HomeMy WebLinkAboutARB201500018 Review Comments Initial Site Plan 2015-03-10ARCHITECTURAL REVIEW BOARD STAFF REPORT
Project #/Name
ARB- 2015 -18: Fifth Street Place Initial Site Plan
Review Type
Initial Site Development Plan and preliminary architectural review
Parcel Identification
07600000005400, 076000000054A, 076000000054A2, 076000000054A3, 076000000055, 076000000055B,
076000000055D
Location
At the southwest corner of the intersection of I64 and 5th Street Extended
Zoned
Residential (R15) /Entrance Corridor (EC)
Owner /Applicant
N &S LC, Gambit LLC, Prana Land LLC etal/Dominion Realty Partners (Michael M. Campbell)
Magisterial District
Scottsville
Proposal
To construct multi - family housing consisting of 200 apartment units in 5 buildings with associated site
improvements.
Context
Multi- family housing is located to the west of the subject parcel. Single family residences are located across 5`" Street
to the south, I64 is located to the north, with the off -ramp to the north/northeast.
Visibility
The development is expected to be visible, but existing wooded area to remain along the 164 corridor and along
portions of 5th Street Extended will limit some views. In the winter, intermittent views are available from 5th Street to
I64, and from I64 to 5th Street.
ARB Meeting Date
March 16, 2015
Staff Contact
Margaret Maliszewski
PROJECT HISTORY
The ARB has reviewed no previous proposals for this site.
ANALYSIS
Gray highlight = means the guideline can't be reviewed at initial site plan stage, but recommendations can be provided for final
Yellow highlight = means the guideline can only be reviewed for location/configuration at the initial plan stage
Regular text = means the guideline can be reviewed at initial plan stage, can be made a condition of initial plan approval, and can be the basis for denial
REF
GUIDELINE
ISSUE
RECOMMENDATION
Structure design
1
The goal of the regulation of the design of development
Preliminary elevations have been
Submit elevations
within the designated Entrance Corridors is to insure that new
submitted for both the 3 -story and
addressing all sides of
development within the corridors reflects the traditional
4 -story apartment buildings (one
each building.
architecture of the area. Therefore, it is the purpose of ARB
each). A color perspective of the
review and of these Guidelines, that proposed development
poolside view of the clubhouse
within the designated Entrance Corridors reflect elements of
has also been submitted. The
design characteristic of the significant historical landmarks,
designs are for clearly modern
buildings, and structures of the Charlottesville and Albemarle
buildings, but the materials (red
area, and to promote orderly and attractive development
brick, cementitious fiber board
within these corridors. Applicants should note that replication
siding, stone, asphalt shingles,
of historic structures is neither required nor desired
and vinyl window frames) are
2
Visitors to the significant historical sites in the Charlottesville
compatible with those of the
and Albemarle area experience these sites as ensembles of
historic buildings of the area.
buildings, land, and vegetation. In order to accomplish the
integration of buildings, land, and vegetation characteristic of
these sites, the Guidelines require attention to four primary
factors: compatibility with significant historic sites in the
area; the character of the Entrance Corridor; site development
and layout; and landscaping.
3
New structures and substantial additions to existing structures
should respect the traditions of the architecture of historically
significant buildings in the Charlottesville and Albemarle
area. Photographs of historic buildings in the area, as well as
drawings of architectural features, which provide important
examples of this tradition are contained in Appendix A.
4
The examples contained in Appendix A should be used as a
guide for building design: the standard of compatibility with
the area's historic structures is not intended to impose a rigid
design solution for new development. Replication of the
design of the important historic sites in the area is neither
intended nor desired. The Guideline's standard of
compatibility can be met through building scale, materials,
and forms which may be embodied in architecture which is
contemporary as well as traditional. The Guidelines allow
individuality in design to accommodate varying tastes as well
as special functional requirements.
9
Building forms and features, including roofs, windows, doors,
materials, colors and textures should be compatible with the
forms and features of the significant historic buildings in the
area, exemplified by (but not limited to) the buildings
described in Appendix A [of the design guidelines]. The
standard of compatibility can be met through scale, materials,
and forms which may be embodied in architecture which is
contemporary as well as traditional. The replication of
important historic sites in Albemarle County is not the
objective of these guidelines.
I I
The overall design of buildings should have human scale.
At 3 and 4 stories, 45' and 59'
None.
Scale should be integral to the building and site design.
tall, and ranging from 65' x 65'
for the clubhouse to
approximately 70' x 335' for the
4 -story building, the proposed
buildings are large. However, the
designs have sufficient
architectural treatment (material
changes, water tables, projections,
balconies, window openings) to
establish human scale.
