HomeMy WebLinkAboutARB201100138 Legacy Document 2012-03-12H r � I FIRST SURFACE BLUE VINYL TO HAVE UNDER LAYER OF OPAQUE VINYL; BLUE VINYL WILL NOT BE ILLUMINATED. W TO ILLUMINATE WHITE. 9'-4" - 'SWOOSH' NON - ILLUMINATED 125" ALUMINUM 'SHADOW' PANEL lA 00 N N FACE -LIT INTERNALLY ILLUMINATED CHANNEL LETTERS 30.3 SQ. FT. (1) OF (2) REQUIRED LETTER CONSTRUCTION BACKS:.040" WHITE / WHITE ALUMINUM BAFFLE: N/A RETURNS: 5" DEEP, .040" ALUMINUM, PAINTED SATIN FINISH WHITE ('TELOS &'WIRELESS') TRIM CAP: 1" WHITE ('TELOS' &'WIRELESS') 1" BLUE ('N'& SWOOSH') RETAINER: N/A SELF - CONTAINED: N/A REMOTE: N/A RACEWAY: 8 "x8" RACEWAY, PAINTED SATIN FINISH BLACK FACE DETAILS PLEX: 3/16" ACRYLITE 048 -2GP (PLEXI W -7420) LEXAN: N/A FIRST SURFACE VINYLS: YES, TRIANGLE TO HAVE FIRST SURFACE VINYL 3M 3630 -157 SULTAN BLUE, REVERSE CUT'N' TO REMAIN WHITE ILLUMINATION LED: WHITE LED NEON: N/A TRANSFORMERS: SLOAN 60W MILLIAMPS: 30 VOLTAGE: 120V REQUIREMENTS FOR ELECTRICAL ILLUMINATION PRIMARY ELECTRICAL LOCATION IS PROVIDED BY OTHERS. A DEDICATED CIRCUIT WITH NO SHARED NEUTRALS AND A GROUND RETURNING TO THE PANEL IS REQUIRED FOR ALL INSTALLATIONS REQUIRED BY UL STANDARD #2161 AND IMAGE WORKS, ALL TRANSFORMERS SHALL BE (GFI) GROUND FAULT INTERRUPTED TRANSFORMERS ALL SIGNS HAVE: - DEDICATED BRANCH CIRCUITS -THREE WIRES: LINE, NEUTRAL & GROUND -WIRE SIZE: MINIMUM 12 GAUGE THN COPPER ALSO NOTE; GAUGE OF COPPER IS DETERMINED BY THE LENGTH OF RUN & AMPERAGE AS PER NEC ARTICLE 300. - GROUND WIRE MUST BE CONTINUOUS AND GO FROM THE SIGN TO THE PANEL BOARD GROUND BUS - VOLTAGE SHOULD READ NO MORE THAN (3) VOLTS BETWEEN GROUND AND NEUTRAL - CONDUIT CAN NOT BE USED AS A GROUND PATH. NOTE: THE LEVEL OF ILLUMINATION PROVIDED BY THE LED LIGHTS WILL NOT EXCEED THE ILLUMINATION PRODUCED BY A SINGLE STROKE OF 30Ma NEON COLOR KEY PAINT ■ PMS 287C BLUE ■ SATIN FINISH BLACK ElSATIN FINISH WHITE RACEWAY PAINTED TO MATCH WALL (T.B.D.) VINYL ■ 3M 3630 -157 SULTAN BLUE ■ 3M 3630 -22 BLACK (BLOCK -OUT) 28' -7" +/- LEASE END VIEW WEST ELEVATION BLDG. G SHOWS PROPOSED SIGNAGE 1/16 " =1' -0" I HAVE CAREFULLY REVIEWED AND HEREBY ACCEPI THE DRAWING(S) AS SHOWN. I REALIZE THAT AN) CHANGES TO THESE DESIGNS MADE BEFORE OR AFTER PRODUCTION MAY ALTER THE CONTRACT PRICE. ALL CHANGES MUST BE IN WRITING AND APPROVED BY BOTH PARTIES PRIOR TO PRODUCTIOI SIGNATURE & DATE THE CUSTOM ARTWORK DEPICTED HEREIN IS FOR REPRESENTATIONAL PURPOSES ONLY AND MAY NOT EXACTLY MATCH THE COLORS OF THE MATERIALS PROPOSED FOR USAGE. 9 ELECTRIC SIGNS PRODUCED AT U■ IMAGE WORKS CONFORM TO UL 48 o ` STANDARDS AND DISPLAY THE UNDERWRITERS LABORATORIES LABEL. ALL ONSITE PRIMARY ELECTRICAL CONNECTIONS BY OTH DATE REVISION DESCRIPTION DESIGI 11046 LEADBETTER ROAD ASHLAND, VA 23005 PHONE: 804.798.5533 FAX: 804.798.5582 NTELOS CLIE CHARLOTTESVILLE, VA LOCATI, JONATHAN DABNEY SALES REPRESENTATI WAM DESIGN 9.7.11 DATE PREPARI 3/4 " =1'-0" SCA NTELOS - HOLLYMEAD -01 PROJECT CL 1 R2 DRAWING IDENTIFICATIC H r � I FIRST SURFACE BLUE VINYL TO HAVE UNDER LAYER OF OPAQUE VINYL; BLUE VINYL WILL NOT BE ILLUMINATED. W TO ILLUMINATE WHITE. 