HomeMy WebLinkAboutARB201400133 Staff Report Preliminary Site Plan 2014-12-08ARCHITECTURAL REVIEW BOARD STAFF REPORT
Project #/Name
ARB- 2014 -133: Stonefield D2 Townhomes
Review Type
Preliminary Review of a Final Site Development Plan
Parcel Identification
061 WO030002300
Location
On the north side of Hydraulic Road, approximately 200' east of Commonwealth Drive
Zoned
Neighborhood Model District (NMD)/Entrance Corridor (EC)
Owner /Applicant
Albemarle Realty E &A LLC /John Regan (Christopher Companies)
Magisterial District
Jack Jouett
Proposal
To construct 104 townhomes with associated site improvements.
Context
Stonefield Block D2 is situated in a mix of residential and commercial development. The Village Green shopping center is located to the west. To the east are the
Hyatt hotel and a parking lot. Across Hydraulic Road to the south are apartment buildings, a laundromat, and small scale office buildings.
Visibility
The townhome development will be visible from the Hydraulic Road Entrance Corridor. Due to the steep slope down to the site from the Hydraulic /Georgetown
corner (540' at the corner, 517' -520' for basement floor elevations and travelway), the lowest level of the Hydraulic Road - facing units won't be visible from the
road, and portions of some of the main levels will also be hidden from view. Because of the proximity of the units to Hydraulic Road and the western property
line, and because of the density of the units internal to the development, views of the internal units from the EC are expected to be limited primarily to rooftops.
Outbound traffic will have a view of the units along Inglewood Drive, where the full elevations will be visible. Smaller details of the townhome designs will be
less obvious the further north along Inglewood the units are situated. The Inglewood blocks stretch for 750' along the road.
ARB Meeting Date
December 15, 2014
Staff Contact
Margaret Maliszewski
PROJECT HISTORY
DATE
APPLICATION TYPE
RESULT
8/15/2006
SDP - 2005 -122
Preliminary site development plan approved for Albemarle Place, including Block D2.
6/24/2014
SDP - 2014 -37
Minor amendment approved for Blocks F and G.
10/6/2014
1 ARB introductory work session for the townhouse development
I ARB members made several comments, which are included in the Analysis table, below.
ANALYSIS
REF
GUIDELINE
10/6/2014 WORK SESSION COMMENTS
ISSUE
RECOMMENDATION
Structure design
1
The goal of the regulation of the design of development
Provide drawings that clarify which
The townhouse designs are a
Reconsider the color of the
within the designated Entrance Corridors is to insure that
portions of the development will be
combination of traditional and non-
shingles for the townhouse
new development within the corridors reflects the
visible from the EC.
traditional forms and features. The
roofs.
traditional architecture of the area. Therefore, it is the
3D views at the EC corners (Inglewood
development is expected to have an
purpose of ARB review and of these Guidelines, that
and Commonwealth) would be helpful.
orderly appearance, if standard planting
Reconsider the painted
proposed development within the designated Entrance
The applicant has provided perspective views
requirements are met. There are potential
brick.
Corridors reflect elements of design characteristic of the
from the EC corners that illustrate the
conflicts with the planting proposed
significant historical landmarks, buildings, and structures
visibility of the development. See
along Hydraulic Road. (See landscape
See landscape
of the Charlottesville and Albemarle area, and to promote
"Visibility" (page 1) for more information.
comments.)
recommendations.
orderly and attractive development within these corridors.
Applicants should note that replication of historic structures
Consider differentiating the corner units.
The applicant has cited the Stonefield
is neither required nor desired.
In the blocks that are most visible from the
EC, the two end units nearest the Hydraulic/
retail buildings, Charlottesville
downtown mall buildings, and buildings
3
New structures and substantial additions to existing
structures should respect the traditions of the architecture
Inglewood intersection are differentiated
at UVA as sources for the forms and
of historically significant buildings in the Charlottesville
from the other units with hipped roofs
features of the proposed townhouses.
and Albemarle area. Photographs of historic buildings in
instead of gabled roofs. One other hipped
Although these elements can be found
the area, as well as drawings of architectural features,
roof is seen in the Hydraulic Road
locally, they can also be found in many
which provide important examples of this tradition are
perspective, interior to the site.
other localities, and the proposed
contained in Appendix A.
