HomeMy WebLinkAboutSDP201300012 Resolution - Board of Supervisors 2013-04-23pF AL
�IRGII31P+
COUNTY OF ALBEMARLE
Department of Community Development
401 McIntire Road, North Wing
Charlottesville, Virginia 22902 -4596
Phone (434) 296 -5832 Fax (434) 972 -4126
April 23, 2013
Daniel Hines
28 Blackwell Park Lane
Warrenton, Virginia 20186
RE: SDP - 2013 -012- Fifth Street Station- Initial Site Plan
Mr. Hines:
The Agent for the Board of Supervisors hereby grants administrative approval to the above referenced site
plan.
This approval shall be valid for a period of five (5) years from the date of this letter, provided that the
developer submits a final site plan for all or a portion of the site within one (1) year after the date of this
letter as provided in section 32.4.3.1 of Chapter 18 of the Code of the County of Albemarle, and thereafter
diligently pursues approval of the final site plan.
An Erosion and Sediment Control Permit may be issued after the following are received:
1. Approval an Erosion and Sediment Control Plan meeting the requirements of Chapter 17 of the
Code of the County of Albemarle.
2. Approval of a Stormwater Management Plan meeting the requirements of Chapter 17 of the
Code.
3. Approval of all easements for facilities for stormwater management and drainage control.
4. Approval of a mitigation plan for the disturbance of Water Protection Ordinance buffers.
5. Submittal of a tree conservation checklist.
6. The early grading plan shall not contain fill in the floodplain, unless a CLOMR is approved by
FEMA before the grading permit is issued.
7. Stormwater Management, Erosion and Sediment Control, and Mitigation Plan bonds to be posted.
The final site plan will not be considered to have been officially submitted until the following items are
received:
1. A final site plan that satisfies all of the requirements of section 32.6 of Chapter 18 of the Code.
2. A fee of $1,500.
3. Submittal of plans directly to each of the agencies /departments listed below necessary to satisfy
the conditions of approval.
The final site plan will not be approved until the following conditions are met:
The Department of Community Development shall not accept submittal of the final site plan for signature
until tentative approvals for the following conditions have been obtained:
Planning Division Approval of: (5 Copies are required to be submitted for review)
1. A site plan meeting all the requirements of section 32.6 of Chapter 18 of the Code.
2. A landscape plan meeting the requirements of section 32.7.9 of Chapter 18 of the Code, including
a tree conservation checklist.
3. ARB certificate of appropriateness
4. All applicable proffers to be met.
5. [32.5.2 (a)] Tax Map 77 -11E needs to be added to the plans.
6. [32.5.2 (a)] Need to shade back topography on sheet 4, it's difficult to see the owners listed.
7. [32.5.2 (b); Proffers 2 and 3] Provide the percentage of open space. Also, show the greenway trail
and associated grading for the trail.
8. [32.5.2 (c)] On sheet 6 in the legend, the BMP information/symbol doesn't show up. Revise.
9. [32.5.2 (d)] Indicate with shading those areas of the site where existing slopes are critical slopes.
10. [32.5.2 (e)] Label all the existing wooded areas and provide a general description of the type of of
trees (ie deciduous, evergreen, or mixed).
11. [32.5.2 (i); 32.5.2 (n)] Provide the material type and dimensions for the shoulder along Bent
Creek Road.
12. [32.5.2 (i)] Provide a sidewalk from the parking to the bus stop within the park and ride lot.
13. [32.5.2 (n)] Provide the height for all proposed fences.
14. [32.5.2 (n)] What kind of walls are the retaining walls? The width being shown seems to be
inaccurate. If they are block/redi -rock walls, the full width needs to be shown. Also, the limits of
disturbance seem to be inaccurate to construct these walls, revise to show possible full impact.
15. [32.5.2 (n)] Show the proposed concrete ditch along the edge of the wall along Bent Creek
Parkway on the grading plan.
16. [32.5.2 (o)] Show all areas intended to be dedicated or reserved for public use including the
greenway trail and park.
