HomeMy WebLinkAboutARB201000010 Legacy Document 2010-03-15F7
AL EXISTING:
D/F INTERNALLY ILLUMINATED
MONUMENT SIGN
_ W7
EXISTING:
EXTERNALLY ILLUMINATED
PANEL SIGN WITH LOGO
W2
EXISTING:
INTERNALLY ILLUMINATED
CHANNEL LETTERS
W1
EXISTING:
NON- ILLUMINATED
AWNING WITH
• LOGO
IVY ROAD
SIGN DESCR. EXISTING SIGNS
1 ELIMINATED SIGNS
PROPOSED SIGNS
I HAVE CAREFULLY REVIEWED AND HEREBY ACCEPT
THE DRAWING(S) AS SHOWN. I REALIZETHATANY
CHANGES TO THESE DESIGNS MADE BEFORE OR
AFTER PRODUCTION MAY ALTER THE CONTRACT
PRICE. ALL CHANGES MUST BE IN WRITING AND
APPROVED BY BOTH PARTIES PRIOR TO PRODUCTION.
SIGNATURE& DATE
THE CUSTOM ARTWORK DEPICTED HEREIN IS
FOR REPRESENTATIONAL PURPOSES ONLY
AND MAY NOT EXACTLY MATCH THE COLORS
OF THE MATERIALS PROPOSED FOR USAGE.
ELECTRIC SIGNS PRODUCED AT
IMAGE WORKS CONFORM TO UL 48
L STANDARDS AND DISPLAYTHE
UNDERWRITERS LABORATORIES LABEL.
ALL ONSITE PRIMARY ELECTRICAL CONNECTIONS BY OTHERS.
DATE REVISION DESCRIPTION DESIGNER
11046 LEADBETTER ROAD ASHLAND VIRGINIA 23005
PHONE 804.798.5533 FAX 804.798.5582
UNION FIRST MARKET BANK
DRAWING IDENTIFICATION
CLIENT
CHARLOTTESVILLE, VA
LOCATION
KARL UFTRING
SALE REPRESENTATIVE
WAM
DESIGNER
9.23.09
DATE PREPARED
NOT TO SCALE
SCALE
UFMB -0001 CHA -01
PROJECTID
SITE PLAN
DRAWING IDENTIFICATION
2" X 1/4" STEEL ANGLE SADDLES,5 3/4" SADDDLE
RADIUS END CABINET PAINTED SATIN FINISH BLACK,
WITH ROUTED ALUMINUM FACE
AI 1/2" CLEAR ACRYLIC PUSH - THROUGH WITH
FIRST AND SECOND SURFACE VINYL 3M 3630 -156 VIVID GREEN
_ 00
'UNION'- 1/2" CLEAR ACRYLIC PUSH- THROUGH WITH
r M FIRST AND SECOND SURFACE VINYL 3M 3630 -20 WHITE
v
Q2
COPY BACKED WITH 3/16" WHITE ACRYLIC
#7328LD
SIGN ILLUMINATED WITH DHO FLUORESCENT LAMPS
EXISTING 5" STEEL PIPE
(5.563" O.D.)
ODOODO =1= OODOOO EXISTING BRICK BASE
000000 000000
000000 000000
000000 F 1=1 000000
000000 000000
000000 000000
000000 000000
IMPROVEMENT FOR EXISTING D F FREESTANDING I N 32 SO. FT. COLOR KEY
❑ 3M 3630 -156 VIVID GREEN
(1) REQUIRED ■ SATIN FINISH BLACK
F1 EXISTING CONDITIONS
pw
PHOTO SHOWS PROPOSED SIGNAGE. SCALE: 3/16 " =1' -0"
1'
END VIEW
EXISTING LANDSCAPING
TO REMAIN
ELECTRICAL 120V
I HAVE CAREFULLY REVIEWED AND HEREBY ACCEPT
THE DRAWING(S) AS SHOWN. I REALIZETHATANY
CHANGES TO THESE DESIGNS MADE BEFORE OR
AFTER PRODUCTION MAY ALTER THE CONTRACT
PRICE. ALL CHANGES MUST BE IN WRITING AND
APPROVED BY BOTH PARTIES PRIOR TO PRODUCTION.
