September 3, 2014
Dustin Greene
Dominion Engineering
172 South Pantops Drive
Charlottesville, VA 22911
RE: SUB201400110 Whittington Phase B- Preliminary Plat
Mr. Greene:
The Agent for the Board of Supervisors hereby grants administrative approval to the above referenced
subdivision plat.
This approval shall be valid for a period of five (5) years from the date of this letter, provided that the
developer submits a final subdivision plat for all or a portion of the site within one (1) year after the date
of this letter as provided in 14 -226 of the Subdivision Ordinance of the County Code, and thereafter
diligently pursues approval of the final subdivision plat.
An Erosion and Sediment Control Permit may be issued after the following approvals are received:
1. Approval an Erosion and Sediment Control Plan meeting the requirements of Chapter 17 of the
Code of the County of Albemarle.
2. Approval of a Stormwater Management Plan meeting the requirements of Chapter 17 of the
Code.
3. Approval of all easements for facilities for stormwater management and drainage control.
4. Approval of a mitigation plan for the disturbance of Water Protection Ordinance buffers.
5. Submittal of a tree conservation checklist.
The final subdivision plat will not be considered to have been officially submitted until the following
items are received:
1. A final subdivision plat that satisfies all of the requirements of 14 -226 of the Subdivision
Ordinance.
2. A fee of $1,230.
Please submit eight (8) copies of the subdivision plat to the Community Development Department. The
assigned Lead Reviewer will then distribute the plans to all reviewing agencies. Once you receive the
first set of comments on the final subdivision plat, please work with each reviewer individually to
satisfy their requirements.
The final subdivision plat will not be approved until the following conditions are met:
The Department of Community Development shall not accept submittal of the final subdivision plat for
signature until tentative approvals for the following conditions have been obtained:
Planning Division Approval of (2 copies):
1. A plat meeting all the requirements for final subdivision plats per the subdivision ordinance.
2. [14- 302(A)3] Existing or platted streets. Provide the right -of -way width of State Route 631.
3. [14- 302(A)4 &5] Private & public easements. Label all new easements as 'proposed'.
4. [14- 302(A)9] Building sites on proposed lots. Building sites are required to be the size of the
anticipated dwelling footprint plus the area of setbacks /yards. While critical slope disturbance
was addressed in the proffers for ZMA200600011, several of the proposed lots are significantly
impacted by stream buffer (lots 5, 13, 23, 27, 28, 29 & 76 in particular). Adequate building sites
must be provided outside of the stream buffer. Provide a "typical" minimum building site
diagram with the resultant required square footage (as indicated above) and show that lots
limited by stream buffer in fact provide this minimum required building site.
5. [14- 302(A)11] Instrument creating property proposed for subdivision. Provide the most recent
instrument in addition to the information shown on sheet 2.
6. [14- 302(B)5] Zoning classification. Add Entrance Corridor (EC) to the zoning note.
7. [14- 302(8)8 & 18- 19.9.1] Setbacks. The plat indicates that lots 30 -36 will have a 35' rear setback
as they are adjacent to RA zoning. Lot 87 also adjoins RA property; please add lot 87 to the list
of lots that will have a 35' rear setback.
8. [14- 302(B)10] Stream buffers. Add the following note: "The stream buffers shown hereon shall
be managed in accordance with the Albemarle County Water Protection Ordinance."
9. [ZMA200600011 Proffer 1] Prior to Final Plat approval, Phase B must be added to the
Covenants and Restrictions of the homeowner's association (assuming CCRs were created for
Phase A). This document should include maintenance responsibility for all open space and other
privately owned improvements, and must be reviewed and approved by the County Attorney's
Office.
10. [ZMA200600011 Proffer 2] Each lot is required to be a minimum of 40,000 square feet. Provide
the square footage calculations for each lot rather than the acreages.
11. [ZMA200600011 Proffer 4] Prior to Final Plat approval, an overlot grading plan must be
submitted that meets all requirements listed in Proffer 4 for Engineering review and approval.
This review may result in a reduction of the number of approvable lots.
12. [ZMA200600011 Proffer 7] The Application Plan approved with ZMA200600011 shows a picnic
shelter within Open Space J and two trails leading from Open Space J and connecting to the
larger trail system within the subdivision. One of the trails goes through Open Space H
connecting to the trail system in Open Space F, and the other goes between lots on Street B and
Kendra Street to connect to the trail system in Open Space E. These amenities should be
provided as shown on the Application Plan; show the trail system as indicated and note that the
picnic shelter will be provided. Prior to Final Plat approval, a performance bond will likely be
required for the picnic shelter.
13. [ZMA200600011 Proffer 8] The 25' screening and landscaping easement must be shown and
labeled on the plat. A landscaping plan that meets current regulations for screening must be
provided, either with the road or WPO plans or as a separate submittal. Maintenance and
responsibility of the screening within the easement should be addressed in the Covenants and
Restrictions mentioned above. A note alerting affected owners to this easement restriction on
their property shall be stated on the Final Plat.
