Loading...
HomeMy WebLinkAboutSDP201300063 Review Comments Final Site Plan and Comps. 2014-11-24YlAGIl`11A County of Albemarle Department of Community Development Project: Cole's Import Specialist — Final (SDP- 2013 - 00063) Plan preparer: Meridian Planning Group, LLC Engineer: Meridian Planning Group, LLC Plan received date: 17 Nov 2014 Date of comments: 24 Nov 2014 Reviewer: Michelle Roberge The engineering comments regarding the final site plan application for Cole's Import Specialist are provided below. Comments to address for Final Site Plan: 1. [Comment] Provide ADT on C -001. [Revision 11 Comment addressed. 2. [Comment] All topography should be field verified by designer within the last year. Provide date and source of topographic information. [Revision 11 Comment addressed. 3. [Comment] On sheet C -201, show new tree line and sight distance at entrance to verify sight distance requirements are met. [Revision 11 Comment addressed. 4. [Comment] Provide a 20' travelway instead of 14' travelway. [Revision 11 Comment not addressed. We discussed putting a sign for employees only. 5. [Comment] The existing sanitary easements shall be provided with the deed book reference. [Revision 11 Comment not addressed. 6. [Comment] Proposed topography should be at a minimum of 2' contour intervals. Please show 2' proposed contours on plan. [Revision 11 Comment addressed. 7. [Comment] Slightly revise spot elevation to maintain a 4% grade at entrance. [Revision 11 Comment addressed. 8. [Comment] For possible future connections, please provide grading easements within this site that will be required to construct connection. [Revision 11 Comment not addressed. This is shown on plans but a plat will need to be submitted for review. 9. [Comment] It appears water will flow to TMP 45 -100A from proposed fixture connection. I recommend showing a curb or provide a high pt to create a drainage divide. [Revision 11 Comment partially addressed. Please label asphalt curb. Current Development Engineering Review Comments Page 2 of 2 10. [Comment] VDOT approval is required for the entrance waiver request. [Revision 11 Comment addressed. 11. [Comment] Label CG -2 on C -201. [Revision 11 Comment addressed. 12. [Comment] Show a minimum of 3' radius for curbed islands. [Revision 11 Comment addressed. 13. [Comment] I recommend raising the retaining wall. I also recommend a guardrail between travelway and retaining wall. Use VDOT standards for placement and type of guardrail. [Revision 11 Comment addressed. 14. [Comment] Provide a detail of railing on retaining wall. [Revision 11 Comment partially addressed. Please show actual design of retaining wall. The handrail appears to be missing the footing. 15. [Comment] The limits of disturbance for retaining wall will encroach on TMP 45 -100A. Please show the correct limits of grading and limits of disturbance. [Revision 11 Comment addressed. New Comment 16. Please remove VRRM info on site plan. 17. Please remove E &S sheets from the site plan. 18. Please remove PPP sheets from the site plan. 19. Please remove note from title sheet that states volume control is not required. 20. Please remove E &S, SWM and SWPP from title. This should only be labeled Final Site Plan. 21. Please revise BMP type on title sheet to match the VSMP application. Please contact Michelle Roberge in the Engineering Dept at mroberee(&albemarle.org or 434 - 296 -5832 ext. 3458 for further information.