Loading...
HomeMy WebLinkAboutSP201200015 Legacy Document 2012-08-08 (5)a (3) NEW VERIZON WIRELESS ANTENNAS HEIGHT = 135'1 AGL [652.9' AMSL] ® RAD (3) NEW VERIZON WIRELESS ANTENNAS HEIGHT = 126'1 AGL [643.9' AMSL] ® RAD INSTALL NEW MESSENGER TUBE(S) ON NORTHEAST SIDE OF TOWER TO ELIMINATE VISUAL IMPACT FROM BARRACKS ROAD. NEW LTE CABINET NEW DUCT BANK EXISTING CABINET EXISTING DUCT BANK ELEVATION VIEW LOOKING WEST NO SCALE TOP OF TOWER EXTENSION Ah ANTENNA NOTES HEIGHT = 139'1 AGL [656.9' AMSL] NEW TOWER EXTENSION DESIGNED 1. ANTENNAS ARE TYPICAL FLUSH —MOUNT DESIGN USING BY DOMINION VIRGINIA POWER MOUNTING COLLAR, BRACKET AND PIPE MOUNTS. 2. FINAL MOUNTING DESIGN MAY VARY SLIGHTLY DEPENDING ON TOP OF EXISTING POWER TOWER OL AVAILABILITY AND MANUFACTURER. HEIGHT = 120.9' AGL [638.8" AMSL) 3. PROPOSED ANTENNAS MODEL — ANTEL BXA- 70063/8CF (3) EXISTING VERIZON WIRELESS ANTENNAS TO BE REMOVED DIMENSIONS — 94.6 "(H) X 11.2 "(W) X 4.5 "(D) HEIGHT = 115 f AGL [632.9' AMSL) 9 RAD � MODEL — ANTEL BXD- 908090120CF DIMENSIONS — 94.7'(H) X 16.7 "(W) X 5.9 "(D) EXISTING DOMINION VIRGINIA POWER TRANSMISSION TOWER #291- 30/33 -30 MESSENGER TUBE GRADE 5179" AMSL R' -n" NOTES 1. NO COMMERCIAL ADVERTISING MATERIAL WILL BE USED IN CONJUNCTION WITH THE NEW TOWER. - 2. ALL VERTICAL COAXIAL CABLES WILL BE RUN INSIDE OF THE MESSENGER TUBES ATTACHED TO THE EXISTING TRANSMISSION TOWER. 3. ALL VERTICAL CABLES, WIRING, AND SIMILAR ATTACHMENTS ON THE OUTSIDE OF THE POLE SHALL BE PLACED TO FACE THE INTERIOR OF THE PROPERTY, AWAY FROM PUBLIC VIEW. 4. NO POINT ON THE FACE OF THE ANTENNA SHALL PROJECT MORE THAN 12 INCHES FROM THE FACE OF THE EXISTING STRUCTURE TO WHICH IT IS ATTACHED UNISTRUT PIPE /CONDUIT CLAMP P1119 OR P2558 -35 (GALV.) (TYP). FOLLOW MANUFACTURE RECOMMENDATIONS FOR BOLT TORQUE 3 1/2" O.D. POST (TYP) 1TF 8' UTILITY SERVICE STAND NO SCALE A MIN 3000 PSI CONCRETE 6" X 20" STUB UP AREA .............. J —.'. ..... A .......... �. -I..I . ........................I..I.I. ' .I . 2, -2„ I .................. L------ - -____ . -- - - - -"J . ............................... 12, -0„ N � fV NOTE: CONTRACTOR TO COORDINATE CONDUIT STUB —UPS THROUGH THE STUB UP AREA TO ENSURE NO REINFORCING BARS ARE CUT. CONCRETE TO BE PLACED AROUND THE CONDUITS, AFTER CONDUIT STUB —UPS ARE INSTALLED WITHIN THE STUB UP AREA. GENERATOR PAD DETAIL NO SCALE EL UNISTRUT, G (TYP) )2860 -10 END CAPS (TYP) 0 PIPE (GALV) dG (TYP) FINISH GRADE 1UNDATION 2'-0' #5 AT 18" O.C. WITH 3" CLEAR COVER AT PAD EDGES �� 1/2" CONTINUOUS 6 "x6 "— W2.9xW2.9 ^ CHAMFER WELDED WIRE FABRIC N0.57 COARSE AGGREGATE 0 C . NO.57 COARSE AGGREGATE 6" MINIMUM COMPACTED SUBGRADE C3 m 8" w GENERATOR PAD SECTION A -A (1) #4 CONT NO SCALE rchitecture & Engineers 1331 L STREET, 1' SUITE i WASHINGTON, DC 201 202461-3260 FAX 202.461.3 WWW.CLARKNEXSEN.0 % venZoon"3 wireless 1831 RADY COURT RICHMOND, VA 23222 JUSTIN Y. YOON Lic. No. 42897 O ONAL SREINFO.: COLTHURST LTE (4G) UPGRADE 1575 INGLERIDGE FARM CHARLOTTESVILLE, VA 22901 ALBEMARLE COUNTY DESIGN: SPP DRAWN: KAW REVIEW: CCc TTV DATE 111 COMM. NO. 3036NN SUBMITTALS SYK DESQUPI'ION DATE i ENLARGED SFfE PLAN 5/3/11 2 SFfE PLAN SUBMITTAL 5/25/11 REVISED SITE PLAN 9/23/11 4 PRO MNARY CONSTRUCNON DRAWMS 11/18/11 a RE11SED PREUM. CONSTRUCTION DW05 1/2/12 e PLICATION DRAWINGS 4/20/12 FINAL CONSTRUCTION DRAWINGS 5/16/12 Z% REVD FINAL CONSF DRAWINGS 6/25/12 9-ar NOME ELEVATION VIEW SHEET NO.: C -3