HomeMy WebLinkAboutARB201500005 Staff Report Final Site Plan and Comps. 2015-02-23ARCHITECTURAL REVIEW BOARD STAFF REPORT
Project #/Name
ARB- 2015 -05: Cascadia Blocks 1— 3 Final Plan
Review Type
Final Site Development Plan
Parcel Identification
07800000005900, 078000000059A0, 078E00000000H1, 06200000002500
Location
On the east side of Stony Point Road (Rt. 20), approximately 350' north of Fontana Drive
Zoned
Neighborhood Model District (NMD)/Entrance Corridor (EC)
Owner /Applicant
Cascadia Development LLC /Clint Shifflett
Magisterial District
Rivanna
Proposal
To construct 48 duplexes, 52 townhouse units, 19 single family detached residences, and a 10,000 square foot commercial building, with associated site improvements, as
part of a larger development.
Context
This site is bounded on the south by the Montessori school, on the north by the Broadus Baptist Memorial Church, and on the west by the Route 20 Entrance Corridor.
Visibility
The blocks of residential units will be visible stepping up the slope, but landscaping in the entry park along the EC will filter views up the slope, and mature landscaping
internal to the development will eventually limit much of the view. The commercial building proposed to be located north of the entrance road will be visible from the EC.
ARB Meeting Date
March 2, 2015
Staff Contact
Margaret Maliszewski
PROJECT HISTORY
DATE
APPLICATION
RESULT
2004, 2005
ZMA2002 -04: Cascadia
The ARB provided advisory comments on the rezoning application for this proposal. The rezoning was approved in 2006. The
a roved Application Plan and Code of Development guide the layout and other features of the development.
Feb. 3, 2014
ARB- 2013 -186: Cascadia Blocks 4 -7
The ARB approved, with conditions, the plan for Cascadia Blocks 4 -7. A Certificate of Appropriateness was issued for Blocks
4 -7 on August 12, 2014. This approval included most of the landscaping in Block 1 adjacent to the Rt. 20 EC.
Sep. 15, 2014
ARB- 2014 -114: Cascadia Blocks 1 -3 Initial Site Plan
The ARB reviewed the Initial Site Plan for Blocks 1 -3. Comments from the ARB meeting are included in the Analysis, below.
Sep. 30, 2014
SDP - 2014 -57: Cascadia Blocks 1 -3 Initial Site Plan
The Initial Site Plan was approved.
ANALYSIS
REF
GUIDELINE
9/15/2014 ARB COMMENT
CURRENT COMMENT /ISSUE
RECOMMENDATIONS
Structure design
1
The goal of the regulation of the design of development within
Note that a "back of building"
Sections have been provided through the site from
Provide architectural
the designated Entrance Corridors is to insure that new
appearance will not be appropriate for
the north and south ends of the EC frontage, but not
elevations for the
development within the corridors reflects the traditional
any buildings visible from the EC.
through the commercial building. Although the
commercial building.
architecture of the area. Therefore, it is the purpose of ARB
footprint of the commercial building is shown on the
Ensure that the north,
review and of these Guidelines, that proposed development
Provide a site section taken through the
plan, the architectural design for the building has
south and west elevations
within the designated Entrance Corridors reflect elements of
EC, the commercial building, and the
not been submitted for review.
are fully designed with an
design characteristic of the significant historical landmarks,
residential units above.
appropriate appearance for
buildings, and structures of the Charlottesville and Albemarle
The sections suggest that mature trees will
the EC.
area, and to promote orderly and attractive development within
eventually screen much of the residential units from
these corridors. Applicants should note that replication of historic
view, with somewhat increased visibility when the
structures is neither required nor desired.
leaves are off the trees.
3
New structures and substantial additions to existing structures
should respect the traditions of the architecture of historically
The commercial building is expected to be visible
significant buildings in the Charlottesville and Albemarle area.
from the EC. The site layout suggests that the rear
Photographs of historic buildings in the area, as well as
elevation of the building faces the EC. Typically,
drawings of architectural features, which provide important
the ARB has not approved a final site plan with a
examples of this tradition are contained in Appendix A.
building footprint whose architectural design has not
yet been reviewed and approved.