5
It is also an important objective of the Guidelines to establish
Only two elevations have been
None.
a pattern of compatible architectural characteristics
submitted, but it is anticipated
throughout the Entrance Corridor in order to achieve unity
that the forms, materials and
and coherence. Building designs should demonstrate
general design illustrated in the
sensitivity to other nearby structures within the Entrance
submitted elevations will be
Corridor. Where a designated corridor is substantially
carried throughout the
developed, these Guidelines require striking a careful balaM
development.
between harmonizing new development with the existing
character of the corridor and achieving compatibility with the
significant historic sites in the area.
The form, materials and detailing
of the proposed apartment
10
Buildings should relate to their site and the surrounding
context of buildings.
buildings are compatible with
those of the apartment complex to
12
Architecture proposed within the Entrance Corridor should
use forms, shapes, scale, and materials to create a cohesive
the west. The materials are also
whole.
compatible with the single family
residences in the area.
13
Any appearance of "blankness" resulting from building
Blankness is not a characteristic
Submit all elevations for
design should be relieved using design detail or vegetation, oil
of the elevations that have been
review. Ensure that
both.
submitted for review. It is
blankness is not a
anticipated that these elevations
characteristic of the
are representative of all four sides
design.
of each building.
14
Arcades, colonnades, or other architectural connecting
The proposed buildings are not
None.
devices should be used to unify groups of buildings within a
physically connected but are
development.
visually connected through the
use of form, materials, and design
details.
15
Trademark buildings and related features should be modified
Buildings may have been
None.
to meet the requirements of the Guidelines.
constructed according to the
proposed designs in other
locations, but the buildings are
not expected to have the
appearance of trademark designs.
16
Window glass in the Entrance Corridors should not be highly
The note will be needed on the
Add the standard window
tinted or highly reflective. Window glass in the Entrance
architectural plans.
glass note to the
Corridors should meet the following criteria: Visible light
architectural drawings.
transmittance (VLT) shall not drop below 4001o. Visible light
reflectance (VLR) shall not exceed 3001o. Specifications on the
proposed window glass should be submitted with the application
for final review.
Accessory structures and equipment
17
Accessory structures and equipment should be integrated into
A mail kiosk, swimming pool,
None.
the overall plan of development End shall, to the extent
and dumpster /recycling center are
possible, be compatible with the building designs used on the
proposed within the development.
The swimming pool is screened
18
The following should be located to eliminate visibility from
the Entrance Corridor street. If, after appropriate siting, these
from the 5th Street EC by the
features will still have a negative visual impact on the
clubhouse. The mail kiosk may be
Entrance Corridor street, screening should be provided to
seen from the 5th Street EC along
eliminate visibility. a. Loading areas, b. Service areas, c.
the entrance drive, but it is not
Refuse areas, d. Storage areas, e. Mechanical equipment, f,
expected to have a negative
Above - ground utilities, and g. Chain link fence, barbed wire,
impact. The dumpster is located
razor wire, and similar security fencing devices.
internal to the site and trees and
existing wooded area are located
19
Screening devices should be compatible with the design of
the buildings and surrounding natural vegetation and may
between it and the EC. It is not
consist of. a. Walls, b. Plantings, and c. Fencing.
expected to be noticed from the
ECs.
21
The following note should be added to the site plan and the
The note is needed on the plans.
Add the standard
architectural plan: "Visibility of all mechanical equipment
mechanical equipment
from the Entrance Corridor shall be eliminated."
note to both the
architectural and site
plans.
Lighting
22
Light should be contained on the site and not spill over onto
The photometric plan is small and
Provide the photometric
adjacent properties or streets;
hard to read, but it looks like
plan at a larger size to
spillover exceeds .5 footcandles
increase legibility.
at the entrance to the
development. The light levels
Revise the lighting plan
were calculated using an LLF of
to eliminate spillover at
.92. To meet County regulations,
the property line in
an LLF of 1.0 is required
excess of .5 footcandles.
Revise the lighting plan
using an LLF of 1.0.
23
Light should be shielded, recessed or flush - mounted to
The proposed fixtures are full
None.
eliminate glare. All fixtures with lamps emitting 3000
cutoff.
lumens or more must be full cutoff fixtures.
24
Light levels exceeding 30 footcandles are not appropriate
Light levels do not appear to
Provide the photometric
for display lots in the Entrance Corridors. Lower light
exceed 12 footcandles, but the
plan at a larger size to
levels will apply to most other uses in the Entrance
plan is difficult to read.
increase legibility.
Corridors.
25
Light should have the appearance of white light with a
LED fixtures are proposed
None.
warm soft glow; however, a consistent appearance
throughout the development.
throughout a site or development is required.
Consequently, if existing lamps that emit non -white light
are to remain, new lamps may be required to match them.
26
Dark brown, dark bronze, or black are appropriate colors for
Pole and fixture finish have not
Identify the pole and
free - standing pole mounted light fixtures in the Entrance
been identified.
fixture colors on the
Corridors.
lighting plan. Bronze is
recommended.
