HomeMy WebLinkAboutARB201300038 Legacy Document 2014-01-02Sign Diagrams
Sign Dimensions
Sign
Height
Distance to property line
or edge of right -of -way
Sign Height =
Sign Dimensions =
Pole- Mounted Sign — Diagram 1
(Generally not acceptable in the ECS)
AL I
Sign
Height Sign Dimensions
Building Frontage
Building Frontage =
Sign Height =
Sign Dimensions =
Wall Sign — Diagram 3
Sign 2 Height =
Sign 2 Dimensions =
Sign 3 Height =
Sign 3 Dimensions =
Sign Dimensions
Sign
Height
F 10
Distance to property line
or edge of right -of -way
Sign Height =
Sign Dimensions =
Monument Sign — Diagram 2
If multiple wall signs are proposed, list dimensions here:
Sign 4 Height =
Sign 4 Dimensions =
Sign 5 Height =
Sign 5 Dimensions =
Sign Diagrams revised 7/2009 — 1
16"
RACEWAY RUNNING FULL LENGTH OF SIGN
PAINT TO MATCH WALL FASCIA AND FIT IN WALL INLET SCAL.E:1/2, =1'O"
LED. BACK-LIT CHANNEL LETTERS WITH RACEWAY MOUNTED AT FRONT OF STORE
MOUNTING INSTRUCTIONS: INSTALL FLUSH MOUNTED ON TO WALL WITH REMOTE LOW VOLTAGE TRANSFORMERS, USING UL LISTED SPLICED BOXES &
UL LISTED1 /2" FLEX ALUMINUM CONDUIT. INSTALL ALL WIRING AS PER NEC CODE, CONNECT TO EXIST 110 VOLT RECEPTACLE BOX.
TOTAL AMPS: 15 AMPS
SPEC
MATERIAL DESCRIPTION
LOGO HEIGHT
.040 ALUMINUM 24" HEIGHT FOR "LOGO" PAINT TO MATCH COLORS FROM CUSTOMER
ALL CHANNEL LETTERS
.063 ALUMINUM 16" HEIGHT PAINT TO MATCH LOGO COLOR
BACKNG
1/4" CLEAR LEXAN FOR REVERSE/HALO CHANNEL NEON
RETURNS
.063 ALUMINUM 4" SIDE RETURN PAINT TO MATCH LOGO COLORS
RACEWAY MOUNTING FLAT AGAINST WALL FASCIA USING 1 "1/2 SPACERS & 5" BOLTS /EXPANSION SHIELDS (ALL TO BE NON - CORROSIVE)
FACES
ALL .063 ALUMINUM CHANNEL LETTERS PAINT TO MATCH COLORS OF LOGO (AS ABOVE)
ILLUMINATED
LED .FORMULA CHANNEL #4 WHITE LED„ TWO ROWS MINIMUM
TRANSFORMERS
SIGN ILLUMINATED BY TWO 30 ma. (DC- 12,volts EACH) LOW VOLTAGE TRANSFORMERS WITH SMART GROUNDED & SERVICE SWITCH
DRAIN HOLES
TWO DRAIN HOLES AT BOTTOM OF EACH LETTER
UL
LABELED
ALL SECONDARY WIRING TO BE CONCEALED WITH LIQUID TIGHT GREENFIELD
SIGN DIMENSIONS ARE: 24" X 12'0"
STORE FRONT IS 160" IN LENGTH
ALL PENETRATIONS THRU FASCIA ARE TO BE SEALED TO A WATER TIGHT CONDITION WITH ALL WEATHERPROOF SILICONE
Sign to be installed with the requirements of Article 600 of the NEC, this includes proper grounding and bonding of the sign UL.
TYPICAL L.E.D. FLUSH MOUNT (with 1" inch spacers)
REVERSED CHANNEL LETTER SECTION DETAIL
4' SIDE RETURN
REVERSED CHANNEL LETTER
L.E.D. UNITS
WIRE CONNECTOR
GROMMET
PENETRATIONS SEALED
WITH SILICONE
.067 ALL ALUMINUM
REVERSED LETTER
1!4" CLEAR LEXAN
BACKING
718" X 5" ALL THREAD
BOLTSfANCHORS
WITH V SPACERS
SCALE T'5'0"
LED. CHANNEL LETTERS BACK -LIT TO BE INSTALLED AT 9985 SOWDER VILLAGE SQUARE, MANASSAS, VA.
DESCRIPTION OF WORK:
MANUFACTURE(1)ONE SET OF CHANNEL LETTERS INTERNALLY LIGHTED WITH BACK -LIT AS SHOWN ON DRAWING
MATERIALS:
ALL LETTERS AND SIGN BOX ARE TO BE CONSTRUCTED OF .063 ALUMINUM WITH 4 "DEEP ALL BLACK SIDE RETURN -
CHANNEL LETTERS ILLUMINATED BY:
AN INTERNAL SOURCE OF WHITE LED. FORMULA CHANNEL #4 POWERED BY 30 MA / DC -12 VOLTS REMOTE TRANSFORMER
(SMART PKA2NG -1 TYPE. WITH SECONDARY GROUND FAULT PROTECTION) UL. #2161 LISTED WITH NEC COMPLIANT.
TRANSFORMER BOX COVER
TRANSFORMER BOX
TRANSFORMER
110 VOLT SERVICE
MOUNTING SCREWS
LOW VOLTAGE WIRE
CONNECTOR
SLEEVE TO
RUN THROUGH WALL
EXISTED WALL FACADE
INSTALLATION:
FLUSH MOUNTED WITH COMBINATION OF 1 "'/2 SPACERS (GAP FOR HALO LIT) TO WALL FACADE OF STORE FRONT (AS PER PHOTO PICTURE)
PK GLASS HOUSING USING THRU WALL FOR ALL GTO TO ELECTRODES CONNECTIONS.
ALL WIRING, TRANSFORMERS CONCEALED & SECURED BEHIND WALL FACADE - ELECTRICAL: RUN TO SIGN LOCATION BY ONE 20 AMP -120 VOLT CIRCUIT (EXISTED)
NO EXPOSED FASTENERS, NO SEAM IN ALL LETTER FACES, LETTERFORMS AND BOX WHICH ARE VISIBLE FROM GROUND. ALL PENETRATIONS ARE TO BE SEAL WITH OUT -DOOR CLEAR SILLICONE
SIGN DIMENSIONS ARE: 24" TALL X 15'0" WIDE X 4" DEEP ( +1 "1/2 GAP FOR HALO PURPOSE) - STORE FRONT IS 21' -0" IN LENGTH
ALL PENETRATIONS THRU FASCIA ARE TO BE SEALED TO A WATER TIGHT CONDITION WITH ALL WEATHERPROOF SILICONE
Sign to be installed with the requirements of Article 600 of the NEC, this includes proper grounding and bonding of the sign UL.