Alternate the units forward and back to
buildings still do not have a strong local
character. However, the designs are not
9
Building forms and features, including roofs, windows,
doors, materials, colors and textures should be compatible
help break up the facades.
incompatible with the historic buildings
with the forms and features of the significant historic
As seen at the work session, the townhome
of the area.
buildings in the area, exemplified by (but not limited to) the
facades do alternate forward and back.
buildings described in Appendix A [of the design
Blocks have at least one pair of units that are
Materials presented in the work session
guidelines]. The standard of compatibility can be met
aligned, with other individual units
have been supplemented with: brick
through scale, materials, and forms which may be
projecting 2' forward or recessing 2' back.
painted white (Snowbound SW7004);
embodied in architecture which is contemporary as well as
metal roof in terra cotta; and additional
traditional. The replication of important historic sites in
Clarify the appearance of the recessed
Hardie - siding colors: Light Mist, Cobble
Albemarle County is not the objective of these guidelines.
terraces.
Stone, Monterey Taupe, Khaki Brown.
The perspective views help clarify the
Autumn tan has been deleted as a siding
appearance of the recessed terraces located at
color. The proposed materials and colors
roof level in some units. The views show that
are compatible with those approved for
the roof level windows are recessed from the
the town center and other buildings in
face of the main building wall where a
the ECs. However, the black roofs of the
shallow terrace is established.
townhome development may stand out as
a prominent feature amidst the more
The row of four windows is too
subtle tones of the rest of the
repetitive. More variety is needed.
development. Also, painted brick was an
Elevations have been revised to include
issue in the review /approval of the retail
paired windows in the Inglewood Drive
development.
facades to eliminate the long stretch of
individual windows.
The buildings look more "northern
Virginia" than "Albemarle County".
Indicate how the proposed designs relate
to traditional architecture of Albemarle
and bring context photos for reference.
The applicant has provided some photos of
local architectural elements that have been
used in the proposed designs, including
gables, paired windows, red brick, stone
veneer, railings and awnings supported by
cables.
5
It is also an important objective of the Guidelines to
The progression of the view as you travel
The proposal relies primarily on
None.
establish a pattern of compatible architectural
down Hydraulic is important. Consider
materials and colors for compatibility
characteristics throughout the Entrance Corridor in order to
the transition to the more modern style of
with the surroundings. The combination
achieve unity and coherence. Building designs should
the commercial buildings. Adding some
of colors and materials is expected to
demonstrate sensitivity to other nearby structures within the
non -red brick material to the Hydraulic
have an appropriate appearance.
Entrance Corridor. Where a designated corridor is
elevations may help with the transition.
substantially developed, these Guidelines require striking a
Consider the materials of the hotel.
careful balance between harmonizing new development
with the existing character of the corridor and achieving
The materials and palette appear
compatibility with the significant historic sites in the area.
appropriate.
The Hydraulic Road elevations were all brick
10
Buildings should relate to their site and the surrounding
context of buildings.
at the October work session. Two units in the
western block and 5 units in the eastern
12
Architecture proposed within the Entrance Corridor should
use forms, shapes, scale, and materials to create a cohesive
block have been revised from red brick to
whole.
Hardie siding in taupe or brick in a shade of
tan. The taupe and tan colors help transition
to the lighter colors of the retail part of the
development. All of the colors also
coordinate well with the materials of the
hotel.
11
The overall design of buildings should have human scale.
Alternate the units forward and back to
The townhouses are expected to feel
None.
Scale should be integral to the building and site design.
help break up the facades.
close to the road, so establishing human
The townhome facades alternate forward and
scale is important for this development.
back. Blocks have at least one pair of units
The materials, window divisions,
that are aligned, with other individual units
balconies, roof shapes and building
projecting or recessing back 2'. These
projections help establish human scale.
projections, though minimal, do help break
The drop in elevation from the EC to the
up the blocks and establish a more human
site helps mitigate the height of the
scale.
townhouses as viewed from the EC.
13
Any appearance of "blankness" resulting from building
Blankness does not appear to be an issue
None.
design should be relieved using design detail or vegetation,
with the proposed designs.
or both.
14
Arcades, colonnades, or other architectural connecting
The blocks are unified by shared
None.
devices should be used to unify groups of buildings within
materials, forms and details, and site
a development.
layout.
