Loading...
HomeMy WebLinkAboutARB201400029 Review Comments Initial Site Plan 2014-04-15ARCHITECTURAL REVIEW BOARD STAFF REPORT Project #/Name ARB- 2014 -29 and ARB 2014 -39: Goodwill Millcreek Review Type Initial Site Plan and Preliminary Architectural Review Parcel Identification 077000000047AO Location At the northeast corner of the intersection of Avon Street Extended with Mill Creek Drive Zoned Planned Development Shopping Center (PDSC), Entrance Corridor (EC) Owner /Applicant Blakeley T or Jennifer Parham Greenhalgh/Balzer & Assoc. (Kent O'Donahue) and Bob Pingry Magisterial District Scottsville Proposal To construct a 10,400 sf commercial building with associated parking on an outparcel in the South Side Shopping Center development. Context The immediate context of the site is the South Side Shopping Center, a brick building with a Food Lion grocery store as its major tenant. To the south across Mill Creek Drive is a convenience store with fuel pump canopy and car wash, and a bank. Further to the east is a high school and fire station. Across Avon Street to the west is the Mill Creek residential development. Visibility The north, south and west elevations of the proposed building will be readily visible from the Entrance Corridor, but the lower parts of the walls will be hidden by the slope of the land along Avon Street and Mill Creek Drive. ARB Meeting Date April 21, 2014 Staff Contact Margaret Maliszewski PROJECT HISTORY DATE APPLICATION /REVIEW TYPE RESULT April 17, 1998 ARB- 1997 -32: Southside Shopping Center Certificate of Appropriateness granted for the main shopping center building at this site. Various Various Numerous sign applications have been reviewed and approved for tenants in this shopping center. ANALYSIS Gray highlight = guideline can't be reviewed at initial site plan stage, can provide recommendations for final Yellow highlight = can only review for location/configuration at initial site plan Regular text = guideline can be reviewed at initial site plan stage, can make condition of initial plan approval, can be basis for denial REF GUIDELINE ISSUE RECOMMENDATION 1 The goal of the regulation of the design of development The applicant proposes a brick- faced, Indicate on the drawings within the designated Entrance Corridors is to insure that nearly square building with a customer the material and color new development within the corridors reflects the entrance on the south side and a donation intended for the back of the traditional architecture of the area. Therefore, it is the drop -off point on the west side, both pedimented entrance purpose of ARB review and of these Guidelines, that marked by pedimented pavilions projecting features. Choose a material proposed development within the designated Entrance from the main walls of the building. The and color that is integrated Corridors reflect elements of design characteristic of the pavilions have blue metal roofs to with the overall building. si�nt historical landmarks, buildings, and structures coordinate with the existing shopping of the Charlottesville and Albemarle area, and to promote center. The pediments rising above the Revise the site plan to show orderly and attractive development within these corridors. main roofline add visual interest and the the entrance pavilion. Applicants should note that replication of historic structures depth of the entrance features gives them a is neither required nor desired. more architectural appearance than a simple raised parapet would. The material Confirm that the lighter color horizontal courses 3 New structures and substantial additions to existing structures should respect the traditions of the architecture proposed for the back of the pedimented shown in the color of historically significant buildings in the Charlottesville form isn't clear from the drawings. The renderings are a lighter and Albemarle area. Photographs of historic buildings in form of the pavilion at the main entrance color brick, as is seen in the the area, as well as drawings of architectural features, isn't clear on the site plan. existing shopping center. which provide important examples of this tradition are Identify the material and contained in Appendix A. The length of each elevation of the building is broken down into bays by brick color on the drawings. 4 The examples contained in Appendix A should be used as a guide for building design: the standard of compatibility pilasters. A course of (what appears to be) with the area's historic structures is not intended to impose lighter colored brick located above the a rigid design solution for new development. Replication of pilasters divides the height of the walls. the design of the important historic sites in the area is Above the brick course, simple brick neither intended nor desired. The Guideline's standard of detailing is added above each pilaster, and compatibility can be met through building scale, materials, a brick cornice tops the wall. Between and forms which may be embodied in architecture which it pilasters, bays on the south and west contemporary as well as traditional. The Guidelines allow elevations are treated