17. [32.5.2 (p)] Provide on a landscape sheet the conservation plan checklist.
18. [32.5.2 (p)] A waiver for the requirement of street trees needs to be provided for the minor
variation in accordance with Section 32.3.5 (b). Staff would like street trees to be provided all
along Bent Creek parkway where possible. This will also be a factor when reviewing the request
in Comment #18. Eliminating the gravel shoulder and putting in an urban section of road will
allow room for street trees.
19. [32.7.9] Show the right of way lines on the landscape plan. Trees shall be located within the right
of way where feasible.
20. [32.7.9] Show the utility easements for all utilities on the landscape plan to ensure that the trees
are outside of the easements.
21. [4.12.16 (e)] Bumper blocks need to be provided wherever curb and gutter is not, unless waived
by the County Engineer.
22. [Proffer #1 -C] Provide a request for a waiver for the street requirements to be a "rural section" in
design for review by staff and the Board of Supervisors.
23. [Proffer #1 -G] See comments from CAT regarding the park and ride lot and transit stops.
Coordinate the location of all transit stops with CAT.
24. From E911: The road name 'BENT CREEK PARKWAY' is approved for this project. An
additional road name would be needed for the interior of the development for addressing needs.
A road name that could be used is 'BENT CREEK PLACE' located through the center of the
development by the round -a -bout for addressing purposes.
Engineering Division Approval of: (2 copies are required to be submitted for review)
1. An Erosion and Sediment Control Plan meeting the requirements of Chapter 17 of the Code of the
County of Albemarle
2. A Stormwater Management Plan meeting the requirements of Chapter 17 of the Code.
3. All easements for facilities for stormwater management and drainage control.
4. A mitigation plan for the disturbance of Water Protection Ordinance buffers.
5. Road plans.
A. Application Information
1) Please identify special use permit number (SP2012- 00029) in "floodplain special use
permit" on sheet 1.
2) Please provide US Army Corps approval for "wetlands to be demolished" and fill in
flood plain per 3/13/2013 #4 condition of Board of Supervisors approval of SP2012-
00029.
B. Existing Conditions Information
1) Please provide date and source of topographic information. All topography
should be at least visually field verified by the designer with the last year.
2) Please provide a benchmark location, elevation, and datum for topography. An
existing utility or other known position will suffice.
3) Please darken the labels and/or indicate the the 100' (beyond stream banks or
edge of wetland) Water Protection Ordinance buffer limits for Moore's Creek, Biscuit
Run, and all non -tidal wetlands on sheets 5A — 5J. These limits inform the buffer
incursion area and needed mitigation area (which is part of WPO plans) and also need to
be included with an approved initial site plan.
4) Please indicate dimensions and recorded deed book and page number for all
existing easements including:
a. an existing gas line and overhead utilities which appear on sheet 5C
b. an existing road which appears on sheet 5D
c. existing overhead utilities, a road, and a water line which appear on sheet
5E
d. existing road which appears on sheet 5F
e. existing water line which appears on sheet 5G
5) Please indicate all critical slopes (> 25% slope) with grey shading for clarity.
C. Proposed Plan View Information
1) Please indicate guardrail with VDOT designations for all retaining walls next to
parking or travelways [18- 32.7.2].
2) Please expand legend to include symbol for a proposed easement (appears to be a
circle) and abbreviations for proposed easement types (apparently including: drainage,
sanitary sewer, gas, water, access, stormwater managemement, and possibly
intersection and/or entrance sight distance). Please include a callout for each proposed
easement on each sheet (i.e. if a proposed easement area appears on three sheets, please
label it on each of the three sheets).
3) Please expand drainage easements to include erosion control riprap at pipe outlets
(appears to be riprap outside of the proposed easement area on sheet 9A).
4) Please clearly indicate by station the limits of proposed public right of way and access
easement for privately maintained sections of Bent Creek Pkwy proposed.
5) Please indicate intersection and entrance sight distance lines in plan view at minimum.
