HomeMy WebLinkAboutARB201300032 Legacy Document 2013-04-16 (2)Site I. D. 4793
Brand Name: Lane Bryant
Address: Shoppers World
Street 100 Shoppers World Court
City, State Charlottesville, VA 22901
11►i
Township Name Albermarle County
Contact Person: Stuart: 434 - 296 -5832 x3024
Keith: x3241 Brent Nelson ARB: x3438
DLORD CONTACTS:
Developer
Contact Craig Smith CSmith @federalrealty.com or
Stuart Biel sbiel @federalrealty.com
Phone: 301 - 998 -8167
NOTICE:
Ono N -1.
- Letter heights preferred in the 30 -36" range and proportional.
- No blade signs allowed at center.
- Window vinyl reviewed on a case by case basis.
SIGN CODE ALLOWANC§d
- All signs are a maximum combined sign area of the linear width
of the tenant space times one and a half (1 1/2), not to exceed
two hundred (200) square feet. Must be channel letters.
- Window signs; not to exceed twenty five (25 %) percent of the
window. Included in maximum allowable area.
- Maximum projection for wall signs is 12 inches.
LANDLORD APPROVAL:
CSI APPROVAL
DATE:
DATE:
L CUSTOM Halo -Lit Channel Letters - (Qty: 1) As. 89209 R2
NQted Shoppers World
•
100 Shoppers World Court
.... •. .. Lane Bryant #4793 Charlottesville, VA 22901
2 - Commercial W94 .609 Rrl Ft. Black Aluminum TBD(1-20A circuit LED TBD Wall N/A N/A
30"
22" 20.125"
DAY VIEW
NIGHT VIEW (HALO -LIT)
FACES AND RETURNS WILL BE OPAQUE. NO LIGHT WILL BE TRANSMITTED THROUGH FACE OR RETURN OF LETTER.
262 1/8"
13 3/4"
102 3/8" 1441/4"
1113/8"
61 /2"
E3 RYA N T\
DISCONNECT SWITCH ON
END OF LETTER "T"
ILLUMINATED LETTERS
Scale: 1/2" = 1' - 0"
LED LAYOUT ONLY TBD
BLACK LETTERS (LIGHT BKGDs)
Scale: Not to Scale
ENERGY DATA
Input Voltage (V DC)
12
Module Level Power (W /ft)
2.0
System Level Power (W /ft)*
2.25
Delivered Lumens (Lm /ft) **
150
System Efficacy (Lm/W)
66
Viewing Angle (0)
120
.050 BLK/WHTALUMINUM RETURNS
OUTSIDE OF LETTER TO BE
Correlated Color Temp (K)
6300
PAINTED BLACK SATIN FINISH
L70 Calculated Life (Hrs) ) * **
99,000
INSIDE OF LETTER TO BE WHITE
Typical Stroke (in) * * **
6
WHITE LEDs ADHERED TO ACRYLIC
BACK FACING FRONT OF LETTERS
Operating Temperature
( -40) to 60 °C /
( -40) to 140 of
3116" WHITE TRANSLUSCENT LEXAN
* System power consumption, which includes power supply losses.
** Estimated light output under application operating conditions.
* ** Projected LED lumen maintenance based on the IED TM -21 model.
Calculation is based on 10,000 hours of LM -80 data. Module average
ambient temperature is 25 °C.
* * * *For 5inch deep can.
I— — — — — — — — — — — — — — — — — — — — — — — — — -
BRYANTI
54.609 Sq. Ft. - NTS
NOTE: UL sticker has to be present.
Sign manufacturer's decals cannot be present. (No Jones labels allowed)
.090 ALUMINUM REMOVABLE FACE
BLACK ALUMINUM SATIN FINISH
NON- CORROSIVE MOUNTING
HARDWARE AND SPACERS
TO SUIT WALL
1/4" DIAMETER DRAIN HOLE W
LIGHT BAFFLE (MIN. 2 PER LETTER;