with storefront individuality in design to accommodate varying tastes as windows (the two easternmost bays on the well as special functional requirements. south elevation), transom windows (the southernmost bay of the west elevation and 5 It is also an important objective of the Guidelines to establish a pattern of compatible architectural the western bays of the south elevation), or characteristics throughout the Entrance Corridor in order to brick detailing (two middle bays on the achieve unity and coherence. Building designs should west elevation). The transom windows are demonstrate sensitivity to other nearby structures within the expected to have some visibility from the Entrance Corridor. Where a designated corridor is EC. substantially developed, these Guidelines require striking a careful balance between harmonizing new development Bays on the north elevation have no with the existing character of the corridor and achieving additional treatment. The perspective compatibility with the significant historic sites in the area. views and elevations show an L- shaped brick wall at the middle of the north 9 Building forms and features, including roofs, windows, doors, materials, colors and textures should be compatible elevation. The wall forms a screen for the with the forms and features of the significant historic compactor located in this area. buildings in the area, exemplified by (but not limited to) t1i buildings described in Appendix A [of the design The brick and blue metal materials, the guidelines]. The standard of compatibility can be met division of the walls into bays, the piers through scale, materials, and forms which may be and pilasters, and the cornice detailing all embodied in architecture which is contemporary as well as relate generally to the historic buildings of traditional. The replication of important historic sites in the County and directly to the existing Albemarle County is not the objective of these guidelines. South Side Shopping Center building. 10 Buildings should relate to their site and the surrounding context of buildings. 11 The overall design of buildings should have human scale. The brick material and detailing, pilasters, Adjust the brick detailing to Scale should be integral to the building and site design. piers, and canopies help establish human scale. The lighter brick course above the eliminate the top -heavy appearance of the walls. 12 Architecture proposed within the Entrance Corridor shoul use forms, shapes, scale, and materials to create a cohesivd pilasters divides the walls horizontally. whole. The resulting proportions give the building a top-heavy appearance. 13 Any appearance of "blankness" resulting from building Significant portions of the walls are See recommendations at design should be relieved using design detail or vegetation] without doors and storefront windows. guidelines 17, 18, 19. or both. Pilasters, brick detailing and transoms are used to help relieve the blankness. This treatment is generally acceptable in this case, given that the lower wall areas will be screened by the topography of the site. However, the north elevation has the least amount of detail and includes a service area. Additional treatments might be needed to mitigate the appearance of this elevation, based on the degree of visibility. 14 Arcades, colonnades, or other architectural connecting Materials and details are used to visually None. devices should be used to unify groups of buildings within connect the proposed building to the a development. existing bu Iding on site. 15 Trademark buildings and related features should be The proposed design is not a company None. modified to meet the requirements of the Guidelines. standard. 16 Window glass in the Entrance Corridors should not be highl Details on window glass have not yet been Provide on the plan window tinted or highly reflective. Window glass in the Entrance provided. glass details indicating that Corridors should meet the following criteria: Visible light visible light transmittance transmittance (VLT) shall not drop below 4001o. Visible (VLT) shall not drop below light reflectance (VLR) shall not exceed 30 %. 40% and visible light Specifications on the proposed window glass should be reflectance (VLR) shall not submitted with the application for final review. exceed 30 %. Li htin 22 Light should be contained on the site and not spill over A basic lighting plan has been provided. It Revise the maintenance onto adjacent properties or streets; shows that spillover does not exceed .5 fc along Avon and Mill Creek, but the wrong factor (LLF) to 1.0 for all proposed light fixtures and 24 Light levels exceeding 30 footcandles are not appropriate for display lots in the Entrance Corridors. Lower light maintenance factor was used and the recalculate the levels will apply to most other uses in the Entrance intensity of illumination cannot be photometrics. Provide a Corridors. determined from the contour line style of point -by -point grid style lighting plan that was submitted. A point- photometric plan for by-point id is needed. review. 