Loading...
HomeMy WebLinkAboutARB201200129 Legacy Document 2012-10-19 (2)SIGN DETAIL LJ APPROVED ❑ APPROVED W/REVISIONS ❑ RESUBMIT X FRONT ELEVATION ALBEMARLE COUNTY SIGN CODE: WALL SIGNS - ALLOWED 1.5 SF PER LINEAR FOOT OF BUILDING FRONTAGE - NTE 200 SF FOR ALL WALL SIGNS NOTE: THE LEVEL OF ILLUMINATION PROVIDED BY THE LED LIGHTS WILL NOT EXCEED THE ILLUMINATION PRODUCED BY A SINGLE STROKE OF 30 MILLIAMP(MA) NEON. SCALE: 3/32 " =V -0" Client: The Fresh Market SIGN PLACEMENT MAY CHANGE Drawing scale: Proportional j�7� 2165 Seminole Trail Layout by: Marcie Rengifo ❑x Preliminary Drawing Location: Albemarle Square we cannot guarantees =aa color matcbas. Drawing location: JN80uu u 1EDW Charlottesville, VA 22901 phone: (800)482 -6603 x114 ❑ Final Drawing Al l sizes and dimensions are illustrated for Charlottesville, VA 22901 clienfe conception of projea and are not to be ��� fax: (434)974 -6898 Phone /Email: understood asbaingexacl size ofexaclscale. Revision #: marcie@htsva.com PAGE 1 OF 2 Copyright Warning: This is an original unpublished design created by Hightech Signs. It is submitted for your personal consideration, it is not to be shown to anyone outside your organization nor is it to be reproduced or exhibited in any fashion whatsoever. It remains the property of Hightech Signs until legally purchased. SIGN DETAIL Lj APPROVED Lj APPROVED W/REVISIONS L RESUBMIT X MANUFACTURING /INSTALLATION NOTE: LETTERS TO BE MADE SEPARATELY BUT APPEAR CONNECTED WHEN INSTALLED SIGN TYPE &,% MANUFACTURE AND INSTALL ONE (1) SET FACE -LIT INTERNALLY ILLUMINATED CHANNEL LETTER LAYOUT 139 SQ.FT. Scale: 3/16"=1'-0" LETTER SPECIFICATIONS: INDIVIDUAL, INTERNALLY ILLUMINATED CHANNEL LETTERS CHANNELS FABRICATED WITH ALUMINUM INTERIOR OF LETTERS FINISHED WHITE FOR EVEN LIGHT DISTRIBUTION. LOW VOLTAGE POWER SOURCE FACES OF CYRO ACRYLIC #SG 5200 -0 GREEN BANDED WITH A 1 "GREEN TRIM CAP MOLDING STAND OFF FROM WALL IS 1/2" NOTE: PRIMARY ELECTRIC TO SIGN SITE (BY OTHERS) NOTE: THE LEVEL OF ILLUMINATION PROVIDED BY THE LED LIGHTS WILL NOT EXCEED THE ILLUMINATION PRODUCED BY A SINGLE STROKE OF 30 MILLIAMP(MA) NEON. ly... /�— NON—STANDARD CUSTOM SIZE i 28' -6" E FRESH MANUFACTURING /INSTALLATION NOTE: LETTERS TO BE MADE SEPARATELY BUT APPEAR CONNECTED WHEN INSTALLED SIGN -E A MANUFACTURE AND INSTALL ONE (1) SET FACE -LIT INTERNALLY ILLUMINATED CHANNEL LETTER LAYOUT 52.25 SQ.FT. M Scale: 3/16 " =1' -0" LETTER SPECIFICATIONS: INDIVIDUAL, INTERNALLY ILLUMINATED CHANNEL LETTERS CHANNELS FABRICATED WITH ALUMINUM INTERIOR OF LETTERS FINISHED WHITE FOR EVEN LIGHT DISTRIBUTION. LOW VOLTAGE POWER SOURCE FACES OF CYRO ACRYLIC #SG 5200 -0 GREEN BANDED WITH A 1 "GREEN TRIM CAP MOLDING STAND OFF FROM WALL IS 1/2" NOTE: PRIMARY ELECTRIC TO SIGN SITE (BY