SIGNATURE& DATE
THE CUSTOM ARTWORK DEPICTED HEREIN IS
FOR REPRESENTATIONAL PURPOSES ONLY
AND MAY NOT EXACTLY MATCH THE COLORS
OF THE MATERIALS PROPOSED FOR USAGE.
ELECTRIC SIGNS PRODUCED AT
IMAGE WORKS CONFORM TO UL 48
L STANDARDS AND DISPLAYTHE
UNDERWRITERS LABORATORIES LABEL.
ALL ONSITE PRIMARY ELECTRICAL CONNECTIONS BY OTHERS.
DATE REVISION DESCRIPTION DESIGNER
12.15.09 REVISE CABINET DIMENSIONS WAM
1.4.10 1 REVISE CABINET DIMENSIONS WAM
2.25.101 REVISE SIGN - REMOVE TRIM WAM
11046 LEADBETTER ROAD ASHLAND VIRGINIA 23005
PHONE 804.798.5533 FAX 804.798.5582
UNION FIRST MARKET BANK
DRAWING IDENTIFICATION
CLIENT
CHARLOTTESVILLE, VA
LOCATION
KARL UFTRING
SALE REPRESENTATIVE
WAM
DESIGNER
9.23.09
DATE PREPARED
3/8 " =1'-0"
SCALE
UFMB -0001 CHA -01
PROJECTID
DRAWING IDENTIFICATION
NI
Li a
- - - - - - - - - - - - - - -
SQ. FT. CALCULATION
- - - - - - - - - - - - - -
NI
FACE -LIT INTERNALLY ILLUMINATED CHANNEL LETTERS - REMOTE POWER SUPPLIES 25.1 SQUARE FEET
(1) REQUIRED
LETTER CONSTRUCTION
BACKS:.040" WHITE / WHITE ALUMINUM
BAFFLE: N/A
RETURNS: 5" DEEP, .040" SATIN FINISH WHITE
TRIM CAP: 1" BLACK
RETAINER: N/A
SELF - CONTAINED: N/A
REMOTE: YES
RACEWAY: N/A
FACE DETAILS
PLEX: 3/16" TRANSLUCENT WHITE #2447 LID
LEXAN: N/A
FIRST SURFACE VINYLS: YES, GREEN - POLYGONS
DUAL COLOR FILM -'UNION'
ILLUMINATION
LED: WSB SHORT WHITE - HIGH POPULATION
VOLTAGE: 120V
COLOR KEY
❑ SATIN FINISH WHITE
■ 3M 3630 -156 VIVID GREEN
3M 3635 -222 DUAL COLOR FILM
REQUIREMENTS FOR ELECTRICAL ILLUMINATION
PRIMARY ELECTRICAL LOCATION IS PROVIDED
BY OTHERS. A DEDICATED CIRCUIT WITH NO SHARED
NEUTRALS AND A GROUND RETURNING TO THE PANEL
IS REQUIRED FOR ALL INSTALLATIONS
REQUIRED BY UL STANDARD #2161 AND IMAGE WORKS,
ALL TRANSFORMERS SHALL BE (GFI) GROUND
FAULT INTERRUPTED TRANSFORMERS
ALL SIGNS HAVE:
- DEDICATED BRANCH CIRCUITS
-THREE WIRES: LINE, NEUTRAL & GROUND
-WIRE SIZE: MINIMUM 12 GAUGE THIN COPPER
ALSO NOTE; GAUGE OF COPPER IS DETERMINED BY THE
LENGTH OF RUN & AMPERAGE AS PER NEC ARTICLE 300.
- GROUND WIRE MUST BE CONTINUOUS AND GO FROM
THE SIGN TO THE PANEL BOARD GROUND BUS
- VOLTAGE SHOULD READ NO MORE THAN (3) VOLTS
BETWEEN GROUND AND NEUTRAL
- CONDUIT CAN NOT BE USED AS A GROUND PATH.
W2 EXISTING CONDITIONS
.040" ALUMINUM RETURNS,
SATIN
#8 PAP
1" TRIf
BLACK
LED M
WSB:
LIQUIE
CONN
3/16" V
ACRYP
.050" P
3/8" FF
1/4" W
OF LE
1 5"
I
PFCL WITH LED ILLUMINATION, REMOTE POWER SUPPLY
NOT TO SCALE
THE LEVEL OF ILLUMINATION BY THE LED LIGHTS
WILL NOT EXCEED THE ILLUMINATION PRODUCED
BY A SINGLE STROKE OF 30 mA NEON
PHOTO SHOWS PROPOSED SIGNAGE. NOT TO SCALE.