Intersection and/or entrance sight distance easements may be needed.
6) Trees are prohibited in drainage easements. It appears one "SJR" tree is proposed in
conflict with a drainage easement on sheet I IF. It appears one "TCG" and one "QPH"
tree are proposed in conflict on sheet I IG. Please revise proposed drainage or
landscape plan to avoid these conflicts.
7) Commercial entrances appear to be proposed on sheets 8C, 81), 8E, 8G, and 8I. Please
provide VDOT designation type for these entrances (e.g. PE -1, CG -9a, etc.).
8) Please label proposed radius for NW corner of entrance proposed on sheet 8G.
9) Turn lanes and tapers for intersection of Bent Creek Pwky and Avon St appear to be
proposed on sheet 9J. Please label the widths and taper rates proposed.
10) Please include by note or leader description the type of curbing proposed on all parking
areas with VDOT designations (e.g. CG -2, CG -6).
11) Please label edges of proposed paving in areas proposed which appear to not have curb
adjacent (see sheets 8E and 8I).
12) Please provide a unique label for each proposed drainage structure and pipe for
calculation reference.
13) Please provide spot elevations around proposed dumpsters to ensure they are not in low
spots for drainage.
D. Proposed Plan Detail Information
1) Please provide source of information for proposed traffic volumes (a previously
approved plan or ITE Trip Generation Handbook or equivalent are acceptable).
Please adequately address the following comments for final site plan approval:
E. Application Information
1) Owner is required to provide a completed copy of the standard stormwater
maintenance agreement and fee for recordation for any stormwater management
facilities (could reference an existing agreement with a comparison of proposed vs
previously approved impervious surface).
2) Prior to final site plan approval, a separate set of Water Protection Ordinance plans
must be approved including: stormwater management plan and erosion and sediment
control plan (could reference an existing plan with a comparison of proposed vs
previously approved impervious surface for SWM).
3) Please provide a separate set of road plans for proposed public and private sections of
Bent Creek Parkway. Please submit the subdivision plat application available here:
< hltp:// www. albemarle .org/upload/imaizes /forms_center /departments /Community De
velopment/ forms / applications /Subdivision_ Plat_Preliminga & Clip cklist. &>
and include "PRIVATE STREET FEES" ($400 fee) for a review of proposed road
plans. Please note: all streets and alleys proposed in the development area require curb
and gutter, a planting strip, and sidewalks [14- 410.H].
4
4) Prior to final site plan approval:
water protection ordinance — erosion and sediment control and
stormwater management
subdivision - water and sewer and subdivision - road
bonds must be calculated by the county (water and sewer bonds are calculated by
ACSA) and paid by owner after receipt of a Bond Request Form from owner
(could reference an existing SWM bond or county accepted SWM facility with a
comparison of proposed vs previously approved impervious surface).
F. Plan Detail Information
1) Please propose a pavement design on typical sections for each public and private road
proposed which supports proposed traffic loadings per 2009 VDOT Pavement Design
Guide for Subdivision and Secondary Roads in Virginia or equivalent.
2) Please include sidewalk and dumpster pad details meeting requirements per 14 -422 and
Albemarle County Design Standards Manual.
3) Please provide typical retaining wall details referenced from the plan. A typical
manufacturers drawing for segmental block walls, or VDOT reference, is acceptable,
with any applicable safety hand rails or guardrail shown on the detail.
4) Please provide details for any pipes or drainage structures through or under walls,
showing endwalls, casings, or structureal measures to bridge pipes or structures (e.g.
proposed pipe shown crossing proposed wall on sheet 9C).
G. Drainage Profiles
1) Please include drainage profiles for all proposed pipes and ditches.
H. Drainage Computations
1) Please include drainage computations including for proposed trench drain outlet.
6. Please provide a forest stewardship plan in accordance with proffer #5.
7. Please indicate location of greenway dedication easement per proffer #2.
8. Please indicate proposed easement for any proposed off -site grading including grading adjacent to
I -64 right of way shown on sheet 9F.