23 Light should be shielded, recessed or flush - mounted t4 Cut sheets for the light fixtures are not Provide cut sheets for the eliminate glare. All fixtures with lamps emitting 3000 included in the plan. proposed light fixtures in lumens or more must be full cutoff fixtures. the site plan. 25 Light should have the appearance of white light with a Metal halide lamps are proposed. Confirm that the proposed warm soft glow; however, a consistent appearance lamp type matches that throughout a site or development is required. Consequently, which is currently used in if existing lamps that emit non -white light are to remain, the shopping center. new lamps may be required to match them. 26 Dark brown, dark bronze, or black are appropriate colors Fixture and pole colors have not been Identify the fixture and pole for free - standing pole mounted light fixtures in the addressed. colors in the light schedule Entrance Corridors. or with a note on the lighting plan. Bronze is recommended. 27 The height and scale of freestanding, pole- mounted light Pole height is indicated as 17.5'. Bases are None. fixtures should be compatible with the height and scale of not indicated, but if standard bases are the buildings and the sites they are illuminating, and with proposed, this height will still appear the use of the site. Typically, the height of freestanding coordinated with the building. pole - mounted light fixtures in the Entrance Corridors should not exceed 20 feet, including the base. Fixtures that exceed 20 feet in height will typically require additional screening to achieve an appropriate appearance from the Entrance Corridor. 28 In determining the appropriateness of lighting fixtures for the Entrance Corridors, the individual context of the site will be taken into consideration on a case by case basis. 29 The following note should be included on the lighting plan: The note does not appear on the plan. Include the standard "Each outdoor luminaire equipped with a lamp that emits lighting note on the plan. 3,000 or more initial lumens shall be a full cutoff luminaire and shall be arranged or shielded to reflect light away from adjoining residential districts and away from adjacent roads. The spillover of lighting from luminaires onto public roads and property in residential or rural areas zoning districts shall not exceed one half footcandle." Landscaping 7 The requirements of the Guidelines regarding landscaping Trees and shrubs exist along the Avon Show on the plan the are intended to reflect the landscaping characteristic of frontage, although the shrubs are not shrubs that exist along many of the area's significant historic sites which is shown on the plan. The trees act as EC Avon and Mill Creek. characterized by large shade trees and lawns. Landscaping frontage trees, although they've been Show the existing trees and should promote visual order within the Entrance Corridor planted in the right -of -way and under a shrubs that are to remain and help to integrate buildings into the existing power line. The trees on Avon are, for the with accurate drip lines. environment of the corridor. most part, large trees spaced 35' on center. Interspersed ornamentals do not exist along Move the new telephone 8 Continuity within the Entrance Corridor s ou d be obtaine4 by planting different types of plant materials that share Avon Street. and power lines outside of similar characteristics. Such common elements allow for planting areas. more flexibility in the design of structures because Three Zelkova trees are proposed to be common landscape features will help to harmonize the added on the Avon Street side of the site, Provide interspersed appearance of development as seen from the street upon at parking lot level. A group of boxwoods ornamental trees on site, which the Corridor is centered. is proposed near each tree. along Avon Street. Provide additional 32 Landscaping along the frontage of Entrance Corridor streets should include the following: Utility lines are proposed to be run along landscaping on site, outside a. Large shade trees should be planted parallel to the the Avon Street side of the site, between of utilities, to help better Entrance Corridor Street. Such trees should be at least 3'/2 the parking lot and the property line. This integrate the building and inches caliper (measured 6 inches above the ground) and limits the ability to plant additional trees in its service areas into the should be of a plant species common to the area. Such trees this area. corridor. should be located at least every 35 feet on center. b. Flowering ornamental trees of a species common to the area should be interspersed among the trees required by the preceding paragraph. The ornamental trees need not alternate one for one with the large shade trees. They may be planted among the large shade trees in a less regular spacing pattern. c. In situations where appropriate, a three or four board fence or low stone wall, typical of the area, should align the frontage of the Entrance Corridor street. d. An area of sufficient width to accommodate the foregoing plantings and fencing should be reserved parallel to the Entrance Corridor street, and exclusive of road right- of-way and utility easements. 