15
Trademark buildings and related features should be
The proposed designs aren't trademark
None.
modified to meet the requirements of the Guidelines.
buildings in the typical sense, but similar
townhouse designs may be found in
other locations.
16
Window glass in the Entrance Corridors should not be highly
Window glass has not been addressed.
Include a window glass
tinted or highly reflective. Window glass in the Entrance
note on the architectural
Corridors should meet the following criteria: Visible light
drawings that address VLT
transmittance (VLT) shall not drop below 4001o. Visible
and VLR.
light reflectance (VLR) shall not exceed 30 %.
Specifications on the proposed window glass should be
submitted with the application for final review.
Accessory structures and equipment
17
Accessory structures and equipment should be integrated
The plan shows no accessory structures,
Show all proposed
into the overall plan of development and shall, to the extent
no proposed equipment, no loading,
equipment on the plan.
possible, be compatible with the building designs used on
service or refuse areas, and no proposed
Show how the equipment
the site.
screening devices. An overhead utility
line runs along the Hydraulic Road
will be screened from view.
18
The following should be located to eliminate visibility from
the Entrance Corridor street. If, after appropriate siting, these
frontage. (See landscape comments.)
features will still have a negative visual impact on the
Entrance Corridor street, screening should be provided to
eliminate visibility. a. Loading areas, b. Service areas, c.
Refuse areas, d. Storage areas, e. Mechanical equipment, f.
Above - ground utilities, and g. Chain link fence, barbed
wire, razor wire, and similar security fencing devices.
19
Screening devices should be compatible with the design of
the buildings and surrounding natural vegetation and may
consist of: a. Walls, b. Plantings, and c. Fencing.
20
Surface runoff structures and detention ponds should be
The proposal includes no large above-
None.
designed to fit into the natural topography to avoid the need
ground stormwater features. Filterras are
for screening. When visible from the Entrance Corridor
proposed, but these are not expected to
street, these features must be fully integrated into the
have a visual impact on the EC.
landscape. They should not have the appearance of
engineered features.
44
Natural drainage patterns (or to the extent required, new
drainage patterns) should be incorporated into the finished
site to the extent possible.
21
The following note should be added to the site plan and the
The mechanical equipment note does not
Add the mechanical
architectural plan: "Visibility of all mechanical equipment
appear on the site or architectural plans.
equipment note to both the
from the Entrance Corridor shall be eliminated."
site and architectural plans.
Lighting
Light fixtures are proposed, but no
Provide a lighting plan for
lighting plan is available yet. Two of the
review.
landscape lights and the building light
are LED fixtures, so they will likely meet
ordinance requirements. The lamp type is
not identified for the path light and the
street light. The applicant has indicated
that the landscape flood light is intended
to illuminate trees in the raised green.
The green itself is not expected to be
visible from the EC, but it is not clear to
what extent the illumination in the green
will be detectable from the EC. Even if
all the fixtures meet ordinance cut -off
requirements, the quantity and intensity
of illumination could impact the EC. A
lighting plan and fixture details are
needed to determine impacts.
Landscaping
7
The requirements of the Guidelines regarding landscaping
31/2" caliper London plane trees are
Intersperse flowering
are intended to reflect the landscaping characteristic of
proposed at 35' on center along the
ornamental trees of a
many of the area's significant historic sites which is
Hydraulic Road frontage. Shrubs are
species common to the area
characterized by large shade trees and lawns. Landscaping
proposed between the trees. Six
among the London plane
should promote visual order within the Entrance Corridor
American holly are interspersed, but no
trees along the Hydraulic
and help to integrate buildings into the existing
flowering ornamentals are interspersed
Road frontage.
environment of the corridor.
along the frontage.
Provide documentation
8
Continuity within the Entrance Corridor should be obtained
by planting different types of plant materials that share
An overhead utility line runs along the
from utility /easement
similar characteristics. Such common elements allow for
Hydraulic Road planting strip. A water
holders that there is no
more flexibility in the design of structures because
line runs nearby and a series of
objection to the proposed
common landscape features will help to harmonize the
equipment access points exist along the
planting along the
appearance of development as seen from the street upon
frontage. It is not clear from the
Hydraulic Road frontage.
which the Corridor is centered.
information submitted that the planting
can be accomplished as shown.
