HomeMy WebLinkAboutARB201100138 Legacy Document 2012-03-12H
r �
I
FIRST SURFACE BLUE VINYL TO
HAVE UNDER LAYER OF OPAQUE VINYL;
BLUE VINYL WILL NOT BE ILLUMINATED.
W TO ILLUMINATE WHITE.
9'-4"
- 'SWOOSH' NON - ILLUMINATED
125" ALUMINUM 'SHADOW' PANEL
lA 00
N N
FACE -LIT INTERNALLY ILLUMINATED CHANNEL LETTERS 30.3 SQ. FT.
(1) OF (2) REQUIRED
LETTER CONSTRUCTION
BACKS:.040" WHITE / WHITE ALUMINUM
BAFFLE: N/A
RETURNS: 5" DEEP, .040" ALUMINUM, PAINTED
SATIN FINISH WHITE ('TELOS &'WIRELESS')
TRIM CAP: 1" WHITE ('TELOS' &'WIRELESS')
1" BLUE ('N'& SWOOSH')
RETAINER: N/A
SELF - CONTAINED: N/A
REMOTE: N/A
RACEWAY: 8 "x8" RACEWAY,
PAINTED SATIN FINISH BLACK
FACE DETAILS
PLEX: 3/16" ACRYLITE 048 -2GP (PLEXI W -7420)
LEXAN: N/A
FIRST SURFACE VINYLS: YES, TRIANGLE TO HAVE
FIRST SURFACE VINYL 3M 3630 -157 SULTAN BLUE,
REVERSE CUT'N' TO REMAIN WHITE
ILLUMINATION
LED: WHITE LED
NEON: N/A
TRANSFORMERS: SLOAN 60W
MILLIAMPS: 30
VOLTAGE: 120V
REQUIREMENTS FOR ELECTRICAL ILLUMINATION
PRIMARY ELECTRICAL LOCATION IS PROVIDED
BY OTHERS. A DEDICATED CIRCUIT WITH NO SHARED
NEUTRALS AND A GROUND RETURNING TO THE PANEL
IS REQUIRED FOR ALL INSTALLATIONS
REQUIRED BY UL STANDARD #2161 AND IMAGE WORKS,
ALL TRANSFORMERS SHALL BE (GFI) GROUND
FAULT INTERRUPTED TRANSFORMERS
ALL SIGNS HAVE:
- DEDICATED BRANCH CIRCUITS
-THREE WIRES: LINE, NEUTRAL & GROUND
-WIRE SIZE: MINIMUM 12 GAUGE THN COPPER
ALSO NOTE; GAUGE OF COPPER IS DETERMINED BY THE
LENGTH OF RUN & AMPERAGE AS PER NEC ARTICLE 300.
- GROUND WIRE MUST BE CONTINUOUS AND GO FROM
THE SIGN TO THE PANEL BOARD GROUND BUS
- VOLTAGE SHOULD READ NO MORE THAN (3) VOLTS
BETWEEN GROUND AND NEUTRAL
- CONDUIT CAN NOT BE USED AS A GROUND PATH.
NOTE: THE LEVEL OF ILLUMINATION
PROVIDED BY THE LED LIGHTS WILL
NOT EXCEED THE ILLUMINATION
PRODUCED BY A SINGLE STROKE OF
30Ma NEON
COLOR KEY
PAINT
■ PMS 287C BLUE
■ SATIN FINISH BLACK
ElSATIN FINISH WHITE
RACEWAY PAINTED TO MATCH WALL (T.B.D.)
VINYL
■ 3M 3630 -157 SULTAN BLUE
■ 3M 3630 -22 BLACK (BLOCK -OUT)
28' -7" +/-
LEASE
END VIEW
WEST ELEVATION BLDG. G SHOWS PROPOSED SIGNAGE 1/16 " =1' -0"
I HAVE CAREFULLY REVIEWED AND HEREBY ACCEPI
THE DRAWING(S) AS SHOWN. I REALIZE THAT AN)
CHANGES TO THESE DESIGNS MADE BEFORE OR
AFTER PRODUCTION MAY ALTER THE CONTRACT
PRICE. ALL CHANGES MUST BE IN WRITING AND
APPROVED BY BOTH PARTIES PRIOR TO PRODUCTIOI
SIGNATURE & DATE
THE CUSTOM ARTWORK DEPICTED HEREIN IS
FOR REPRESENTATIONAL PURPOSES ONLY
AND MAY NOT EXACTLY MATCH THE COLORS
OF THE MATERIALS PROPOSED FOR USAGE.
9 ELECTRIC SIGNS PRODUCED AT
U■ IMAGE WORKS CONFORM TO UL 48
o ` STANDARDS AND DISPLAY THE
UNDERWRITERS LABORATORIES LABEL.
ALL ONSITE PRIMARY ELECTRICAL CONNECTIONS BY OTH
DATE REVISION DESCRIPTION DESIGI
11046 LEADBETTER ROAD ASHLAND, VA 23005
PHONE: 804.798.5533 FAX: 804.798.5582
NTELOS
CLIE
CHARLOTTESVILLE, VA
LOCATI,
JONATHAN DABNEY
SALES REPRESENTATI
WAM
DESIGN
9.7.11
DATE PREPARI
3/4 " =1'-0"
SCA
NTELOS - HOLLYMEAD -01
PROJECT
CL 1 R2
DRAWING IDENTIFICATIC
H
r �
I
FIRST SURFACE BLUE VINYL TO
HAVE UNDER LAYER OF OPAQUE VINYL;
BLUE VINYL WILL NOT BE ILLUMINATED.