33 Landscaping along interior roads: Trees and shrubs exist along the Mill Show on the plan the a. Large trees should be planted parallel to all interior Creek frontage, although they are not existing shrubs along Mill roads. Such trees should be at least 2'h inches caliper provided consistently and the shrubs are Creek Drive. (measured six inches above the ground) and should be of not shown on the plan. The trees (that are plant species common to the area. Such trees should ba to remain) are mostly cherry trees spaced located at least every 40 feet on center. 15' to 35' apart. 34 Landscaping along interior pedestrian ways: Sidewalk is provided between the proposed Increase the size of the a. Medium trees should be planted parallel to all interior building and parking rows on the south and Zelkova trees to 2%2" pedestrian ways. Such trees should be at least 2'/2 inches east sides of the building. In addition to the caliper minimum. caliper (measured six inches above the ground) and should three Zelkova trees on the west side be of a species common to the area. Such trees should be (Avon) of the site, two flowering plum located at least every 25 feet on center. trees are proposed in islands southeast of the building. 34 parking spaces are shown. 35 Landscaping of parking areas: a. Large trees should align the perimeter of parking areas, The Zelkova and plum trees meet the located 40 feet on center. Trees should be planted in the interior parking lot tree quantity interior of parking areas at the rate of one tree for every 10 requirement. The Zelkova are proposed at parking spaces provided and should be evenly distributed 2" caliper, which is less than the throughout the interior of the parking area. requirement. b. Trees required by the preceding paragraph should measure 2'/2 inches caliper (measured six inches above the A group of boxwoods is proposed at each ground); should be evenly spaced; and should be of a proposed tree. Given the elevation species common to the area. Such trees should be planted difference, shrubs in those locations are not in planters or medians sufficiently large to maintain the expected to have an impact on the EC. The health of the tree and shall be protected by curbing. shrubs are proposed at 12" high, which is c. Shrubs should be provided as necessary to minimize the less than the requirement. parking area's impact on Entrance Corridor streets. ShrWM should measure 24 inches in height. 37 Plant species: a. Plant species required should be as The proposed species are acceptable for None. approved by the Staff based upon but not limited to the this location. Generic Landscape Plan Recommended Species List and Native Plants for Virginia Landscapes (Appendix D). 38 Plant health: The following note should be added to the The note appears on sheet C8. None. landscape plan: "All site plantings of trees and shrubs shall be allowed to reach, and be maintained at, mature height; the topping of trees is prohibited. Shrubs and trees shall be pruned minimally and only to support the overall health of the plant." 17 Accessory structures and equipment should be integrated Parking is proposed on all four sides of the Revise the site plan to into the overall plan of development and shall, to the exteN building. A two -way travelway is provided clearly show the location, possible, be compatible,&ith the buildingjkdjW11WMJW on the south side of the building. It extent and material of the the site. becomes one -way on the west side, where angled parking is provided, and leads to compactor screening wall. Include a note on the plan 18 The following should be located to eliminate visibility from the Entrance Corridor street. If, after appropriate siting, these the donation drop -off point. After drop -off, stating that the compactor features will still have a negative visual impact on the traffic continues out past the building into will not exceed the height Entrance Corridor street, screening should be provided to the existing parking lot. of the screen wall. Include a eliminate visibility. a. Loading areas, b. Service areas, c. screen wall detail in the Refuse areas, d. Storage areas, e. Mechanical equipment, f. The building is oriented parallel to the plan. Above - ground utilities, and g. Chain link fence, barbed Avon Street Entrance Corridor. The front wire, razor wire, and similar security fencing devices. of the building faces Mill Creek Drive to the south. The back of the building faces Provide additional site sections and/or perspective 19 Screening devices should be compatible with the design of the buildings and surrounding natural vegetation and may north and includes a compactor with a views (as viewed from consist of. a. Walls, b. Plantings, and c. Fencing. brick screen wall. (The wall is shown in the elevations and perspective views, but Avon Street) to clarify the visibility of the 21 The following note should be added to the site plan and the architectural plan: "Visibility of all mechanical equipment isn't clearly identified on the site plan.) compactor /service area. from the Entrance Corridor shall be