Loading...
HomeMy WebLinkAboutSDP201300063 Review Comments Final Site Plan and Comps. 2015-01-30YlAGIl`11A County of Albemarle Department of Community Development Project: Cole's Import Specialist — Final (SDP- 2013 - 00063) Plan preparer: Meridian Planning Group, LLC Engineer: Meridian Planning Group, LLC Plan received date: 12 Jan 2014 Date of comments: 30 Jan 2014 Reviewer: Michelle Roberge The engineering comments regarding the final site plan application for Cole's Import Specialist are provided below. Comments to address for Final Site Plan: 1. [Comment] Provide ADT on C -001. [Revision 11 Comment addressed. 2. [Comment] All topography should be field verified by designer within the last year. Provide date and source of topographic information. [Revision 11 Comment addressed. 3. [Comment] On sheet C -201, show new tree line and sight distance at entrance to verify sight distance requirements are met. [Revision 11 Comment addressed. 4. [Comment] Provide a 20' travelway instead of 14' travelway. [Revision 11 Comment not addressed. We discussed putting a sign for employees only. [Revision 21 Comment addressed. 5. [Comment] The existing sanitary easements shall be provided with the deed book reference. [Revision 11 Comment not addressed. [Revision 21 Comment addressed. 6. [Comment] Proposed topography should be at a minimum of 2' contour intervals. Please show 2' proposed contours on plan. [Revision 11 Comment addressed. 7. [Comment] Slightly revise spot elevation to maintain a 4% grade at entrance. [Revision 11 Comment addressed. 8. [Comment] For possible future connections, please provide grading easements within this site that will be required to construct connection. [Revision 11 Comment not addressed. This is shown on plans but a plat will need to be submitted for review. [Revision 21 Comment addressed. Review in process. Current Development Engineering Review Comments Page 2 of 3 9. [Comment] It appears water will flow to TMP 45 -100A from proposed future connection. I recommend showing a curb or provide a high pt to create a drainage divide. [Revision 11 Comment partially addressed. Please label asphalt curb. [Revision 21 Comment addressed. 10. [Comment] VDOT approval is required for the entrance waiver request. [Revision 11 Comment addressed. 11. [Comment] Label CG -2 on C -201. [Revision 11 Comment addressed. 12. [Comment] Show a minimum of 3' radius for curbed islands. [Revision 11 Comment addressed. 13. [Comment] I recommend raising the retaining wall. I also recommend a guardrail between travelway and retaining wall. Use VDOT standards for placement and type of guardrail. [Revision 11 Comment addressed. 14. [Comment] Provide a detail of railing on retaining wall. [Revision 11 Comment partially addressed. Please show actual design of retaining wall. The handrail appears to be missing the footing. [Revision 21 Comment addressed. 15. [Comment] The limits of disturbance for retaining wall will encroach on TMP 45 -100A. Please show the correct limits of grading and limits of disturbance. [Revision 11 Comment addressed. 16. Please remove VRRM info on site plan. [Revision 21 Comment not addressed. Include 302 -303 with a VSMP plan /package: Include E &S, PPP and SWM plan (C302- C303). The name of the plan should include VSMP, E &S, PPP and SWM plan. 17. Please remove E &S sheets from the site plan. [Revision 21 Comment addressed. 18. Please remove PPP sheets from the site plan. [Revision 21 Comment addressed. 19. Please remove note from title sheet that states volume control is not required. [Revision 21 Comment addressed. 20. Please remove E &S, SWM and SWPP from title. This should only be labeled Final Site Plan. [Revision 21 Comment addressed. 21. Please revise BMP type on title sheet to match the VSMP application. [Revision 21 Comment addressed partially. It should be on the title sheet of VSMP plan /package also. Current Development Engineering Review Comments Page 3 of 3 Please contact Michelle Roberge in the Engineering Dept at mrobergekalbemarle.org or 434 - 296 -5832 ext. 3458 for further information.