BLACK HALO -LIT CHANNEL LETTERS DETAIL VIEW
Scale: Not to Scale
LOW VOLTAGE WIRING
THRU SLEEVE TO
REMOTELY MOUNTED
120V x 12V POWER PACK
WEATHER PROOF
POWER SUPPLY
DISCONECT SWITCH SHALL
BE INSTALLED SIDEWAYS
FOR TAMPER RESISTANCE
20 AMP PRIMARY ELECTRIC
CIRCUITS BROUGHT TO SIGN AREA
w/ FINAL CONNECTION BY SIGN INSTALLER
WHERE LOCAL CODES ALLOW
6' WHIP LENGTH REQUIRED
SILICONE CAULK
ALL PENETRATIONS
Conceptual Artwork
Amanda Otto
Date
04.08.13
Sales
File Location
Construction Drawing
Date
0
Project Manager
Janet Piccione
IIIIIIIIIIIIIII111F
Revision Notes
DATE INITIALS NOTES
03.13.13 ATO Order #, Back Door Vinyl
04.08.13 ATO New Custom Ltr Dim.
This Drawing Last Updated on:
04.08.13
CSI REQUIRES THAT DISCONNECT SWITCH
BE LOCATED AT POINT OF POWER SUPPLY
UNLESS CODE DICTATES OTHERWISE
ALL SIGN WIRING AND DISCONNECT SWITCH
TO ADHERE TO NEC CODE 600.6
U.L. NOTE
CODES. THIS INCLUDES PROPER GROUNDING
AND BONDING OF SIGN.
THIS SIGN IS INTENDED TO BE INSTALLED IN
ACCORDANCE WITH THE REQUIREMENTSOF
ARTICLE 600 OF THE NATIONAL ELECTRICAL
CODE AND /OR OTHER APPLICABLE LOCAL
PRELIMINARY DRAWING
ALL CONDITIONS MUST BE FIELD VERIFIED
PRIOR TO FABRICATION
I LLApproval I
CSI Approval
Back Board for Mountina Urs
=2
-Commercial 1 N/A 1 N/A JL N/A
BACKER PANEL PROVIDED BY LANDLORD
42"
As Noted & 8929 RZ Shoppers World
100 Shoppers World Court
Lane Bryant #4793 Charlottesville, VA 22901
'A ■ N/A ■ Wall ■ N/A ■ N/A
280"
Scale: ' /2" = 1' - 0"
Letters (Previous Page) Mounted to Back Board for Mounting to Slanted Roof painted Gray PMS 423C
Mounting Template for Itrs TBD Pre -Drill holes prior to painting.
NOTE: BOARD DIMENSIONS & ATTACHMENT METHOD TBD
LL Approval
CSI Approval
Conceptual Artwork
Amanda Otto
Date
03.13.13
Sales
File Location
Construction Drawing
Date
Project Manager
Janet Piccione
Revision Notes
DATE INITIALS NOTES
03.13.13 ATO Order #, Back Door Vinyl
04.08.13 ATO New Custom Ltr Dim.
his Drawing Last Updated on
04.08.13
CSI REQUIRES THAT DISCONNECT SWITCH
BE LOCATED AT POINT OF POWER SUPPLY
UNLESS CODE DICTATES OTHERWISE
ALL SIGN WIRING AND DISCONNECT SWITCH
TO ADHERE TO NEC CODE 600.6
U.L. NOTE
CODES. THIS INCLUDES PROPER GROUNDING
AND BONDING OF SIGN.
THIS SIGN IS INTENDED TO BE INSTALLED IN
ACCORDANCE WITH THE REQUIREMENTSOF
ARTICLE 600 OF THE NATIONAL ELECTRICAL
CODE AND /OR OTHER APPLICABLE LOCAL
STORE ELEVATION
2 - Commercial / N/A
U1
A
A ■ 20
wall
0
Store Elevation - Day View (NTS) CL
*FIELD SURVEY EXISTING CONDITIONS FOR INSTALLATION
Store Elevation - Night View (NTS)
*FIELD SURVEY EXISTING CONDITIONS FOR INSTALLATION
As Noted 89209 R2 Shoppers World
100 Shoppers World Court
Lane Bryant #4793 Charlottesville, VA 22901
A
LL Approval
CSI Approval
Conceptual Artwork
Amanda Otto
Date
03.13.13
Sales
File Location
W
Construction Drawing
Date
Project Manager
Janet Piccione
Revision Note
DATE INITIALS NOTES
03.13.13 ATO Order #, Back Door Vinyl
04.08.13 ATO New Custom Ltr Dim.
This Drawing Last Updated on:
' . 1 ' ' 04.08.13
CSI REQUIRES THAT DISCONNECT SWITCH
BE LOCATED AT POINT OF POWER SUPPLY
UNLESS CODE DICTATES OTHERWISE
ALL SIGN WIRING AND DISCONNECT SWITCH
TO ADHERE TO NEC CODE 600.6
U.L. NOTE
CODES. THIS INCLUDES PROPER GROUNDING
AND BONDING OF SIGN.
