HomeMy WebLinkAboutWPO201300064 Review Comments WPO VSMP 2014-10-29To: Nat Perkins Subject: RRM_NewDev_v.2.8_2011specs.xlsm Attachments: RPM _NewDev_v.2.8_2011specs.xlsm; Albemarle_SWPPP _ template_2Oct2014.doc Nat, I ran the numbers for the VRRM spread sheet and it appears the credits for the Filterra was set on the old numbers. The State only gives Filterra 50% removal rate now. If this site had been grandfathered then the number would have been 740 http:// www. vwrrc. vt.edu /swc /ProprietaryBMPs.html I ran the numbers and you've shown that 80% is captured so the owner could buy the remaining credits if they wanted. See attached VRRM spread sheet. As for the rest of the review: 1. The owner is the "operator" until they transfer the "operator" status to a contractor or other person willing to take on that responsibility. 2. VSMP plan cannot be approved without the SWPPP and the PPP plans filled out and signed by the owner. Glenn has boiler plates for these that he'd like everyone to use so we have some regularity in our reviews. See attached. 3. Could you put the paved entrance detail on the plans? The WPO inspectors insist that the paved entrance detail is shown, they want the power to work with the contractor as to whether or not they are required to use the paved entrance vs. the stone entrance. Here's a link Glenn has produced to help with plan preparations. http:// albemarleengineer.blogspot.com / 2014 /10 /vpdes- cgp- vsmp- vrrm -bmp- swppp- reference.html Thanks, Max