4
The examples contained in Appendix A should be used as a
guide for building design: the standard of compatibility with
the area's historic structures is not intended to impose a rigid
design solution for new development. Replication of the design
of the important historic sites in the area is neither intended nor
desired. The Guideline's standard of compatibility can be met
through building scale, materials, and forms which may be
embodied in architecture which is contemporary as well as
traditional. The Guidelines allow individuality in design to
accommodate varying tastes as well as special functional
requirements.
9
Building forms and features, including roofs, windows, doors,
The residential units use building forms and scale
materials, colors and textures should be compatible with the
that reflect those of historic buildings in the area.
forms and features of the significant historic buildings in the
Proposed materials — Hardie siding and asphalt
area, exemplified by (but not limited to) the buildings described
shingles — are compatible with the historic materials
in Appendix A [of the design guidelines]. The standard of
of the area.
compatibility can be met through scale, materials, and forms
which may be embodied in architecture which is contemporary
The architectural design of the commercial building
as well as traditional. The replication of important historic sites
has not been submitted for review.
in Albemarle County is not the objective of these guidelines.
11
The overall design of buildings should have human scale. Scale
The size, forms and details of the residential units
No comments on the
should be integral to the building and site design.
establish human scale.
residential units.
12
Architecture proposed within the Entrance Corridor should use
The appearance of the residential units is expected
Comments on the
forms, shapes, scale, and materials to create a cohesive whole.
to appear cohesive within the corridor.
commercial building will
13
Any appearance of "blankness" resulting from building design
Blankness is not an issue with the residential design.
be provided after designs
should be relieved using design detail or vegetation, or both.
The site layout suggests that the rear elevation of the
are submitted for review.
commercial building will face the EC, so blankness
could be an issue with that building.
14
Arcades, colonnades, or other architectural connecting devices
Many of the residential units are grouped together as
should be used to unify groups of buildings within a
attached units.
development.
15
Trademark buildings and related features should be modified to
The residential design has been used in other
meet the requirements of the Guidelines.
developments, but the houses are not expected to
appear as trademark designs.
16
Window glass in the Entrance Corridors should not be highly
Details on window glass were not submitted. The
Add the standard window
tinted or highly reflective. Window glass in the Entrance
note will be needed on the drawings.
glass note to the
Corridors should meet the following criteria: Visible light
architectural drawings.
transmittance (VLT) shall not drop below 4001o. Visible light
reflectance (VLR) shall not exceed 30%. Specifications on the
proposed window glass should be submitted with the
application forfinal review.
5
It is also an important objective of the Guidelines to establish a
The residential units are compatible with other
Provide architectural
pattern of compatible architectural characteristics throughout
residences in the corridor.
elevations for the
the Entrance Corridor in order to achieve unity and coherence.
commercial building.
Building designs should demonstrate sensitivity to other nearby
It will be especially important for the commercial
Ensure that the north,
structures within the Entrance Corridor. Where a designated
building to have an appropriate and compatible
south and west elevations
corridor is substantially developed, these Guidelines require
appearance, given its proximity to the EC and its
are fully designed with an
striking a careful balance between harmonizing new
location at the entrance to the development.
appropriate appearance for
development with the existing character of the corridor and
the EC.
achieving compatibility with the significant historic sites in the
area.
10
Buildings should relate to their site and the surrounding context
of buildings.
Accessory structures and equipment
17
Accessory structures and equipment should be integrated into
Include a dumpster screen detail in the
The dumpster detail has not been provided. The
Include a dumpster screen
the overall plan of development and shall, to the extent
plan. Identify the material of the screen
applicant indicates that it will be provided with the
detail in the plan. Identify
possible, be compatible with the building designs used on the
on the plan. Coordinate the screen
commercial building.
the material of the screen
site.
material with the building material.
on the plan. Coordinate
the screen material with
18
The following should be located to eliminate visibility from the
It is anticipated that standard residential scale
Entrance Corridor street. If, after appropriate siting, these features
mechanical and refuse related equipment /items will
the material of the
will still have a negative visual impact on the Entrance Corridor
be located in the yards of the residential units. With
commercial building.
street, screening should be provided to eliminate visibility.
many back yards facing the EC, it is likely that
a. Loading areas,
some of these items will have some visibility from
b. Service areas,
the EC. The landscaping located close to the EC will
c. Refuse areas,
help filter these views. This level of visibility isn't
d. Storage areas,
expected to have a negative impact on the EC. No
e. Mechanical equipment,
loading or service areas are proposed in the
f. Above - ground utilities, and
residential sections of the development.
g. Chain link fence, barbed wire, razor wire, and similar
security fencing devices.
