304 Series'"Canopy Luminaire - Petroleum Symmetric - Recessed Mount for
Product Description
Luminaire housing is constructed from rugged die cast aluminum components.
LED driver is mounted in a sealed weathertight center chamber that allows for
access from below the fixture. Luminaire housing incorporates integral high
performance heatsink fins specifically designed for LED canopy application.
Luminaire mounts directly to the canopy deck and is secured in place with
die -cast aluminum trim frame. Luminaire housing is provided with factory
applied foam gasket and provides for a watertight seal between luminaire
housing and canopy deck. Integral junction box allows ease of installation
without need to open luminaire. Suitable for use in single skin canopies with
16" (406 mm) wide panels. See 227 Series for canopies using 12" (305mm)
deck sections. Designed for canopies of 19 - 22 gauge (maximum 0.040"
[1 mm] thickness).
Performance Summary
Utilizes BetaLED° Technology
Patented NanoOptic' Product Technology
Made in the U.S.A. of U.S. and imported parts
CRI: Minimum 70 CRI
CCT: 5700K (+ / - 500K) Standard, 4000K ( +/ 300K)
Limited Warranty': 10 years on luminaire / 10 years on Colorfast DeltaGuard° finish
Ordering Information
Example: CAN- 304- PS- RS- 04- E- UL -SV- 350- OPTIONS
O
im)
56mm)
8.7"
(220mm)
9.6"
(2441 mm)
W
rm
�2 0 7mm)
ika
CAN -304
PS
RS
x 24" (610mm) x 3" (76mm); (48"
E
above luminaire.
®Beta LED
TECHNOLOGY
Product
CAN -304
•.
PS
RS
04
E
UL
•.
WH
700'
•.
40K 4000K Color Temperature
Petroleum
Recessed
06
Universal
White
700mA
- Color temperature per luminaire
Symmetric
Single
120 -277V
(Standard)
525
DIM 0 -10V Dimming
Skin
UH
Sv
525mA
Control by others
Universal
Silver
350
Refer to dimming spec sheet for availability and
347 -480V
BK
35OmA
additional information
Black
Can't exceed specified drive current
BZ
F Fuse
Bronze
When code dictates fusing use time delay fuse
PB
Not available with all multi -level options. Refer to
Platinum
multi -level spec sheet for availability and
Bronze
additional information
ML Multi -Level
- Refer to multi -level spec sheet for availability and
additional information
* See www.cree.com /lighting /products /warranty for warranty terms.
Requires marked spacing 48" (1,219mm)
x 24" (610mm) x 3" (76mm); (48"
[1,219mm] luminaire to luminaire, 24" [610mm] luminaire to side wall, 6" [152mm]
above luminaire.
®Beta LED
TECHNOLOGY
C u` US
Amth� NNW
Rev. Date: 06/26/13 _ `-
— — — —
� ■ `�� BOO
www.cree.com /lighting T (800) 236 -6800 F (262) 504 -5415
CAN - 304 -PS -RS
Product Specifications
CONSTRUCTION & MATERIALS
• Luminaire housing is constructed from rugged die cast aluminum
components
• LED driver is mounted in a sealed weathertight center chamber that
allows for access from below the luminaire
• Incorporates integral high performance heat sink fins specifically
designed for LED canopy applications
• Provided with factory applied foam gasket and provides for a watertight
seal between luminaire housing and canopy deck
• Mounts directly to the canopy deck and is secured in place with a die cast
aluminum trim frame
• Integral junction box allows ease of installation without need to open
luminaire
• Suitable for use in single skin canopies with 16" (406mm) wide panels
• Designed for canopies of 19 -22 gauge (maximum 0.040" [1mm]
thickness)
• See 227 Series canopies for canopies using 12" (305mm) deck sections
• Exclusive Colorfast DeltaGuard° finish features an E -Coat epoxy primer
with an ultra - durable powder topcoat, providing excellent resistance to