OTHERS) MATERIAL FINISH COLORS BRANCH Ya" WEEP HOLES (2 MIN.) (BY OTHERS) FOR SIGN NOTE: WEEP HOLES NOT REQUIRED ON INTERIOR APPLICATIONS EXISTING FASCIA ■ GREEN ■ EStandard EGroon LEDS 90 EMS 9 4 EMS 34 EMS 349 Letter Letter Trim -Cap Internal Returns Faces Faces Illumination NOTE: THE LEVEL OF ILLUMINATION PROVIDED BY THE LED LIGHTS WILL NOT EXCEED THE ILLUMINATION PRODUCED BY A SINGLE STROKE OF 30 MILLIAMP(MA) NEON. ly... /�— NON—STANDARD CUSTOM SIZE i 28' -6" E FRESH MANUFACTURING /INSTALLATION NOTE: LETTERS TO BE MADE SEPARATELY BUT APPEAR CONNECTED WHEN INSTALLED SIGN -E A MANUFACTURE AND INSTALL ONE (1) SET FACE -LIT INTERNALLY ILLUMINATED CHANNEL LETTER LAYOUT 52.25 SQ.FT. M Scale: 3/16 " =1' -0" LETTER SPECIFICATIONS: INDIVIDUAL, INTERNALLY ILLUMINATED CHANNEL LETTERS CHANNELS FABRICATED WITH ALUMINUM INTERIOR OF LETTERS FINISHED WHITE FOR EVEN LIGHT DISTRIBUTION. LOW VOLTAGE POWER SOURCE FACES OF CYRO ACRYLIC #SG 5200 -0 GREEN BANDED WITH A 1 "GREEN TRIM CAP MOLDING STAND OFF FROM WALL IS 1/2" NOTE: PRIMARY ELECTRIC TO SIGN SITE (BY OTHERS) Total: TB•D• Amps # of 120V, 20A Circuits Req'd TB.D ALL BRANCH CIRCUITS SHALL BE DEDICATED TO SIGNS (INCLUDING GROUND AND NEUTRAL) AND SHALL NOT BE SHARED WITH OTHER LOADS. 1/211 5" POWER SUPPLY OUTPUT LEAD OR EXTENDED LEAD USING APPROPRIATE UL LISTED PLTC: Up to 15' = 18AWG / Up to 50' = 14AWG ALUMINUM SPACER J -BOX W/ DISCONNECT 3/16" ACRYLIC WITH SWITCH MOUNTED TO PLASTIC RETAINERS END OF TRANS. BOX L.E.D. ILLUMINATORS AS REQUIRED. .063 ALUM. BACK SEAL ENTRY & EXIT HOLES W/ SILICONE LOW VOLTAGE .040 ALUM. RETURNS POWER SUPPLY J -BOX (BY OTHERS) TRIMCAP MATERIAL FINISH COLORS BRANCH Ya" WEEP HOLES (2 MIN.) (BY OTHERS) FOR SIGN NOTE: WEEP HOLES NOT REQUIRED ON INTERIOR APPLICATIONS EXISTING FASCIA ■ GREEN GREEN ■ EStandarnd EGreen EDS EMS 349 EMS 3490 EMS 349 Letter Letter Trim -Cap Internal Returns Faces Faces Illumination Total: TB•D• Amps # of 120V, 20A Circuits Req'd TB.D ALL BRANCH CIRCUITS SHALL BE DEDICATED TO SIGNS (INCLUDING GROUND AND NEUTRAL) AND SHALL NOT BE SHARED WITH OTHER LOADS. 1/211 5" POWER SUPPLY OUTPUT LEAD OR EXTENDED LEAD USING APPROPRIATE UL LISTED PLTC: Up to 15' = 18AWG / Up to 50' = 14AWG ALUMINUM SPACER J -BOX W/ DISCONNECT 3/16" ACRYLIC WITH SWITCH MOUNTED TO PLASTIC RETAINERS END OF TRANS. BOX L.E.D. ILLUMINATORS AS REQUIRED. .063 ALUM. BACK SEAL ENTRY & EXIT HOLES W/ SILICONE LOW VOLTAGE .040 ALUM. RETURNS POWER SUPPLY J -BOX (BY OTHERS) TRIMCAP BRANCH Ya" WEEP HOLES (2 MIN.) (BY OTHERS) FOR SIGN NOTE: WEEP HOLES NOT REQUIRED ON INTERIOR APPLICATIONS EXISTING FASCIA See notes for requirements DETAIL FOR TYPICAL CHANNEL LETTER WITH ILLUMINATED PLEX FACE W/ REMOTE TRANSFORMER NOTES: NOT TO SCALE 1- All seams to be placed for min. visibility. 