19
Screening devices should be compatible with the design of the
buildings and surrounding natural vegetation and may consist
of:
a. Walls,
b. Plantings, and
c. Fencing.
20
Surface runoff structures and detention ponds should be designed
Stormwater management features are shown
None.
to fit into the natural topography to avoid the need for screening.
generally as approved with the rezoning and Blocks
When visible from the Entrance Corridor street, these features
4 -7 site plan.
must be fully integrated into the landscape. They should not have
the appearance of engineered features.
44
Natural drainage patterns (or to the extent required, new
drainage patterns) should be incorporated into the finished site
to the extent possible.
21
The following note should be added to the site plan and the
Add the mechanical equipment note to
The note has been added to the site plan.
None.
architectural plan: "Visibility of all mechanical equipment from
the plan.
the Entrance Corridor shall be eliminated."
Lighting
If lighting is proposed, provide a
No lighting is proposed.
None.
complete lighting plan for review.
Landscaping
7
The requirements of the Guidelines regarding landscaping are
Revise the site plan to show the
The approved frontage planting is shown on the
Add landscaping along the
intended to reflect the landscaping characteristic of many of the
approved frontage planting for Blocks
plan, together with additional proposed landscaping.
frontage at the southwest
area's significant historic sites which is characterized by large
4 -7.
corner of the development,
shade trees and lawns. Landscaping should promote visual
The row of shrubs west of pond #1 was removed,
consistent with the
order within the Entrance Corridor and help to integrate
Revise the regular row of shrubs west of
but not replaced with alternate plants.
approved planting to the
buildings into the existing environment of the corridor.
stormwater pond #1 to a mix of shrubs
in an irregular layout consistent with the
Landscaping was added at the east end, but not in
north, to blend this end of
the frontage with the area
8
Continuity within the Entrance Corridor should be obtained by
planting different types of plant materials that share similar
approved planting to the north.
the southwest corner of pond #1. The plan shows
to the north.
characteristics. Such common elements allow for more
some groups of existing trees to remain in this area.
flexibility in the design of structures because common
Add landscaping at the southwest
It is anticipated that the result will be an inconsistent
landscape features will help to harmonize the appearance of
corner and east end of stormwater pond
appearance along the frontage. Providing planting at
development as seen from the street upon which the Corridor is
#1, consistent with the approved
the southwest corner, consistent with the approved
centered.
planting to the north, to blend this end
of the frontage with the area to the
planting to the north, would establish a more
cohesive appearance for the development as viewed
32
Landscaping along the frontage of Entrance Corridor streets
should include the following:
north.
from the EC.
a. Large shade trees should be planted parallel to the Entrance
Corridor Street. Such trees should be at least 3% inches caliper
(measured 6 inches above the ground) and should be of a plant
species common to the area. Such trees should be located at
least every 35 feet on center.
b. Flowering ornamental trees of a species common to the area
should be interspersed among the trees required by the preceding
paragraph. The ornamental trees need not alternate one for one
with the large shade trees. They may be planted among the large
shade trees in a less regular spacing pattern.
c. In situations where appropriate, a three or four board fence or
low stone wall, typical of the area, should align the frontage of
the Entrance Corridor street.
d. An area of sufficient width to accommodate the foregoing
plantings and fencing should be reserved parallel to the
Entrance Corridor street, and exclusive of road right -of -way
and utility easements.