corrosion, ultraviolet degradation and abrasion. Standard is white. Bronze,
black, silver, and platinum bronze are also available
ELECTRICAL SYSTEM
• Input Voltage: 120 -277V or 347 -480V, 50 / 60Hz, Class 1 drivers
• Power Factor: > 0.9 at full load
• Total Harmonic Distortion: < 20% at full load
• Integral weathertight electrical box with terminal strips (1213a -20l3a) for
easy power hookup
• Integral 10kV surge suppression protection standard
• To address inrush current, slow blow fuse or type C / D breaker should
be used
REGULATORY & VOLUNTARY QUALIFICATIONS
• cULus Listed
• Suitable for wet locations
• Enclosure rated IP66 per IEC 60529
• Consult factory for CE Certified products
• 10kV surge suppression protection tested in accordance with IEEE / ANSI
C62.41.2
• Luminaire and finish endurance tested to withstand 5,000 hours of
elevated ambient salt fog conditions as defined in ASTM Standard B 117
• Pending product qualification on the DesignLights Consortium ( "DLC ")
Qualified Products List ("QPL") when ordered with PS or SL optics
• RoHS Compliant
• Meets Buy American requirements within ARRA
Lumen Output, Electrical, and Lumen Maintenance Data
Photometry
All published luminaire photometric testing performed to IESNA LM -79 -08
standards by Independent Testing Laboratories, a NVLAP certified laboratory.
ITL Test Report #: 76940
CA N- 304 -PS -* *- 06 -E -U L- 700 -40 K
Initial Delivered Lumens: 13,581
CAN - 304 -PS * *- 06 -E -UL- 700 -40K
Mounting Height: 15'(4.6m)
Initial Delivered Lumens: 13,190
Initial FC at grade
IES Files
To obtain an IES file specific to your project consult:
http: / /www.cree.com /I ig hti ng /tools- and - support /exterior -i es- configuration -tool
' Actual production yield may vary between -4 and +10% of initial delivered lumens.
*" For more information on the IFS BUG (Backlight - Uplight- Glare) Rating visit www. iesna. org/ PDF/ Frratas/ TM- 15- 1]BugRatingsAddendum.pdf.
* ** For recommended lumen maintenance factor data see TD -13. Calculated L70 based on 6,000 hours LM -80 -08 testing: > 150,000 hours.
© 2013 Cree, Inc. All rights reserved. For informational purposes only. Content is subject to change. See
www.cree.com /patents for patents that cover these products. Cree ®, the Cree logo, BetaLED ®, NanoOptic®
and Colorfast DeltaGuard® are registered trademarks, and the BetaLED Technology logo and 304 Series'" are
trademarks of Cree, Inc.
www.cree.com /lighting T (800) 236 -6800 F (262) 504 -5415
Now
_ WW -_
■L�i
■►
ill■
■_ ■dill■
.
CAN - 304 -PS * *- 06 -E -UL- 700 -40K
Mounting Height: 15'(4.6m)
Initial Delivered Lumens: 13,190
Initial FC at grade
IES Files
To obtain an IES file specific to your project consult:
http: / /www.cree.com /I ig hti ng /tools- and - support /exterior -i es- configuration -tool
' Actual production yield may vary between -4 and +10% of initial delivered lumens.
*" For more information on the IFS BUG (Backlight - Uplight- Glare) Rating visit www. iesna. org/ PDF/ Frratas/ TM- 15- 1]BugRatingsAddendum.pdf.
* ** For recommended lumen maintenance factor data see TD -13. Calculated L70 based on 6,000 hours LM -80 -08 testing: > 150,000 hours.
© 2013 Cree, Inc. All rights reserved. For informational purposes only. Content is subject to change. See
www.cree.com /patents for patents that cover these products. Cree ®, the Cree logo, BetaLED ®, NanoOptic®
and Colorfast DeltaGuard® are registered trademarks, and the BetaLED Technology logo and 304 Series'" are
trademarks of Cree, Inc.
www.cree.com /lighting T (800) 236 -6800 F (262) 504 -5415
Now
_ WW -_