THIS SIGN IS INTENDED TO BE INSTALLED IN
ACCORDANCE WITH THE REQUIREMENTSOF
ARTICLE 600 OF THE NATIONAL ELECTRICAL
CODE AND /OR OTHER APPLICABLE LOCAL
WHITE OPAQUE WINDOW VINYL
2 -Commercial ■ (9) .74 So. Ft. ■ N/A
A
A
■9 ■
L
12" AFF
.74 Sq. Ft. WINDOW VINYL DETAIL
Scale: 1 1/2' = 1' - 0"
3M 220 -10 WHITE VINYL COPY LOGO AND WEBSITE APPLIED
2ND SURFACE ON WINDOWS 12" ABOVE FINISHED FLOOR
& CENTERED HORIZONTALLY ON THE WINDOW
WEBSITE FONT. BERTHOLD AKZIENZ GROTESK EXTENDED
As Noted 89209 R2 Shoppers World
100 Shoppers World Court
. _ . .. Lane Bryant #4793 Charlottesville, VA 22901
2nd Surface IRK N/A N/A
Conceptual Artwork
Amanda Otto
Date
03.13.13
Sales
File Location
12" A.F.F
Store Elevation - Day View (NTS)
*FIELD SURVEY EXISTING CONDITIONS FOR INSTALLATION
LL Approval
CSI Approval
IF
Construction Drawing
Date
0
Project Manager
Janet Piccione
Revision Note
DATE INITIALS NOTES
03.13.13 ATO Order #, Back Door Vinyl
04.08.13 ATO New Custom Ltr Dim.
This Drawing Last Updated on:
.. 04.08.13
CSI REQUIRES THAT DISCONNECT SWITCH
BE LOCATED AT POINT OF POWER SUPPLY
UNLESS CODE DICTATES OTHERWISE
ALL SIGN WIRING AND DISCONNECT SWITCH
TO ADHERE TO NEC CODE 600.6
U.L. NOTE
CODES. THIS INCLUDES PROPER GROUNDING
AND BONDING OF SIGN.
THIS SIGN IS INTENDED TO BE INSTALLED IN
ACCORDANCE WITH THE REQUIREMENTSOF
ARTICLE 600 OF THE NATIONAL ELECTRICAL
CODE AND /OR OTHER APPLICABLE LOCAL
16.00"
Back Door Vinyl (Qty: i)
Grade • uare Footag
2 -Commercial I 7—N/'-A— I Black Vi
f1rn111/1r nnnn \ /IAI \/I I A \lr1l IT
A
A
PROTOTYPICAL SERVICE DOOR
3M 220 -12 BLACK VINYL APPLIED
FIRST SURFACE ON THE EXTERIOR OF
WHITE / LIGHT COLORED DOORS
W1
3.88"
1st Surface ■ N/A
As Noted
A
89209 R2 Shoppers World
100 Shoppers World Court
Lane Bryant #4793 Charlottesville, VA 22901
LL Approval
CSI Approval
Conceptual Artwork
Amanda Otto
Date
03.13.13
Sales
File Location
IF
Construction Drawing
Date
0
Project Manager
Fianet Piccione
Revision Note
DATE INITIALS NOTES
03.13.13 ATO Order #, Back Door Vinyl
04.08.13 ATO New Custom Ltr Dim.
This Drawing Last Updated on:
ff . -- 04.08.13
CSI REQUIRES THAT DISCONNECT SWITCH
BE LOCATED AT POINT OF POWER SUPPLY
UNLESS CODE DICTATES OTHERWISE
ALL SIGN WIRING AND DISCONNECT SWITCH
TO ADHERE TO NEC CODE 600.6
U.L. NOTE
CODES. THIS INCLUDES PROPER GROUNDING
AND BONDING OF SIGN.
THIS SIGN IS INTENDED TO BE INSTALLED IN
ACCORDANCE WITH THE REQUIREMENTSOF
ARTICLE 600 OF THE NATIONAL ELECTRICAL
CODE AND /OR OTHER APPLICABLE LOCAL