressed below
a. Such uses shall be provided in locations where the physical surroundings are
compatible to the particular area;
The proposed use is located in the Development Area.
b. No such use shall be established in any area either by right or by special use
permit until the Albemarle County fire official has determined that adequate
fire protection is available to such use;
The proposed use is located adjacent to the Monticello fire /rescue facility.
c. Generally such uses should be located in proximity to or in short response
time to emergency medical and fire protection facilities. Uses for the elderly
and handicapped should be convenient to shopping, social, education and
cultural uses;
The proposed use is adjacent to the Monticello fire /rescue station. Across Mill Creek
Drive, which is the access road for the proposed site, is a shopping center.
Downtown Charlottesville, PVCC, Monticello High school, Cale Elementary school,
and Tandem Friends School are all located fairly nearby.
d. No such use shall be operated without approval and, where appropriate,
licensing by such agencies as the Virginia Department of Welfare, the Virginia
Department of Health, and other such appropriate local, state and federal
agencies as may have authority in a particular case.
The appropriate approval and licensing will be completed by the applicant.
Will the public health, safety and general welfare of the community be protected if the use is
approved?
The public health, safety, and general welfare of the community are protected through the
special use permit process which assures that the proposed use is appropriate in the
location requested. There are no safety concerns with the proposed nursing home use.
SUMMARY
Staff has identified the following factors, which are favorable to this rezoning request:
1. Development of the property as a nursing home is consistent with the Comprehensive
Plan designation.
2. This rezoning request provides a need and service for the elderly in a portion of the
County that does not have a similar use.
Staff has found the following factors unfavorable to this rezoning:
1. The proposal for the site is so overdeveloped that the design requires
grading, and easements, on the adjacent properties for retaining walls, access road, and
stormwater management.
ZMA 2011 - 00006, Albemarle Health and Rehab Center, SP 2011 - 00014, Nursing Home
Planning Commission Public Hearing, October 18, 2011
Staff Report, Page 10
2. No permission has been received from adjacent property allowing permission
for the necessary grading /easements on the subject property. Without permission this
project will not be able to be developed as proposed.
3. The applicant is requesting a waiver to provide over 20 percent more parking
on the site than what is required by the Zoning Ordinance.
4. Multiple waiver requests for buffer, landscape and minimum yard requirements (along
with off -site stormwater management and grading indicates the proposal overdevelops
the site.
RECOMMENDATION
Staff believes that a nursing home facility proposal could be made in this location that would be in
keeping with the County's Comprehensive Plan. However, based on the factors noted as
unfavorable in this report, staff recommends denial of this rezoning.
Staff recommends denial of SP 2011 - 00014, Albemarle Health and Rehab Center based on the
factors noted as unfavorable in this report.
Should the Commission determine that the nursing home use is appropriate; the items listed below
should be addressed prior to approval of the zoning map amendment and special use permit:
1. The applicant is showing too much development for the site; the square footage
of the building should be reduced so that the building and sufficient parking meet
ordinance requirements. If any easements are necessary from adjacent property
owners, the applicant should show that the adjacent owners are willing to grant these
easement(s) in order to demonstrate that he will have a developable project.
2. Details regarding the road from the fire /rescue station to the direct entrance to the
site need to be worked out with the County. Will there be a reservation for future dedication
and built to state standards? If this is a private road a maintenance agreement will need to
be worked out.
3. Provide information from the Thomas Jefferson Foundation confirming that this
project is not visible from Monticello.
4. Provide clarification regarding the parking waiver request.
5. Based on existing facilities similar to the proposed use, JAUNT would expect to
make frequent trips to serve residents. JAUNT's preference is to have a designated building
entrance for JAUNT to use, with a covered (11 ft min vertical clearance), accessible bus
loading area. Please provide this detail on your plan.
WAIVERS
Staff recommends denial of waiver requests of Section 21.7(b) of Zoning Ordinance for Minimum
Yard Requirements; Section 21.7 (C) for Required Buffers; Section 32.7.9.8 (c ) for Required
Screening; and Section 4.12.4(a for Exceeding the maximum parking by more than 20% based on
the factors noted as unfavorable in this report.
PLANNING COMMISSION MOTION — Zoning Map Amendment:
A. Should a Planning Commissioner choose to recommend approval of this zoning map
amendment with waivers:
Move to recommend approval of ZMA 2011 - 00006, Albemarle Health and Rehab Center with
waivers.
B. Should a Planning Commissioner choose to recommend denial of this zoning map
amendment with waivers:
ZMA 2011 - 00006, Albemarle Health and Rehab Center, SP 2011 - 00014, Nursing Home
Planning Commission Public Hearing, October 18, 2011
Staff Report, Page 11
Move to recommend denial of ZMA 2011 - 00006, Albemarle Health and Rehab Center with
waivers, based on the recommendation of staff. Should a commissioner motion to recommend
denial, he or she should state the reason(s) for recommending denial.
PLANNING COMMISSION MOTION — Special Use Permit:
A. Should a Planning Commissioner choose to recommend approval of this special use permit
with waivers:
Move to recommend approval of SP 2011 - 00014, Albemarle Health and Rehab Center with
waivers.
B. Should a Planning Commissioner choose to recommend denial of this special use permit with
waivers:
Move to recommend denial of SP 2011 - 00014, Albemarle Health and Rehab Center with
waivers based on the recommendation of staff. Should a commissioner motion to recommend
denial, he or she should state the reason(s) for recommending denial.
ATTACHMENT A: Location Map
ATTACHMENT B: Zoning Map
ATTACHMENT C: Comprehensive Plan Land Use Plan Map
ATTACHMENT D: Application Plan, dated June 20, 2011
ATTACHMENT E: Electronic Mail from Joel DeNunzio, dated July 28, 2011
ATTACHMENT F: Memo from Joseph P. Letteri, dated July 14, 2011
ATTACHMENT G: Electronic Mail from Victoria Fort, dated July 14, 2011
ATTACHMENT H: Electronic Mail from Alex Morrison, dated July 15, 2011
ATTACHMENT I: Letter and waiver requests from Justin Shimp, dated August 30, 2011
ATTACHMENT J: Memo from Francis MacCall, dated September 30. 2011
ZMA 2011 - 00006, Albemarle Health and Rehab Center, SP 2011 - 00014, Nursing Home
Planning Commission Public Hearing, October 18, 2011
Staff Report, Page 12