9. Please provide details for proposed transit stop for final site plan approval per proffer #1G.
Albemarle County Architectural Review Board Approval of a Certificate of Appropriateness. (8
Copies are required to be submitted for review)
Regarding requirements to satisfy the design guidelines as per 30.6.4(2), (3) and (5):
1. Revise the massing of the Wegman's and Major Tenant A buildings to reflect the traditional
architecture of the area. Break up the mass into components whose scale reflects that of the traditional
architecture of the area.
2. Revise the Wegman's and Major Tenant A buildings to reduce the visual effect from the Entrance
Corridors.
3. Revise the massing of Wegman's and Major Tenant A buildings to a scale that does not overpower
the natural setting.
4. Eliminate the visual effect of the loading /service /refuse areas from the Entrance Corridors.
5. Revise the interface between the site layout and the existing surrounding topography which is visible
from the Entrance Corridors to better transition between the proposed shopping terrace and the
existing grades, using a combination of planting, material, terracing, and other strategies to more
effectively correspond to the guidelines.
6. Revise the plan to show consistent and adequate planting area free of utilities and easements along the
I64 side of the site, to a width sufficient to mitigate visual impact from the Entrance Corridor.
7. Provide planting area for trees along Bent Creek Parkway from Avon Street at least to the intersection
of Bent Creek Parkway with the first turnoff for the Major Tenant A building, consistent with the
approved landfill work plan.
Regarding recommended conditions of initial site plan approval:
1. Approval of a Certificate of Appropriateness is required prior to final site plan approval.
Regarding conditions to be satisfied prior to issuance of a grading permit:
1. Provide a conservation plan checklist. Show all the checklist items on the plan.
Albemarle Countv Fire & Rescue ADDroval. (1 CODV is required to be submitted for review
1. Where new water mains are extended along streets where hydrants are not needed for protection
of structures or similar fire problems, fire hydrants shall be provided at spacing not to exceed
1,000 feet to provide for transportation hazards. Please install hydrants on Bent Creek Parkway at
1,000 foot intervals.
2. Fire hydrants shall be provided on all public streets and fire apparatus access roads. The hydrants
shall have an average spacing of 500 feet. Please adjust hydrants currently shown on the
submitted plans accordingly.
3. Fire Department Connections shall be shown on the site plan. The fire department connections
shall be located on the address side of the structure. The fire department connections shall be
located within 50 feet of a fire hydrant and preferably away from the structure to prevent blocking
traffic when hose lines are in use during firefighting operations.
4. Fire lanes will be required around Wegman's, Major Tenant A and the parking lot of Tenant F.
Please call the Fire Marshal's Office at 434 - 296 -5833 to discuss the exact locations to be marked
and signed.
5. The minimum turning radius on the travel ways throughout the property shall be 25' for roads that
are 20 -32' wide. This will not apply to the aisles serving the parking spaces only those streets or
lanes that provide ingress and egress throughout the property. Please contact the Fire Marshal's
office at 434 - 296 -5833 to discuss the areas that need addressed on the plans.
6. Provide building construction types so that the required fire flow can be determined. Once
calculated documentation must be provided to the Fire Marshal's Office that the required fire flow
is available throughout the site.
7. These buildings will be required to have Knox Boxes for each tenant space. Contact the Fire
Marshal's office for ordering information and installation location approval.
Albemarle County Service Authority Approval. (3 Copies are required to be submitted for review)
1. Water main river crossing.
a. Will require gate valve between county and city ownership.
b. Will require testing taps on each side of crossing.
2. Water main sizes within the development.
3. 12" water main connection point.
4. Sanitary Sewer Connection
5. RWSA Capacity Certification
Virginia Department of Transportation Approval. (1 Copy is required to be submitted for review)
Typical Section
1. Shoulder should meet VDOT Road Design Manual GS -7 standards.
6
General
2. A paved shoulder should be used rather than a gravel shoulder to prevent stones from
obstructing bike lane.
3. VDOT suggests using curb and gutter instead of shoulder along the road for permanent typical
section.