14. [ZMA200600011 Proffer 9] Trail locations and construction details should be provided on the
Road and /or WPO Plans.
15. [ZMA200600011 Application Plan] The lot numbers within the subdivision do not match the lot
numbering provided on the application plan. To eliminate confusion, please revise the lot
numbers on this plat to match the application plan.
16. [Comment] Road Plans and WPO application must be approved, all required improvements
must be built or bonded, and all required Deeds and Declarations must be reviewed and
approved prior to Final Plat approval.
Please contact Ellie Ray at 296 -5832 if you have questions or require additional information.
Engineering Division Approval of (1 copy of site plan: WPO plan number stated in application):
1. VDOT approval for road geometry.
2. Please label the contour elevations per survey information or GIS.
3. Walking path Bridges should be shown.
4. Slope of walking path located at the end of Kendra Street appears too steep to traverse.
5. Access roads for storm water maintenance facilities should be shown on the initial plat, but will
be required on the final Plat.
6. VSMP requirements will adequately addressed prior to Final Plat Approval.
7. "No Parking" signs may be required.
8. Please delineate the areas of "Low Maintenance Vegetation" as required by Proffer 4d on the
plan.
9. Proffer 4f does not appear adequately addressed.
10. Proffer 4g does not appear adequately addressed.
11. Proffer 4h does not appear adequately addressed.
Please contact Max Greene at 296 -5832 if you have questions or require additional information.
ACSA approval to include (1 copy to County, 3 copies to ACSA):
The applicant should submit 3 copies of construction drawings along with water and sewer data sheets
to the ACSA (Attn: Jeremy Lynn, PE). The ACSA has determined certain items that will be evaluated
during the construction review that the applicant should be aware of:
1. Final water and sewer plans required for ACSA construction approval.
2. Sheet PSP5: ACSA will require a connection to the existing watermain near road St. 26 +50.
3. Sheet PSP5: Waterline relocation plan required at road crossing due to the addition of fill
material.
4. Sheet PSP8: Waterline relocation plan required at road crossing due to the addition of fill
material.
5. Sheet SPS8: Clearly show Phase A existing infrastructure versus phase B proposed infrastructure.
6. Sheet SPS9: Clearly show Phase A existing infrastructure versus phase B proposed infrastructure.
Please contact Alex Morrison at 977 -4511 ext 116 if you have questions or require additional
information.
E911 approval to include (1 copy):
1. Before final approval can be given the applicant should contact this office with a list of three (3)
names for 'Street A', 'Street B', and 'Street C' for approval.
Please contact Andrew Slack at 296 -5832 if you have questions or require additional information.
Fire & Rescue approval to include (1 copy):
1. Cul -da -sac's shall be 96 ft FC /FC.
2. Fire Flow test required prior to final approval.
Please contact Robbie Gilmer at 296 -5833 if you have questions or require additional information.
VDOT approval to include (1 copy):
1. Proposed pavement design will need to be verified by pavement design calculations that will
need to be submitted with the road plan.
2. Justification for the reduction of the minimum pavement width of 24' to 20' should be added to
the typical section for streets "A ", "B ", and "C ". In addition, the typical section for these streets
should be noted as "No Parking" on the streets.
3. The typical section for Kendra Street should be noted as "No Parking ".
4. Sheet number 6 of 14 shows storm sewer located within the roadside ditches. What is the
purpose of including storm sewer in these areas?
5. On sheet number 11 of 14, is the terminus of Kendra Street shown proposed to be a temporary
or permanent turnaround? The preferred turnaround at this location would be a cul -de -sac.
The "branch- type" turnaround shown does not appear to have an adequate length or radii.
6. Per Appendix B(1) of the Road Design Manual, cul -de -sacs with unpaved centers should be
considered one -away and designed in accordance with Table 3 of Appendix B(1). Refer to page
B(1) -24 of the Road Design Manual.
7. On sheet 13 of 14, Route 631 does not appear to be drawn accurately based on the contours
provided. The edge of pavement of Route 631 should be field verified and reflected on the
preliminary plat.
8. 1 question the availability of adequate intersection sight distance at the intersection of street "C"
and Route 631. Sight lines should be provided at each intersection, and sight line profiles should
be provided at locations with questionable sight distance such as the intersection of street "C"
and Route 631. For 45 mph, the minimum intersection sight distance required is 500 feet.
9. The alignments and locations of the proposed streets may need to be adjusted as the road plans
are prepared and reviewed.
Please contact Troy Austin at 422 -9373 if you have questions or require additional information.
If you have any questions about these conditions or the submittal requirements please feel free to
contact me at Extension 3432, eray @albemarle.org.
Sincerely,
6'. 26t
Ellie C. Ray, PLA
Senior Planner