32
Landscaping along the frontage of Entrance Corridor
streets should include the following:
a. Large shade trees should be planted parallel to the
Entrance Corridor Street. Such trees should be at least 31/2
inches caliper (measured 6 inches above the ground) and
should be of a plant species common to the area. Such trees
should be located at least every 35 feet on center.
b. Flowering ornamental trees of a species common to the
area should be interspersed among the trees required by the
preceding paragraph. The ornamental trees need not alternate
one for one with the large shade trees. They may be planted
among the large shade trees in a less regular spacing pattern.
c. In situations where appropriate, a three or four board
fence or low stone wall, typical of the area, should align the
frontage of the Entrance Corridor street.
d. An area of sufficient width to accommodate the
foregoing plantings and fencing should be reserved parallel
to the Entrance Corridor street, and exclusive of road right -
of -way and utility easements.
33
Landscaping along interior roads:
Willow Oaks are shown at 21/2" caliper,
None.
a. Large trees should be planted parallel to all interior
30' - 40' on center, along Inglewood
roads. Such trees should be at least 2%2 inches caliper
Drive.
(measured six inches above the ground) and should be of a
plant species common to the area. Such trees should be
located at least every 40 feet on center.
34
Landscaping along interior pedestrian ways:
Trees are provided along some internal
Shift trees and storm pipes
a. Medium trees should be planted parallel to all interior
sidewalks, but not all. Some trees are
as necessary to eliminate
pedestrian ways. Such trees should be at least 2%2 inches
located very close to storm pipes.
conflicts without decreasing
caliper (measured six inches above the ground) and should
the quantity of proposed
be of a species common to the area. Such trees should be
trees.
located at least every 25 feet on center.
35
Landscaping of parking areas:
There are a few groups of parking spaces
None.
a. Large trees should align the perimeter of parking areas,
proposed in the development, but no
located 40 feet on center. Trees should be planted in the
parking lots. Trees are located close to
interior of parking areas at the rate of one tree for every 10
the groups of parking spaces.
parking spaces provided and should be evenly distributed
throughout the interior of the parking area.
b. Trees required by the preceding paragraph should
measure 21/2 inches caliper (measured six inches above the
ground); should be evenly spaced; and should be of a
species common to the area. Such trees should be planted
in planters or medians sufficiently large to maintain the
health of the tree and shall be protected by curbing.
c. Shrubs should be provided as necessary to minimize the
parking area's impact on Entrance Corridor streets. Shrubs
should measure 24 inches in height.
36
Landscaping of buildings and other structures:
The townhouse blocks adjacent to
Clarify on the plan the
a. Trees or other vegetation should be planted along the
Hydraulic and Inglewood will have the
location of the cherry laurel
front of long buildings as necessary to soften the
most visibility from the EC. These
hedge.
appearance of exterior walls. The spacing, size, and type of
blocks are not excessively long. The
such trees or vegetation should be determined by the
longest blocks are 160' and 175' long,
length, height, and blankness of such walls.
and are internal to the site. The walls of
b. Shrubs should be used to integrate the site, buildings,
these blocks are not expected to be
and other structures; dumpsters, accessory buildings and
blank, and the details of these buildings
structures; "drive thru" windows; service areas; and signs.
are not expected to have an impact on the
Shrubs should measure at least 24 inches in height.
EC. A cherry laurel hedge is included on
the "site elements" sheet, but the plant
does not appear in the plant list.
37
Plant species: a. Plant species required should be as
The proposed plant species are found on
None.
approved by the Staff based upon but not limited to the
the various approved lists.
Generic Landscape Plan Recommended Species List and
Native Plants for Virginia Landscapes (Appendix D).
38
Plant health: The following note should be added to the
The plant health note appears on sheet
None.
landscape plan: "All site plantings of trees and shrubs shall
C31.
be allowed to reach, and be maintained at, mature height;
the topping of trees is prohibited. Shrubs and trees shall be
pruned minimally and only to support the overall health of
the plant."
Development pattern
6
Site development should be sensitive to the existing natural
The site has already been leveled;
See landscape
landscape and should contribute to the creation of an
significant natural features no longer
recommendations.
organized development plan. This may be accomplished, to
exist. The general layout of the site
the extent practical, by preserving the trees and rolling
appears organized. The proposed
terrain typical of the area; planting new trees along streets
buildings that front the EC are oriented
and pedestrian ways and choosing species that reflect
more or less parallel to the EC. Sidewalk
native forest elements; insuring that any grading will blend
connections are made. Significant views
into the surrounding topography thereby creating a
are not expected to be negatively
continuous landscape; preserving, to the extent practical,
impacted by this development. However,
existing significant river and stream valleys which may be
the current open view across the town
located on the site and integrating these features into the
center that is available at the Hydraulic/
design of surrounding development; and limiting the
Commonwealth corner is expected to be
building mass and height to a scale that does not overpower
limited by the construction of the
the natural settings of the site, or the Entrance Corridor.
townhouses.