eliminated." This north elevation is expected to have some visibility from the Avon Street EC. A Show on the plan the 36 Landscaping of buildings and other structures: a. Trees or other vegetation should be planted along the perspective view shows the screen wall existing landscaping front of long buildings as necessary to soften the open on the EC side. Additional site located just north of the appearance of exterior walls. The spacing, size, and type of sections and/or perspective views would subject parcel that will help such trees or vegetation should be determined by the help clarify the extent of visibility of the screen views of the length, height, and blankness of such walls. compactor area, and whether or not the proposed building. b. Shrubs should be used to integrate the site, buildings, wall extends far enough for complete and other structures; dumpsters, accessory buildings and screening of the service area. Showing on Extend the screen wall as structures; "drive thru" windows; service areas; and signs. the plan the existing landscaping located necessary to fully screen Shrubs should measure at least 24 inches in height. just north of the subject parcel would also help clarify the extent of visibility. the service area from view. 39 The relationship of buildings and other structures to the Entrance Corridor street and to other development within Locate the ground- mounted the corridor should be as follows: The plan shows what looks like two mechanical units so they a. An organized pattern of roads, service lanes, bike paths, mechanical units on the EC side of the are screened by the brick and pedestrian walks should guide the layout of the site. compactor area. Depending on their size, screen wall. b. In general, buildings fronting the Entrance Corridor the mechanical units could be visible from street should be parallel to the street. Building groupings the EC; they would be better located Show the locations and should be arranged to parallel the Entrance Corridor street. behind the brick screen wall. heights of the rooftop c. Provisions should be made for connections to adjacent equipment on the plans and pedestrian and vehicular circulation systems. The donation drop -off and the compactor elevations. Include a d. Open spaces should be tied into surrounding areas to area are "service" areas that generally section to clarify that the provide continuity within the Entrance Corridor. would not be considered appropriate equipment will not be e. If significant natural features exist on the site (including features to be visible from the EC. visible from the EC. creek valleys, steep slopes, significant trees or rock Donation areas like the one proposed here outcroppings), to the extent practical, then such natural can become unsightly when donations are Add landscaping on site to features should be reflected in the site layout. If the left at building -side after business hours. In further mitigate the provisions of Section 32.5.6.n of the Albemarle County this case, the slope of the land adjacent to appearance of the north Zoning Ordinance apply, then improvements required by the EC is expected to screen the view of elevation. that section should be located so as to maximize the use of the lower part of the wall from drivers on existing features in screening such improvements from the EC, so the after -hours drop -offs aren't Entrance Corridor streets. expected to be an EC issue. f. The placement of structures on the site should respect existing views and vistas on and around the site. The elevation difference between road and building pad suggests that the storefront 6 Site development should be sensitive to the existing natural landscape and should contribute to the creation of an need not face the EC. Turning the building organized development plan. This may be accomplished, to 90 degrees counterclockwise could provide the extent practical, by preserving the trees and rolling additional opportunities for screening the terrain typical of the area; planting new trees along streets service areas (by tucking them both into and pedestrian ways and choosing species that reflect the existing slopes), but that would appear native forest elements; insuring that any grading will blend to complicate parking and traffic flow for into the surrounding topography thereby creating a the drop -off. Additional landscaping could continuous landscape; preserving, to the extent practical, further mitigate the appearance of the existing significant river and stream valleys which may be service areas. There is no planting strip located on the site and integrating these features into the available in the parking lot to help mitigate design of surrounding development; and limiting the the north elevation, but more plants could building mass and height to a scale that does not overpower be added along the EC frontage. the natural settings of the site, or the Entrance Corridor. A dumpster is located northwest of the building, adjacent to the slope. Because it is so close to the slope, it is not expected to be viewed from the EC. Currently, a striking view of the mountains is available