HomeMy WebLinkAboutSUB201200112 Legacy Document 2013-01-11Christopher Perez From: Mike Myers [mmyers @dominioneng.com] Sent: Monday, December 10, 2012 4:32 PM To: Robbie Gilmer; Howard Lagomarsino Cc: 'Keith Lancaster'; 'Charlie Armstrong'; Shawn Maddox; Megan Yaniglos; Christopher Perez Subject: RE: Dunlora Forest Subdivision (SUB 2012 - 00097) and Lanetown Subdivision (SUB 2012 - 00112) Thanks Robbie, By copy of this email, I have forwarded this information to Albemarle County Planning, Mike Michael Myers, PE, CFM 434 - 979 -8121 x140 (office) 434 - 906 -3161 (mobile) F I {+ Dominion "� ntyineeans & Design, LLC From: Robbie Gilmer [ mailto: rail mer(aOalbemarle.org] Sent: Monday, December 10, 2012 4:23 PM To: Mike Myers; Howard Lagomarsino Cc: Keith Lancaster; Charlie Armstrong; Shawn Maddox Subject: RE: Dunlora Forest Subdivision (SUB 2012 - 00097) and Lanetown Subdivision (SUB 2012 - 00112) Mike, Based on the information provided Albemarle County Fire Rescue will grant the request for the 10 foot setback in both Dunlora Forest and Lanetown Subdivisions. If you need anything else just let us know. Thank you, Robbi e G i I mer Albemarle County Fire Rescue Assist. Fire Marshal 460 Stagecoach Road, Suite F Charlottesville, Va 22902 o- 434 - 296 -5833 c- 434 - 531 -6606 From: Mike Myers [ mailto:mmyers(@dominioneng.com] Sent: Friday, November 30, 2012 12:03 PM To: Howard Lagomarsino; Robbie Gilmer Cc: 'Keith Lancaster'; 'Charlie Armstrong' Subject: Dunlora Forest Subdivision (SUB 2012 - 00097) and Lanetown Subdivision (SUB 2012 - 00112) Howard, Thanks so much to you, Robbie and Shawn for meeting with us on Tuesday to discuss the reduction of side yard setbacks from 15 feet to 10 feet in both the Dunlora Forest (SUB 2012 - 00097) and Lanetown (SUB 2012 - 00112) subdivisions. Please consider this our formal request to allow 10 -foot side yard setbacks in accordance with Albemarle County Zoning Ordinance 4.11.3. Enclosed please find the applicable section of the ISO publication entitled, "Guide for Determination of Needed Fire Flow ". Per this section, the needed fire flow for each subdivision is equal to 1,000 gpm @ 20 psi residual pressure since we will be maintaining at least 20 feet between buildings. Our available flow is 1,979 gpm @ 20 psi residual in Lanetown and is in excess of 2,500 gpm @ 20 psi residual in Dunlora Forest. Based on this, we are respectfully requesting that you provide us documentation that we can forward to Albemarle County that will allow the 10 -foot side yards for each subdivision. Thanks as always for working with us on this, Mike Michael Myers, PE, CFM 434 - 979 -8121 x140 (office) 434 - 906 -3161 (mobile) {+ Dominion fi Engineering & °" Desi+gn, LLC