4. Geometry should allow for a 16ft median for potential expansion to 4 -lane road in the future.
5. Raised medians should be used rather than painted medians.
6. Road geometry cannot be accurately assessed due to through lanes not meeting up with center
line. Provide a center line for currently proposed section of road.
7. Show curb ramps on sidewalk.
8. Entrances from Bent Creek Road to parking and retail areas need to meet minimum throat
length standards.
9. Entrances should be consolidated at the new intersection of Bent Creek Road and Avon Street.
10. Permits will be required for grading on I -64. Applicants should be in touch with necessary
parties as soon as possible.
11. Road and drainage plans need to be provided and reviewed.
Rivanna Water and Sewer Authority (RWSA) Approval. (1 Copy is required to be submitted for
review
General Plan Comments:
1. RWSA previously issued a flow acceptance for this project; however, the flow capacity
certification has expired. Prior to final site plan approval, a new request should be sent to RWSA
for acceptance of sewage flows with updated flow numbers.
2. The RWSA Moores Creek Interceptor (located along the north bank of Moores Creek) should be
surveyed and shown on all plan sheets.
3. Label RWSA interceptor with ownership, size, and material (e.g. `RWSA 30" RCP Sanitary
Sewer').
4. Correctly show and label RWSA sanitary sewer easements with deed book and page numbers.
Utility Plan (Sheets I OA -J):
1. The Utility Plan shows several stormwater outfalls to Moores Creek for this project. The RWSA
Moores Creek Interceptor is located adjacent to the north creek bank along the entire project site,
and erosion has been observed since the interceptor was constructed in 1974. RWSA is concerned
that the stormwater design shown on the plans may exacerbate existing erosion conditions and as
a result, undermine the stability of the sewer line. Of particular concern are structures STM D 1
(sheet l OC) and STM D9 (sheet 101)), both of which may substantially alter stream flow patterns.
Please provide documentation on how you intend to mitigate velocity and channel modifications
caused by outfalls which would cause erosion on the north side of the creek.
2. Sheets 9A and 9E show connections to both City of Charlottesville and ACSA water lines.
RWSA is currently developing a wholesale master metering program to monitor urban water
usage by the City and the County. Further details on the program will be forthcoming; however it
is likely that a meter and vault to be owned and operated by RWSA will be required at the
interconnection. Exact details may be coordinated through future site plan work.
Landscape Plan (Sheet I IA):
1. On sheet I IA, portions of the "tree conservation" areas intersect the existing RWSA sewer line
easement. Please be aware that RWSA routinely performs maintenance clearing of its easements,
and as such, trees in this area will be removed.
Proffers:
1. Proffer #7 describes the contractor's requirements to complete erosion and buffer projects for
Moore's Creek in the areas designated in the attached Exhibit B. RWSA would like a copy of the
scope and schedule of these projects to determine their impacts on the existing Moores Creek
Interceptor.
Charlottesville Area Transit (CAT) Approval (1 Copy is required to be submitted for review)
7
1. Option 1:
a. We believe this option would better serve the shopping center and allow passengers
better access to the locations. However, it does entail going through the facility rather
than going around it. Questions we had were if the parking spaces that are marked with
squares can be converted into bus pull outs /stops. Additionally, we were not sure if the
circle is capable of handling a 35 foot bus.
2. Option 2:
a. There are 2 locations I see possible for bus stops. The western stop would be located and
what seems to be a pavilion/entrance. However, because the location is right after a turn,
it might have to be pushed further north. The eastern stop would have no issues if a cut
out can be built into the median there. Additionally, stops will have to be put on the
opposite of each stop to serve in both direction.
Both options include driving by the park and ride. It is ideal not to go into the park and ride lot
and have stops on either side of the main street. However, if that's not possible, going into the
park and ride lot can be considered.
If you have any questions about these conditions or the submittal requirements please feel free to contact
me at Extension 3004, myaniglos @albemarle.org.
Sincerely,
Megan Yaniglos
Senior Planner