W TO ILLUMINATE WHITE.
9'-4"
- 'SWOOSH' NON - ILLUMINATED
125" ALUMINUM 'SHADOW' PANEL
lA 00
N N
FACE -LIT INTERNALLY ILLUMINATED CHANNEL LETTERS 30.3 SQ. FT.
(2) OF (2) REQUIRED
LETTER CONSTRUCTION
BACKS:.040" WHITE / WHITE ALUMINUM
BAFFLE: N/A
RETURNS: 5" DEEP, .040" ALUMINUM, PAINTED
SATIN FINISH WHITE ('TELOS &'WIRELESS')
TRIM CAP: 1" WHITE ('TELOS' &'WIRELESS')
1" BLUE ('N'& SWOOSH')
RETAINER: N/A
SELF - CONTAINED: N/A
REMOTE: N/A
RACEWAY: 8 "x8" RACEWAY,
PAINTED SATIN FINISH BLACK
FACE DETAILS
PLEX: 3/16" ACRYLITE 048 -2GP (PLEXI W -7420)
LEXAN: N/A
FIRST SURFACE VINYLS: YES, TRIANGLE TO HAVE
FIRST SURFACE VINYL 3M 3630 -157 SULTAN BLUE,
REVERSE CUT'N' TO REMAIN WHITE
ILLUMINATION
LED: WHITE LED
NEON: N/A
TRANSFORMERS: SLOAN 60W
MILLIAMPS: 30
VOLTAGE: 120V
28' -7" +/-
LEASE
REQUIREMENTS FOR ELECTRICAL ILLUMINATION
PRIMARY ELECTRICAL LOCATION IS PROVIDED
BY OTHERS. A DEDICATED CIRCUIT WITH NO SHARED
NEUTRALS AND A GROUND RETURNING TO THE PANEL
IS REQUIRED FOR ALL INSTALLATIONS
REQUIRED BY UL STANDARD #2161 AND IMAGE WORKS,
ALL TRANSFORMERS SHALL BE (GFI) GROUND
FAULT INTERRUPTED TRANSFORMERS
ALL SIGNS HAVE:
- DEDICATED BRANCH CIRCUITS
-THREE WIRES: LINE, NEUTRAL & GROUND
-WIRE SIZE: MINIMUM 12 GAUGE THN COPPER
ALSO NOTE; GAUGE OF COPPER IS DETERMINED BY THE
LENGTH OF RUN & AMPERAGE AS PER NEC ARTICLE 300.
- GROUND WIRE MUST BE CONTINUOUS AND GO FROM
THE SIGN TO THE PANEL BOARD GROUND BUS
- VOLTAGE SHOULD READ NO MORE THAN (3) VOLTS
BETWEEN GROUND AND NEUTRAL
- CONDUIT CAN NOT BE USED AS A GROUND PATH.
NOTE: THE LEVEL OF ILLUMINATION
PROVIDED BY THE LED LIGHTS WILL
NOT EXCEED THE ILLUMINATION
PRODUCED BY A SINGLE STROKE OF
30Ma NEON
COLOR KEY
PAINT
■ PMS 287C BLUE
■ SATIN FINISH BLACK
ElSATIN FINISH WHITE
RACEWAY PAINTED TO MATCH WALL (T.B.D.)
VINYL
■ 3M 3630 -157 SULTAN BLUE
■ 3M 3630 -22 BLACK (BLOCK -OUT)
END VIEW
EAST ELEVATION BLDG. G SHOWS PROPOSED SIGNAGE 1/16 " =1' -0"
I HAVE CAREFULLY REVIEWED AND HEREBY ACCEPT
THE DRAWING(S) AS SHOWN. I REALIZE THAT ANY
CHANGES TO THESE DESIGNS MADE BEFORE OR
AFTER PRODUCTION MAY ALTER THE CONTRACT
PRICE. ALL CHANGES MUST BE IN WRITING AND
APPROVED BY BOTH PARTIES PRIOR TO PRODUCTION.
SIGNATURE & DATE
THE CUSTOM ARTWORK DEPICTED HEREIN IS
FOR REPRESENTATIONAL PURPOSES ONLY
AND MAY NOT EXACTLY MATCH THE COLORS
OF THE MATERIALS PROPOSED FOR USAGE.
9 ELECTRIC SIGNS PRODUCED AT
U■ IMAGE WORKS CONFORM TO UL 48
o ` STANDARDS AND DISPLAY THE
UNDERWRITERS LABORATORIES LABEL.
ALL ONSITE PRIMARY ELECTRICAL CONNECTIONS BY OTHERS.
DATE REVISION DESCRIPTION DESIGNER
11046 LEADBETTER ROAD ASHLAND, VA 23005
PHONE: 804.798.5533 FAX: 804.798.5582
NTELOS
CLIENT
CHARLOTTESVILLE, VA
LOCATION
JONATHAN DABNEY
SALES REPRESENTATIVE
WAM
DESIGNER
9.7.11
DATE PREPARED
3/4 " =1'-0"
SCALE
NTELOS - HOLLYMEAD -01
PROJECF ID
CL 2 R2
DRAWING IDENTIFICATION