39
The relationship of buildings and other structures to the
Entrance Corridor street and to other development within
The drop in elevation from the
the corridor should be as follows:
Hydraulic /Commonwealth corner to the
a. An organized pattern of roads, service lanes, bike paths,
building site helps mitigate the height of
and pedestrian walks should guide the layout of the site.
the townhouses as viewed from the EC.
b. In general, buildings fronting the Entrance Corridor
street should be parallel to the street. Building groupings
Planting new trees along Hydraulic Road
should be arranged to parallel the Entrance Corridor street.
is critical to establishing the townhouse
c. Provisions should be made for connections to adjacent
development as a coordinated segment of
pedestrian and vehicular circulation systems.
the overall town center. (See landscape
d. Open spaces should be tied into surrounding areas to
comments.)
provide continuity within the Entrance Corridor.
e. If significant natural features exist on the site (including
creek valleys, steep slopes, significant trees or rock
outcroppings), to the extent practical, then such natural
features should be reflected in the site layout. If the
provisions of Section 32.5.6.n of the Albemarle County
Zoning Ordinance apply, then improvements required by
that section should be located so as to maximize the use of
existing features in screening such improvements from
Entrance Corridor streets.
f. The placement of structures on the site should respect
existing views and vistas on and around the site.
Site Grading
40
Site grading should maintain the basic relationship of the site
Provide ground elevations on the
The site has already been graded,
None.
to surrounding conditions by limiting the use of retaining
drawings for reference.
resulting in a more or less level building
walls and by shaping the terrain through the use of smooth,
Ground elevations have been provided for
area with steep grades up to Hydraulic
rounded land forms that blend with the existing terrain. Steep
reference. They indicate that the buildings
Road on the south and the Village Green
cut or fill sections are generally unacceptable. Proposed
along Hydraulic Road will appear to rise 19'
shopping center on the west side of the
contours on the grading plan shall be rounded with a ten foot
— 40' above street level (due to the
site. Retaining walls are proposed along
minimum radius where they meet the adjacent condition.
significant difference in elevation between
a majority of the western property line.
Final grading should achieve a natural, rather than
the EC and the site). Along Inglewood Drive,
The walls reach a maximum height of
engineered, appearance. Retaining walls 6 feet in height and
the townhouses rise 40' — 44' above street
10.2'. Walls of shorter length and shorter
taller, when necessary, shall be terraced and planted to blend
level.
overall height are also found internal to
with the landscape.
the site. Given the topography and layout
of the site, the retaining walls are not
expected to have a significant visual
impact on the EC.
41
No grading, trenching, or tunneling should occur within the
The plan shows one existing London
Show tree protection
drip line of any trees or other existing features designated for
plane tree to remain in the vicinity of
fencing for the existing
preservation in the final Certificate of Appropriateness.
proposed work. Tree protection fencing
London plan tree that is to
Adequate tree protection fencing should be shown on, and
should be shown on the plan for this tree.
remain at the southeast
coordinated throughout, the grading, landscaping and erosion
corner of the site.
and sediment control plans.
42
Areas designated for preservation in the final Certificate of
Appropriateness should be clearly delineated and protected
kl"UV lu 15.1 WO) a :100117U lU 1 Biel 17:111M 113W
Staff recommends the following as the primary points of discussion:
1. The design of the townhouse units — compatibility with the traditional architecture of the area
2. The design of the townhouse units — compatibility with the Stonefield retail development
3. Materials /colors: black shingles, painted brick
Staff offers the following comments on the proposal:
1. Reconsider the color of the shingles for the townhouse roofs.
2. Reconsider the painted brick.
3. Include the window glass note on the architectural drawings: "Visible light transmittance (VLT) shall not drop below 40 %. Visible light reflectance (VLR) shall not exceed 30%. "
4. Show all proposed equipment on the plan. Show how the equipment will be screened from view.
5. Add the mechanical equipment note to both the site and architectural plans. "Visibility of all mechanical equipment from the Entrance Corridor shall be eliminated. "
6. Provide a lighting plan for review.
7. Intersperse flowering ornamental trees of a species common to the area among the London plane trees along the Hydraulic Road frontage.