120V
VERIFY VOLTAGE / ELECTRICAL INFO
PRIOR TO PRODUCTION
I HAVE CAREFULLY REVIEWED AND HEREBY ACCEPT
THE DRAWING(S) AS SHOWN. I REALIZE THAT ANY
CHANGES TO THESE DESIGNS MADE BEFORE OR
AFTER PRODUCTION MAY ALTER THE CONTRACT
PRICE. ALL CHANGES MUST BE IN WRITING AND
APPROVED BY BOTH PARTIES PRIOR TO PRODUCTION.
SIGNATURE & DATE
THE CUSTOM ARTWORK DEPICTED HEREIN IS
FOR REPRESENTATIONAL PURPOSES ONLY
AND MAY NOT EXACTLY MATCH THE COLORS
OF THE MATERIALS PROPOSED FOR USAGE.
ELECTRIC SIGNS PRODUCED AT
IMAGE WORKS CONFORM TO UL 48
o L STANDARDS AND DISPLAY THE
UNDERWRITERS LABORATORIES LABEL.
ALL ONSITE PRIMARY ELECTRICAL CONNECTIONS BY OTHERS.
DATE REVISION DESCRIPTION DESIGNER
11046 LEADBETTER ROAD ASHLAND VIRGINIA 23005
PHONE 804.798.5533 FAX 804.798.5582
UNION FIRST MARKET BANK
SCALE
UFMB -0001 CHA -01
PROJECT ID
DRAWING IDENTIFICATION
CLIENT
CHARLOTTESVILLE VA
LOCATION
KARL UFTRING
SALE REPRESENTATIVE
WAM
DESIGNER
11.12.09
DATE PREPARED
SCALE
UFMB -0001 CHA -01
PROJECT ID
DRAWING IDENTIFICATION
N
N
N
i
i
i
- - - - - - - - - - - - - - -
SQ. FT. CALCULATION
FACE -LIT INTERNALLY ILLUMINATED CHANNEL LETTERS - REMOTE POWER SUPPLIES 8.2 SQUARE FEET
(1) REQUIRED
LETTER CONSTRUCTION
BACKS:.040" WHITE / WHITE ALUMINUM
BAFFLE: N/A
RETURNS: 5" DEEP, .040" SATIN FINISH WHITE
TRIM CAP: 1" BLACK
RETAINER: N/A
SELF - CONTAINED: N/A
REMOTE: YES
RACEWAY: N/A
FACE DETAILS
PLEX: 3/16" TRANSLUCENT WHITE #2447 LID
LEXAN: N/A
FIRST SURFACE VINYLS: YES, GREEN - POLYGONS
DUAL COLOR FILM -'UNION'
ILLUMINATION
LED: WSB SHORT WHITE - HIGH POPULATION
VOLTAGE: 120V
COLOR KEY
❑ SATIN FINISH WHITE
■ 3M 3630 -156 VIVID GREEN
3M 3635 -222 DUAL COLOR FILM
REQUIREMENTS FOR ELECTRICAL ILLUMINATION
PRIMARY ELECTRICAL LOCATION IS PROVIDED
BY OTHERS. A DEDICATED CIRCUIT WITH NO SHARED
NEUTRALS AND A GROUND RETURNING TO THE PANEL
IS REQUIRED FOR ALL INSTALLATIONS
REQUIRED BY UL STANDARD #2161 AND IMAGE WORKS,
ALL TRANSFORMERS SHALL BE (GFI) GROUND
FAULT INTERRUPTED TRANSFORMERS
ALL SIGNS HAVE:
- DEDICATED BRANCH CIRCUITS
-THREE WIRES: LINE, NEUTRAL & GROUND
-WIRE SIZE: MINIMUM 12 GAUGE THN COPPER
ALSO NOTE; GAUGE OF COPPER IS DETERMINED BY THE
LENGTH OF RUN & AMPERAGE AS PER NEC ARTICLE 300.