from Avon Street, above and beyond the existing South Side Shopping Center building. It is anticipated that some of this view might be blocked by the proposed building. (The existing building reaches 32' high at its tallest. The proposed building appears to be approximately 25- 28' tall at its highest point.) There is potential for rooftop equipment to be visible due to the elevation of the road above the base elevation of the building. Equipment locations and heights are needed on the plans and elevations to show that rooftop equipment won't be visible. A site section would further clarify visibility. Site Grading 40 Site grading should maintain the basic relationship of the site There is an abrupt change in elevation None. to surrounding conditions by limiting the use of retaining between the site, which has already been walls and by shaping the terrain through the use of smooth, graded, and the adjacent streets. The rounded land forms that blend with the existing terrain. Steep proposed development will maintain this cut or fill sections are generally unacceptable. Proposed basic relationship of site to surroundings, contours on the grading plan shall be rounded with a ten fool though the slope will be cut into on both minimum radius where they meet the adjacent condition. the west (Avon) and south (Mill creek) Final grading should achieve a natural, rather than sides. Retaining walls are proposed in engineered, appearance. Retaining walls 6 feet in height and these areas, but visibility of the walls from taller, when necessary, shall be terraced and planted to blen4 the EC is expected to be low and the with the landscape. impact of the walls on the EC is not expected to be great. 41 No grading, trenching, or tunneling should occur within the Existing tree locations are shown on the Revise the plan to show drip line of any trees or other existing features designated for plan, but drip lines are not shown. Existing accurate drip lines for all preservation in the fmal Certificate of Appropriateness. shrubs along Avon Street and Mill Creek existing trees and to show SUMMARY OF RECOMMENDATIONS Staff recommends the following as the primary points of discussion: 1. Visibility of the building and service areas from the EC 2. The orientation of the building 3. The brick screening wall for the compactor area 4. The detailing of the walls, the transom windows, the proportions of the wall divisions Regarding the Initial Site Plan, staff recommends that the ARB forward the following recommendations to the Agent for the Site Review Committee: Regarding requirements to satisfy the design guidelines: As per § 32.4.2.2(b)(3) and 30.6.4(c)(2) and (3) and EC Guidelines #17 and 18, service areas and equipment are not sufficiently integrated into the development and visibility of service areas and equipment is not eliminated. Regarding recommendations on the plan as it relates to the guidelines: None. Regarding recommended conditions of initial plan approval: • A Certificate of Appropriateness is required prior to final site plan approval. • Provide additional landscaping on site, outside of utilities and easements, to help better integrate service areas and equipment into the corridor, and to eliminate visibility of service areas and equipment. Regarding conditions to be satisfied prior to issuance of a grading permit: • Revise the plan to show accurate drip lines of all trees to remain. Maintain grading outside of the drip lines of trees to remain. • Revise the plan to show existing shrubs to remain along Avon Street and Mill Creek Drive. 10 Adequate tree protection fencing should be shown on, and Drive are not shown on the plan. The existing shrubs along Avon coordinated throughout, the grading, landscaping and erosion impact of proposed grading can't be fully Street and Mill Creek and sediment control plans. determined without drip lines shown on the plan. Drive. Ensure that grading won't negatively impact 42 Areas designated for preservation in the final Certificate of Appropriateness should be clearly delineated and protected existing trees to remain. on the site prior to any grading activity on the site. This protection should remain in place until completion of the development of the site. 43 Preservation areas should be protected from storage or movement of heavy equipment within this area. 20 Surface runoff structures and detention ponds should be The proposed development will tie into the None. designed to fit into the natural topography to avoid the need existing drainage pattern. for screening. When visible from the Entrance Corridor street, these features must be fully integrated into the landscape. They should not have the appearance of engineered features. 