33
Landscaping along interior roads:
Provide large shade trees parallel to all
More street trees are proposed than were shown
Provide large shade trees
a. Large trees should be planted parallel to all interior roads.
interior roads, 40' on center, 2'/2"
previously, but many gaps still appear where pipes
parallel to all interior
Such trees should be at least 2%2 inches caliper (measured six
caliper at planting. Shift pipes and
are located between the sidewalk and the street. This
roads, 40' on center, 2%2"
inches above the ground) and should be of a plant species
utilities to accommodate these trees.
includes a gap in the row of street trees where a pipe
caliper at planting. Shift
common to the area. Such trees should be located at least every
runs along the north side of the entrance into the
pipes and utilities to
40 feet on center.
development. Trees on both sides of the entrance
road would provide a more balanced, finished and
accommodate these trees.
34
Landscaping along interior pedestrian ways:
a. Medium trees should be planted parallel to all interior
appropriate appearance for the EC.
Adjust utilities to provide
pedestrian ways. Such trees should be at least 2'/2 inches caliper
trees on both sides of the
(measured six inches above the ground) and should be of a
entrance road into the
species common to the area. Such trees should be located at
development from Rt. 20.
least every 25 feet on center.
35
Landscaping of parking areas:
Provide 2'/2" caliper perimeter parking
London plane trees and cryptomeria have been
See #40.
a. Large trees should align the perimeter of parking areas,
lot trees for the commercial building in
provided at the parking lot. A row of arborvitae is
located 40 feet on center. Trees should be planted in the interior
Block 1. Provide a quantity of trees
proposed at the base of the retaining wall.
of parking areas at the rate of one tree for every 10 parking
equivalent to 40' on center, coordinated
spaces provided and should be evenly distributed throughout
with the entry park trees and the
the interior of the parking area.
retaining wall.
b. Trees required by the preceding paragraph should measure
2'/2 inches caliper (measured six inches above the ground);
should be evenly spaced; and should be of a species common to
the area. Such trees should be planted in planters or medians
sufficiently large to maintain the health of the tree and shall be
protected by curbing.
c. Shrubs should be provided as necessary to minimize the
parking area's impact on Entrance Corridor streets. Shrubs
should measure 24 inches in height.
36
Landscaping of buildings and other structures:
Revise the plan to show the trees in the
The trees have been shifted as requested.
Provide architectural
a. Trees or other vegetation should be planted along the front of
back yards of lots 22 -29 on the entry
elevations for the
long buildings as necessary to soften the appearance of exterior
park side of the property line.
A row of cryptomeria is proposed on the west (EC)
commercial building.
walls. The spacing, size, and type of such trees or vegetation
side of the commercial building. This could provide
Ensure that the north,
should be determined by the length, height, and blankness of
screening for the empty building pad, but it also
south and west elevations
such walls.
suggests that the EC elevation will have an
are fully designed with an
b. Shrubs should be used to integrate the site, buildings, and
appearance that requires screening.
appropriate appearance for
other structures; dumpsters, accessory buildings and structures;
the EC.
"drive thru" windows; service areas; and signs. Shrubs should
measure at least 24 inches in height.
37
Plant species:
The proposed plants are found on the various lists.
None.
a. Plant species required should be as approved by the Staff
based upon but not limited to the Generic Landscape Plan
Recommended Species List and Native Plants for Virginia
Landscapes (Appendix D).
a38
Plant health:
Add the standard plant health note to
The note has been added to the plan.
None.
The following note should be added to the landscape plan: "All
the plan.
site plantings of trees and shrubs shall be allowed to reach, and
be maintained at, mature height; the topping of trees is
prohibited. Shrubs and trees shall be pruned minimally and
only to support the overall health of the plant."
Development pattern
6
Site development should be sensitive to the existing natural
Issues regarding tree preservation, open space,
Provide architectural
landscape and should contribute to the creation of an organized
natural features, views and pedestrian connections
elevations for the
development plan. This may be accomplished, to the extent
were resolved with the rezoning.
commercial building.
practical, by preserving the trees and rolling terrain typical of
Ensure that the north,
the area; planting new trees along streets and pedestrian ways
The footprint of the commercial building is shown
south and west elevations
and choosing species that reflect native forest elements;
on the plan but the architectural designs have not
are fully designed with an
insuring that any grading will blend into the surrounding
been provided for review. The layout suggests that
appropriate appearance for
topography thereby creating a continuous landscape;
the rear elevation will face the EC.
the EC.
preserving, to the extent practical, existing significant river and
stream valleys which may be located on the site and integrating
these features into the design of surrounding development; and
limiting the building mass and height to a scale that does not
overpower the natural settings of the site, or the Entrance
Corridor.