9'-4" - 'SWOOSH' NON - ILLUMINATED 125" ALUMINUM 'SHADOW' PANEL lA 00 N N FACE -LIT INTERNALLY ILLUMINATED CHANNEL LETTERS 30.3 SQ. FT. (2) OF (2) REQUIRED LETTER CONSTRUCTION BACKS:.040" WHITE / WHITE ALUMINUM BAFFLE: N/A RETURNS: 5" DEEP, .040" ALUMINUM, PAINTED SATIN FINISH WHITE ('TELOS &'WIRELESS') TRIM CAP: 1" WHITE ('TELOS' &'WIRELESS') 1" BLUE ('N'& SWOOSH') RETAINER: N/A SELF - CONTAINED: N/A REMOTE: N/A RACEWAY: 8 "x8" RACEWAY, PAINTED SATIN FINISH BLACK FACE DETAILS PLEX: 3/16" ACRYLITE 048 -2GP (PLEXI W -7420) LEXAN: N/A FIRST SURFACE VINYLS: YES, TRIANGLE TO HAVE FIRST SURFACE VINYL 3M 3630 -157 SULTAN BLUE, REVERSE CUT'N' TO REMAIN WHITE ILLUMINATION LED: WHITE LED NEON: N/A TRANSFORMERS: SLOAN 60W MILLIAMPS: 30 VOLTAGE: 120V 28' -7" +/- LEASE REQUIREMENTS FOR ELECTRICAL ILLUMINATION PRIMARY ELECTRICAL LOCATION IS PROVIDED BY OTHERS. A DEDICATED CIRCUIT WITH NO SHARED NEUTRALS AND A GROUND RETURNING TO THE PANEL IS REQUIRED FOR ALL INSTALLATIONS REQUIRED BY UL STANDARD #2161 AND IMAGE WORKS, ALL TRANSFORMERS SHALL BE (GFI) GROUND FAULT INTERRUPTED TRANSFORMERS ALL SIGNS HAVE: - DEDICATED BRANCH CIRCUITS -THREE WIRES: LINE, NEUTRAL & GROUND -WIRE SIZE: MINIMUM 12 GAUGE THN COPPER ALSO NOTE; GAUGE OF COPPER IS DETERMINED BY THE LENGTH OF RUN & AMPERAGE AS PER NEC ARTICLE 300. - GROUND WIRE MUST BE CONTINUOUS AND GO FROM THE SIGN TO THE PANEL BOARD GROUND BUS - VOLTAGE SHOULD READ NO MORE THAN (3) VOLTS BETWEEN GROUND AND NEUTRAL - CONDUIT CAN NOT BE USED AS A GROUND PATH. NOTE: THE LEVEL OF ILLUMINATION PROVIDED BY THE LED LIGHTS WILL NOT EXCEED THE ILLUMINATION PRODUCED BY A SINGLE STROKE OF 30Ma NEON COLOR KEY PAINT ■ PMS 287C BLUE ■ SATIN FINISH BLACK ElSATIN FINISH WHITE RACEWAY PAINTED TO MATCH WALL (T.B.D.) VINYL ■ 3M 3630 -157 SULTAN BLUE ■ 3M 3630 -22 BLACK (BLOCK -OUT) END VIEW EAST ELEVATION BLDG. G SHOWS PROPOSED SIGNAGE 1/16 " =1' -0" I HAVE CAREFULLY REVIEWED AND HEREBY ACCEPT THE DRAWING(S) AS SHOWN. I REALIZE THAT ANY CHANGES TO THESE DESIGNS MADE BEFORE OR AFTER PRODUCTION MAY ALTER THE CONTRACT PRICE. ALL CHANGES MUST BE IN WRITING AND APPROVED BY BOTH PARTIES PRIOR TO PRODUCTION. SIGNATURE & DATE THE CUSTOM ARTWORK DEPICTED HEREIN IS FOR REPRESENTATIONAL PURPOSES ONLY AND MAY NOT EXACTLY MATCH THE COLORS OF THE MATERIALS PROPOSED FOR USAGE. 9 ELECTRIC SIGNS PRODUCED AT U■ IMAGE WORKS CONFORM TO UL 48 o ` STANDARDS AND DISPLAY THE UNDERWRITERS LABORATORIES LABEL. ALL ONSITE PRIMARY ELECTRICAL CONNECTIONS BY OTHERS. DATE REVISION DESCRIPTION DESIGNER 11046 LEADBETTER ROAD ASHLAND, VA 23005 PHONE: 804.798.5533 FAX: 804.798.5582 NTELOS CLIENT CHARLOTTESVILLE, VA LOCATION JONATHAN DABNEY SALES REPRESENTATIVE WAM DESIGNER 9.7.11 DATE PREPARED 3/4 " =1'-0" SCALE NTELOS - HOLLYMEAD -01 PROJECF ID CL 2 R2 DRAWING IDENTIFICATION