- GROUND WIRE MUST BE CONTINUOUS AND GO FROM
THE SIGN TO THE PANEL BOARD GROUND BUS
- VOLTAGE SHOULD READ NO MORE THAN (3) VOLTS
BETWEEN GROUND AND NEUTRAL
- CONDUIT CAN NOT BE USED AS A GROUND PATH.
W7 EXISTING CONDITIONS
.040" ALUMINUM RETURNS,
SATIN
#8 PAP
1" TRIf
BLACK
LED M
WSB:
LIQUIE
CONN
3/16" V
ACRYP
.050" P
3/8" FF
1/4" W
OF LE
1 5"
I
PFCL WITH LED ILLUMINATION, REMOTE POWER SUPPLY
NOT TO SCALE
THE LEVEL OF ILLUMINATION BY THE LED LIGHTS
WILL NOT EXCEED THE ILLUMINATION PRODUCED
BY A SINGLE STROKE OF 30 mA NEON
PHOTO SHOWS PROPOSED SIGNAGE. NOT TO SCALE.
120V
VERIFY VOLTAGE / ELECTRICAL INFO
PRIOR TO PRODUCTION
I HAVE CAREFULLY REVIEWED AND HEREBY ACCEPT
THE DRAWING(S) AS SHOWN. I REALIZE THAT ANY
CHANGES TO THESE DESIGNS MADE BEFORE OR
AFTER PRODUCTION MAY ALTER THE CONTRACT
PRICE. ALL CHANGES MUST BE IN WRITING AND
APPROVED BY BOTH PARTIES PRIOR TO PRODUCTION.
SIGNATURE & DATE
THE CUSTOM ARTWORK DEPICTED HEREIN IS
FOR REPRESENTATIONAL PURPOSES ONLY
AND MAY NOT EXACTLY MATCH THE COLORS
OF THE MATERIALS PROPOSED FOR USAGE.
ELECTRIC SIGNS PRODUCED AT
IMAGE WORKS CONFORM TO UL 48
o L STANDARDS AND DISPLAY THE
UNDERWRITERS LABORATORIES LABEL.
ALL ONSITE PRIMARY ELECTRICAL CONNECTIONS BY OTHERS.
DATE REVISION DESCRIPTION DESIGNER
11046 LEADBETTER ROAD ASHLAND VIRGINIA 23005
PHONE 804.798.5533 FAX 804.798.5582
UNION FIRST MARKET BANK
SCALE
UFMB -0001 CHA -01
PROJECT ID
DRAWING IDENTIFICATION
CLIENT
CHARLOTTESVILLE VA
LOCATION
KARL UFTRING
SALE REPRESENTATIVE
WAM
DESIGNER
11.12.09
DATE PREPARED
SCALE
UFMB -0001 CHA -01
PROJECT ID
DRAWING IDENTIFICATION
O
N
O °
r
3' -9 "
NON - ILLUMINATED AWNING .57 SO. FT. COPY AREA
RE -COVER EXISTING AWNING FRAME.
AWNING MATERIAL TO BE SUNBRELLA BLACK #4608 -0000 WITH
FIRST SURFACE VINYL COPY
(1) REQUIRED
COLOR KEY
■ SUNBRELLA BLACK #4608 -0000
❑ 3M 7725 -10 WHITE
l%w0000
W1 EXISTING CONDITIONS
TI
PHOTO SHOWS PROPOSED SIGNAGE. NOT TO SCALE.
END VIEW
I HAVE CAREFULLY REVIEWED AND HEREBY ACCEPT
THE DRAWING(S) AS SHOWN. I REALIZETHATANY
CHANGES TO THESE DESIGNS MADE BEFORE OR
AFTER PRODUCTION MAY ALTER THE CONTRACT
PRICE. ALL CHANGES MUST BE IN WRITING AND
APPROVED BY BOTH PARTIES PRIOR TO PRODUCTION.
SIGNATURE& DATE
THE CUSTOM ARTWORK DEPICTED HEREIN IS
FOR REPRESENTATIONAL PURPOSES ONLY
AND MAY NOT EXACTLY MATCH THE COLORS
OF THE MATERIALS PROPOSED FOR USAGE.
ELECTRIC SIGNS PRODUCED AT
IMAGE WORKS CONFORM TO UL 48
L STANDARDS AND DISPLAYTHE
UNDERWRITERS LABORATORIES LABEL.