8. Provide documentation from utility /easement holders that there is no objection to the proposed planting along the Hydraulic Road frontage.
9. Shift trees and storm pipes as necessary to eliminate conflicts throughout the site without decreasing the quantity of proposed trees.
10. Clarify on the plan the location of the cherry laurel hedge.
11. Show tree protection fencing for the existing London plan tree that is to remain at the southeast corner of the site.
10
on the site prior to any grading activity on the site. This
protection should remain in place until completion of the
development of the site.
43
Preservation areas should be protected from storage or
movement of heavy equipment within this area.
kl"UV lu 15.1 WO) a :100117U lU 1 Biel 17:111M 113W
Staff recommends the following as the primary points of discussion:
1. The design of the townhouse units — compatibility with the traditional architecture of the area
2. The design of the townhouse units — compatibility with the Stonefield retail development
3. Materials /colors: black shingles, painted brick
Staff offers the following comments on the proposal:
1. Reconsider the color of the shingles for the townhouse roofs.
2. Reconsider the painted brick.
3. Include the window glass note on the architectural drawings: "Visible light transmittance (VLT) shall not drop below 40 %. Visible light reflectance (VLR) shall not exceed 30%. "
4. Show all proposed equipment on the plan. Show how the equipment will be screened from view.
5. Add the mechanical equipment note to both the site and architectural plans. "Visibility of all mechanical equipment from the Entrance Corridor shall be eliminated. "
6. Provide a lighting plan for review.
7. Intersperse flowering ornamental trees of a species common to the area among the London plane trees along the Hydraulic Road frontage.
8. Provide documentation from utility /easement holders that there is no objection to the proposed planting along the Hydraulic Road frontage.
9. Shift trees and storm pipes as necessary to eliminate conflicts throughout the site without decreasing the quantity of proposed trees.
10. Clarify on the plan the location of the cherry laurel hedge.
11. Show tree protection fencing for the existing London plan tree that is to remain at the southeast corner of the site.
10
TABLE A This report is based on the following submittal items:
Sheet
Drawing Name
Date
Sheet
Drawing Name
Date
Materials Sample Board
C7
Key Plan
-
3
Hydraulic Road streetscape
-
Precast 1 & 2: Rockcast, Buffstone, Sandstone
C8
Site Layout Plan
11 -4 -14
4
Inglewood Drive streetscape
-
Trim Paint: Sherwin Williams 7567 Natural Tan
C9
Site Layout Plan
11 -4 -14
5
Inglewood Drive community entrance
-
Brick 1, 2 and 3: Glen -Gery, Provincetown, Smokey Quartz, painted Sherwin
Williams Snowbound 7004
C10
Grading and Drainage Plan
11 -4 -14
6
View from green
-
Siding 1, 2, 3, 4, and 5: James Hardie, Light Mist, Navajo Beige, Cobble
Stone, Monterey Taupe, Khaki Brown
C11
Grading and Drainage Plan
11 -4 -14
7
Hydraulic Rd. perspective
-
Stone Veneer: Quality Stone Veneer, Luray, Dry Stack (photocopy)
C12
Water & Sanitary Sewer Layout Plan
11 -4 -14
8
Hydraulic Rd. Inglewood Dr. perspective
-
I Roof Shingles: Owens Coming, Onyx Black
C13
Water & Sanitary Sewer Layout Plan
11 -4 -14
9
Floor plans A B
-
Windows/Doors: Jeld -Wen Chestnut Bronze
C29
Landscape Plan
11 -4 -14
10
Floor plans A B
-
Entry Doors: Sherwin Williams 2803 Rockwood Terra Cotta
C30
Landscape Plan
11 -4 -14
11
Floor plans C D
-
Rails: Dark bronze aluminum
C31
Landscape Details
11 -4 -14
12
Floor plans C D
-
Bays: Painted to match dark bronze rails
1
Architectural Plan
13
Charlottesville & Stonefield Architecture
-
Metal roof: Englert, Terra Cotta
2
Community Entrance & Green
-
14
Site Elements & Lighting
-
11