39
The relationship of buildings and other structures to the
Entrance Corridor street and to other development within the
corridor should be as follows:
a. An organized pattern of roads, service lanes, bike paths, and
pedestrian walks should guide the layout of the site.
b. In general, buildings fronting the Entrance Corridor street
should be parallel to the street. Building groupings should be
arranged to parallel the Entrance Corridor street.
c. Provisions should be made for connections to adjacent
pedestrian and vehicular circulation systems.
d. Open spaces should be tied into surrounding areas to provide
continuity within the Entrance Corridor.
e. If significant natural features exist on the site (including
creek valleys, steep slopes, significant trees or rock
outcroppings), to the extent practical, then such natural features
should be reflected in the site layout. If the provisions of
Section 32.5.6.n of the Albemarle County Zoning Ordinance
apply, then improvements required by that section should be
located so as to maximize the use of existing features in
screening such improvements from Entrance Corridor streets.
f. The placement of structures on the site should respect
existing views and vistas on and around the site.
Site Grading
40
Site grading should maintain the basic relationship of the site to
At the east end of stormwater
Most of the contours have been rounded as
Terrace portions of the
surrounding conditions by limiting the use of retaining walls and
management pond #1, round contours
requested.
retaining wall at the
by shaping the terrain through the use of smooth, rounded land
with a ten foot minimum radius where
commercial building that
forms that blend with the existing terrain. Steep cut or fill sections
they meet the adjacent condition.
A cut sheet illustrating the proposed retaining wall
are 6' tall or taller.
are generally unacceptable. Proposed contours on the grading
block has been submitted separate from the plan.
Provide planting on the
plan shall be rounded with a ten foot minimum radius where they
Indicate on the plan the material and
The proposed block is Anchor Block, Highland
terraces. Provide the
meet the adjacent condition. Final grading should achieve a
color proposed for the retaining wall.
Stone. A specific color has not been identified.
retaining wall details in
natural, rather than engineered, appearance. Retaining walls 6 feet
Terrace walls over 6' tall. Use
the site plan for review.
in height and taller, when necessary, shall be terraced and planted
landscaping to soften the visual impacts
The referenced retaining wall extends to the
Indicate the block
to blend with the landscape.
of the wall.
northeast from the northeast corner of the
manufacturer, style and
commercial building. It reaches a maximum height
color on the plans.
of 13', and it is not terraced. A row of arborvitae is
shown along parts of the wall.
Another retaining wall, reaching a height of 16' is
proposed north of lot 22 and Marietta Drive. It is not
terraced. Existing wooded area to remain is shown
to the north of the wall, and a new planting of
staggered cryptomeria and deciduous trees are
proposed on the west side and northwest corner.
41
No grading, trenching, or tunneling should occur within the drip
Include a conservation checklist in the
The conservation checklist is provided on the cover
Submit for the review the
line of any trees or other existing features designated for
plan. Show tree protection fencing.
sheet of the site plan. The applicant has indicted that
E &S plan showing tree
preservation in the final Certificate of Appropriateness. Adequate
tree protection fencing is shown on the E &S plan,
protection fencing.
tree protection fencing should be shown on, and coordinated
but that plan was not submitted for review.
13" Ov lu /:33Y17a11XQ1QUluI Biel 711Y113M
Staff recommends the following as the primary points of discussion:
1. Commercial building elevations; timing of review
2. Retaining wall at the commercial building; terracing, landscaping
3. Landscaping at the southwest corner of the site
Staff offers the following comments on the plan:
1. Provide architectural elevations for the commercial building. Ensure that the north, south and west elevations are fully designed with an appropriate appearance for the EC.
2. Add the standard window glass note to the architectural drawings: "Visible Light Transmittance (VLT) shall not drop below 40 %. Visible Light Reflectance (VLR) shall not exceed 30 %."