2- Install to conform w/ section 600 of NEC. 3- Letters fabricated to UL standards 4- Transformer mounting TBD. in field. 5- Letters to be const. to prevent light leaks. 6- Min. 2 mounting bolts per letter. Branch Circuit: A. All branch circuits for signs must be totally dedicated to signs (including dedicated ground and dedicated neutral per circuit). B. Sign circuits must not be shared with other loads such as lighting, air conditioning, and other equipment. C. Properly sized ground wire that can be traced back to the breaker panel must be provided. D. Number and size of circuits for each sign to meet Federal Heath Sign's requirement. CUSTOMER TO PROVIDE: (For New / Remodel Construction) ADEQUATE BEHIND THE WALL BACKING AND ACCESS AS REQUIRED TO INSTALL SIGNAGE. CUSTOMER TO FORWARD COPY OF FINAL APPROVED SIGNAGE DRAWINGS TO BUILDING SITE CONTACT SO THAT THESE PROVISIONS CAN BE MADE DURING CONSTRUCTION AND PRIOR TO SIGN INSTALL, ALL BRANCH CIRCUITS (PRIMARY ELECTRICAL SERVICE & FINAL CONNECTION) TO EACH SIGN TO BE BY CERTIFIED ELECTRICIAN: A. All branch circuits for signs must be totally dedicated to signs (including dedicated ground and dedicated neutral per circuit). B. Sign circuits must not be shared with other loads such as lighting, air conditioning, and other equipment. C. Properly sized ground wire that can be traced back to the breaker panel must be provided. D. Number and size of circuits for each sign to meet Federal Heath Sign's requirement. INSTALLER IS RESPONSIBLE FOR: PROVIDING AND INSTALLING ALL COMPONENTS REQUIRED TO RUN SECONDARY WIRING (CONNECTORS, GTO CONDUIT, ETC.) TO BE DETERMINED BY LOCAL CODE AND SITE CONDITIONS. PROVIDING ALL NEEDED INSTALLATION HARDWARE AS DETERMINED BY LOCAL CODE AND SITE CONDITIONS. SEALING BUILDING PENETRATIONS WITH SILICONE TO PREVENT MOISTURE PENETRATION @ EXTERIOR LOCATIONS.. Client: The Fresh Market SIGN PLACEMENT MAY CHANGE Drawing scale: Proportional j�7� 2165 Seminole Trail Layout by: Marcie Rengifo ❑x Preliminary Drawing Location: Albemarle Square We cannot guarantee -act colormatcbas. Drawing location: JN80uu u 1EDW Charlottesville, VA 22901 phone: (800)482 -6603 x114 ❑ Final Drawing All sizes and dimensions are illustrated for Charlottesville, VA 22901 client's conception of project and are not to be ��� fax: (434)974 -6898 Phone /Email: understood as beingexacl size ofexaclscale. Revision #: marcie@htsva.com PAGE 2 OF 2 Copyright Warning: This is an original unpublished design created by Hightech Signs. It is submitted for your personal consideration, it is not to be shown to anyone outside your organization nor is it to be reproduced or exhibited in any fashion whatsoever. It remains the property of Hightech Signs until legally purchased.