44 Natural drainage patterns (or to the extent required, new drainage patterns) should be incorporated into the finished site to the extent possible. SUMMARY OF RECOMMENDATIONS Staff recommends the following as the primary points of discussion: 1. Visibility of the building and service areas from the EC 2. The orientation of the building 3. The brick screening wall for the compactor area 4. The detailing of the walls, the transom windows, the proportions of the wall divisions Regarding the Initial Site Plan, staff recommends that the ARB forward the following recommendations to the Agent for the Site Review Committee: Regarding requirements to satisfy the design guidelines: As per § 32.4.2.2(b)(3) and 30.6.4(c)(2) and (3) and EC Guidelines #17 and 18, service areas and equipment are not sufficiently integrated into the development and visibility of service areas and equipment is not eliminated. Regarding recommendations on the plan as it relates to the guidelines: None. Regarding recommended conditions of initial plan approval: • A Certificate of Appropriateness is required prior to final site plan approval. • Provide additional landscaping on site, outside of utilities and easements, to help better integrate service areas and equipment into the corridor, and to eliminate visibility of service areas and equipment. Regarding conditions to be satisfied prior to issuance of a grading permit: • Revise the plan to show accurate drip lines of all trees to remain. Maintain grading outside of the drip lines of trees to remain. • Revise the plan to show existing shrubs to remain along Avon Street and Mill Creek Drive. 10 Staff offers the following comments on the preliminary proposal: 1. Indicate on the drawings the material and color intended for the back of the pedimented entrance features. Choose a material and color that is integrated with the overall building. 2. Revise the site plan to show the entrance pavilion. 3. Confirm that the lighter color horizontal courses shown in the color renderings are a lighter color brick, as is seen in the existing shopping center. Identify the material and color on the drawings. 4. Adjust the brick detailing to eliminate the top -heavy appearance of the walls. 5. Provide on the plan details on the window glass indicating that visible light transmittance (VLT) shall not drop below 40% and visible light reflectance (VLR) shall not exceed 30 %. 6. Revise the maintenance factor (LLF) to 1.0 for all proposed light fixtures and recalculate the photometrics. Provide a point -by -point grid style photometric plan for review. 7. Provide cut sheets for the proposed light fixtures in the site plan. 8. Confirm that the proposed lamp type matches that which is currently used in the shopping center. 9. Identify the fixture and pole colors in the light schedule or with a note on the lighting plan. Bronze is recommended. 10. Include the standard lighting note on the plan. 11. Show on the plan the shrubs that exist along Avon and Mill Creek. Show the existing trees and shrubs that are to remain with accurate drip lines. 12. Move the new telephone and power lines outside of planting areas. 13. Provide interspersed ornamental trees on site, along Avon Street. 14. Provide additional landscaping on site, outside of utilities, to help better integrate the building and its service areas into the corridor. 15. Show on the plan the existing shrubs along Mill Creek Drive. 16. Increase the size of the Zelkova trees to 2'/z" caliper minimum. 17. Revise the site plan to clearly show the location, extent and material of the compactor screening wall. Include a note on the plan stating that the compactor will not exceed the height of the screen wall. Include a screen wall detail in the plan. 18. Provide additional site sections and/or perspective views (as viewed from Avon Street) to clarify the visibility of the compactor /service area. 19. Show on the plan the existing landscaping located just north of the subject parcel that will help screen views of the proposed building. 20. Extend the screen wall as necessary to fully screen the service area from view. 21. Locate the ground- mounted mechanical units so they are screened by the brick screen wall. 22. Add landscaping on site to further mitigate the appearance of the north elevation. 23. Show the locations and heights of the rooftop equipment on the plans and elevations. Include a section to clarify that the equipment will not be visible from the EC. 24. Revise the plan to show accurate drip lines for all existing trees and to show existing shrubs along Avon Street and Mill Creek Drive. Ensure that grading won't negatively impact existing trees to remain. 11 TABLE A This report is based on the following submittal items: Sheet # Drawing Name Drawing Date C 1 Cover 2 -21 -2014 C2 Existing Conditions & ESC Phase 1 Plan 2 -21 -2014 C3 I Layout & Utility Plan 2 -21 -2014 C4 Grading & ESC Ph. 2 Plan 2 -21 -2014 C5 ESC Notes 2 -21 -2014 C6 ESC Details 2 -21 -2014 C7 Site Details 2 -21 -2014 C8 Landscape & Lighting Plan 2 -21 -2014 - I Architectural Elevations — South and West - - Architectural Elevations — North and East - - Rendering from Avon St. & Mill Creek Dr. Intersection Looking East - - Rendering from Avon St. Looking South - - Rendering from Southside Shopping Center Entrance Looking North -West - - Site Sections Through Proposed Building - - Existing Street View from Avon St. & Mill Creek Dr. Intersection Looking North -East - - Existing Street View from Avon St. Looking South -West - - Existing Building at Southside Shopping Center - 12