3. Include a dumpster screen detail in the plan. Identify the material of the screen on the plan. Coordinate the screen material with the material of the commercial building.
4. Add landscaping along the frontage at the southwest corner of the development, consistent with the approved planting to the north, to blend this end of the frontage with the area to the north.
5. Provide large shade trees parallel to all interior roads, 40' on center, 2'/2" caliper at planting. Shift pipes and utilities to accommodate these trees.
6. Adjust utilities to provide trees on both sides of the entrance road into the development from Rt. 20.
7. Terrace portions of the retaining wall at the commercial building that are 6' tall or taller. Provide planting on the terraces. Provide the retaining wall details in the site plan for review. Indicate the
block manufacturer, style and color of the block on the plans.
8. Submit for the review the E &S plan showing tree protection fencing.
throughout, the grading, landscaping and erosion and sediment
control plans.
42
Areas designated for preservation in the final Certificate of
Appropriateness should be clearly delineated and protected on
the site prior to any grading activity on the site. This protection
should remain in place until completion of the development of
the site.
43
Preservation areas should be protected from storage or
movement of heavy equipment within this area.
13" Ov lu /:33Y17a11XQ1QUluI Biel 711Y113M
Staff recommends the following as the primary points of discussion:
1. Commercial building elevations; timing of review
2. Retaining wall at the commercial building; terracing, landscaping
3. Landscaping at the southwest corner of the site
Staff offers the following comments on the plan:
1. Provide architectural elevations for the commercial building. Ensure that the north, south and west elevations are fully designed with an appropriate appearance for the EC.
2. Add the standard window glass note to the architectural drawings: "Visible Light Transmittance (VLT) shall not drop below 40 %. Visible Light Reflectance (VLR) shall not exceed 30 %."
3. Include a dumpster screen detail in the plan. Identify the material of the screen on the plan. Coordinate the screen material with the material of the commercial building.
4. Add landscaping along the frontage at the southwest corner of the development, consistent with the approved planting to the north, to blend this end of the frontage with the area to the north.
5. Provide large shade trees parallel to all interior roads, 40' on center, 2'/2" caliper at planting. Shift pipes and utilities to accommodate these trees.
6. Adjust utilities to provide trees on both sides of the entrance road into the development from Rt. 20.
7. Terrace portions of the retaining wall at the commercial building that are 6' tall or taller. Provide planting on the terraces. Provide the retaining wall details in the site plan for review. Indicate the
block manufacturer, style and color of the block on the plans.
8. Submit for the review the E &S plan showing tree protection fencing.
TABLE A
This report is based on the following submittal items:
Site Plan
ARCHITECTURAL
Sheet #
Drawing Name
Drawing Date
Sheet #
Drawing Name
Drawing Date
SP1
Cover Sheet
12/1/14
1
Cover Sheet
-
SP2
Notes, Abbreviations & Legend
12/1/14
2
Photos from Stony Point Rd.
-
SP3
Road Sections & Code of Development Tables
12/1/14
3
Photos from Stony Point Rd.
-
SP4
Existing Conditions
12/1/14
4
Perspective from Photo 1
-
SP5
Subdivision Overview
12/1/14
5
Perspective from Photo 8
-
SP5A
Building Block Plan/Phasing Plan
12/1/14
6
Perspective from Photo 7
-
SP6
Site Plan
12/1/14
7
Perspective from Photo 3
-
SP7
Site Plan
12/1/14
8
Perspective from Photo 5
-
SP8
Site Plan
12/1/14
9
Duplex Elevations
Nov. 22, 2013
SP9
Site Plan
12/1/14
10
Duplex Elevations
Nov. 22, 2013
SP26
Landscape Plan
12/1/14
11
Material Selections
-
SP27
Landscape Plan
12/1/14
SP28
Landscape Plan
12/1/14
SP29
Landscape Plan
12/1/14
SP 30
Landscape Plan
12/1/14
APP 1
Viewshed Along Route 20
1 12/23/14
APP 2
Viewshed Along Route 20 and Wall Spec. Sheets
1 12/23/14
10