ALL ONSITE PRIMARY ELECTRICAL CONNECTIONS BY OTHERS.
DATE REVISION DESCRIPTION DESIGNER
11046 LEADBETTER ROAD ASHLAND VIRGINIA 23005
PHONE 804.798.5533 FAX 804.798.5582
UNION FIRST MARKET BANK
DRAWING IDENTIFICATION
CLIENT
CHARLOTTESVILLE, VA
LOCATION
KARL UFTRING
SALE REPRESENTATIVE
WAM
DESIGNER
9.23.09
DATE PREPARED
1 ..=1' -0"
SCALE
UFMB -0001 CHA -01
PROJECTID
AWN R2
DRAWING IDENTIFICATION
PHOTO OF FRONT ELEVATION SHOWS PROPOSED SIGNAGE 3/8 " =1' -0"
I HAVE CAREFULLY REVIEWED AND HEREBY ACCEPT
THE DRAWING(S) AS SHOWN. I REALIZETHATANY
CHANGES TO THESE DESIGNS MADE BEFORE OR
AFTER PRODUCTION MAY ALTER THE CONTRACT
PRICE. ALL CHANGES MUST BE IN WRITING AND
APPROVED BY BOTH PARTIES PRIOR TO PRODUCTION.
SIGNATURE& DATE
THE CUSTOM ARTWORK DEPICTED HEREIN IS
FOR REPRESENTATIONAL PURPOSES ONLY
AND MAY NOT EXACTLY MATCH THE COLORS
OF THE MATERIALS PROPOSED FOR USAGE.
ELECTRIC SIGNS PRODUCED AT
IMAGE WORKS CONFORM TO UL 48
L STANDARDS AND DISPLAYTHE
UNDERWRITERS LABORATORIES LABEL.
ALL ONSITE PRIMARY ELECTRICAL CONNECTIONS BY OTHERS.
DATE REVISION DESCRIPTION DESIGNER
11046 LEADBETTER ROAD ASHLAND VIRGINIA 23005
PHONE 804.798.5533 FAX 804.798.5582
UNION FIRST MARKET BANK
CLIENT
CHARLOTTESVILLE, VA
LOCATION
KARL UFTRING
SALE REPRESENTATIVE
WAM
DESIGNER
9.23.09
DATE PREPARED
3/8 " =1' -0"
SCALE
UFMB -0001 CHA -01
PROJECTID
DRAWING IDENTIFICATION
ir
■ a I: *L- -
Ar C.0
_ •
J.
rif
I
Y T
1
- a �
ryp' L •ti`
lmih
PHOTO OF SIDE ELEVATION SHOWS PROPOSED SIGNAGE
1/4 " =1' -0"
I HAVE CAREFULLY REVIEWED AND HEREBY ACCEPT
THE DRAWING(S) AS SHOWN. I REALIZETHATANY
CHANGES TO THESE DESIGNS MADE BEFORE OR
AFTER PRODUCTION MAY ALTER THE CONTRACT
PRICE. ALL CHANGES MUST BE IN WRITING AND
APPROVED BY BOTH PARTIES PRIOR TO PRODUCTION.
SIGNATURE& DATE
THE CUSTOM ARTWORK DEPICTED HEREIN IS
FOR REPRESENTATIONAL PURPOSES ONLY
AND MAY NOT EXACTLY MATCH THE COLORS
OF THE MATERIALS PROPOSED FOR USAGE.
ELECTRIC SIGNS PRODUCED AT
IMAGE WORKS CONFORM TO UL 48
U� STANDARDS AND DISPLAYTHE
UNDERWRITERS LABORATORIES LABEL.
ALL ONSITE PRIMARY ELECTRICAL CONNECTIONS BY OTHERS.
DATE REVISION DESCRIPTION DESIGNER
11046 LEADBETTER ROAD ASHLAND VIRGINIA 23005
PHONE 804.798.5533 FAX 804.798.5582
UNION FIRST MARKET BANK
CLIENT
CHARLOTTESVILLE. VA
' LOCATION
KARL UFTRING
SALE REPRESENTATIVE
WAM
!' DESIGNER
2.25.10
DATE PREPARED
1/4 " =1' -0"
SCALE
UFMB -0001 CHA -01
PROJECTID
ELE 2
DRAWING IDENTIFICATION