27
The height and scale of freestanding, pole- mounted light
The pole detail shows a 16' pole
None.
fixtures should be compatible with the height and scale of
on a 3.5' base.
the buildings and the sites they are illuminating, and with
the use of the site. Typically, the height of freestanding
pole- mounted light fixtures in the Entrance Corridors
should not exceed 20 feet, including the base. Fixtures that
exceed 20 feet in height will typically require additional
screening to achieve an appropriate appearance from the
Entrance Corridor.
28
In determining the appropriateness of lighting fixtures for
The proposed fixtures appear
None.
the Entrance Corridors, the individual context of the site
appropriate for the site.
will be taken into consideration on a case by case basis.
29
The following note should be included on the lighting plan:
The note does not appear on the
Add the standard lighting
"Each outdoor luminaire equipped with a lamp that emits
plan.
note to the plan.
3,000 or more initial lumens shall be a full cutoff luminaire
and shall be arranged or shielded to reflect light away from
adjoining residential districts and away from adjacent
roads. The spillover of lighting from luminaires onto
public roads and property in residential or rural areas
zoning districts shall not exceed one half footcandle."
Guidelines for the Use of Decorative Landscape Lighting
No decorative landscape lighting
None.
is proposed.
Landscaping
7
The requirements of the Guidelines regarding landscaping are
Some existing wooded area is
In areas where wooded
intended to reflect the landscaping characteristic of many of
the area's significant historic sites which is characterized by
large shade trees and lawns. Landscaping should promote
visual order within the Entrance Corridor and help to
integrate buildings into the existing environment of the
corridor.
proposed to remain and to
account for some frontage tree
requirements along 5th Street. In
areas where there are no existing
trees, large trees are shown at 35'
on center and ornamental trees
are interspersed. To ensure that
area to remain is to
account for frontage tree
requirements along 5th
Street, identify individual
existing large shade and
ornamental trees on the
plan by size and species
8
ontinuity within the Entrance Corridor should be obtained
by planting different types of plant materials that share
remaining wooded area meets
to show that the
similar characteristics. Such common elements allow for
more flexibility in the design of structures because common
minimum requirements,
minimum requirement
individual trees to remain (large
can be met.
landscape features will help to harmonize the appearance of
shade trees and ornamentals)
development as seen from the street upon which the Corridor
should be identified on the plans
Show existing and
is centered.
(by size and species).
proposed utilities and
32
Landscaping along the frontage of Entrance Corridor streets
should include the following:
easements on the
a. Large shade trees should be planted parallel to the Entrance
There is substantial wooded area
landscape plan.
Corridor Street. Such trees should be at least 3'h inches
to remain on the I64 side of the
caliper (measured 6 inches above the ground) and should be
property, so frontage trees are not
Shift utilities to eliminate
of a plant species common to the area. Such trees should be
provided along that side of the
conflicts between
located at least every 35 feet on center.
development.
landscaping and
b. Flowering ornamental trees of a species common to the
utilities /easements
area should be interspersed among the trees required by the
The utility plans show new water
without reducing the
preceding paragraph. The ornamental trees need not alternate
and sewer lines running near the
quantity of proposed
one for one with the large shade trees. They may be planted
5th Street corridor at the west end
plants.
among the large shade trees in a less regular spacing pattern.
of the property. A 20' public
c. In situations where appropriate, a three or four board few
utility easement is proposed in the
or low stone wall, typical of the area, should align the
development. This easement and
frontage of the Entrance Corridor street.
the water and sewer lines appear
d. An area of sufficient width to accommodate the foregoing
to conflict with several tree
plantings and fencing should be reserved parallel to the
locations. Utilities should be
Entrance Corridor street, and exclusive of road right -of -way
shifted to eliminate landscape
and utility easements.
conflicts without reducing the
quantity of proposed plants.
Including the utilities and
easements on the landscape plan
would simplify coordination.
33
Landscaping along interior roads:
Trees are shown along the
Ensure that pipes are
a. Large trees should be planted parallel to all interior roads.
entrance drive at the required size
located to eliminate
Such trees should be at least 2'/2 inches caliper (measured six
and spacing. However, a storm
conflicts with trees along
inches above the ground) and should be of a plant species
pipe runs along the east side of
the entrance drive, while
common to the area. Such trees should be located at least
the drive, close to the trees.
meeting the 40' on center
every 40 feet on center.
tree requirement.
34
Landscaping along interior pedestrian ways:
Most sidewalks in the
None.
a. Medium trees should be planted parallel to all interior
development run along the
pedestrian ways. Such trees should be at least 2'/2 inches
parking lots, where perimeter
caliper (measured six inches above the ground) and should be
trees are provided. A few
of a species common to the area. Such trees should be located
sidewalks run along buildings
at least every 25 feet on center.
where trees are not provided, but
there are sufficient trees
elsewhere on site to compensate.
35
Landscaping of parking areas:
Trees are provided at the
Ensure that pipes are
a. Large trees should align the perimeter of parking areas,
perimeter of parking lots at the
located to eliminate
located 40 feet on center. Trees should be planted in the
size and spacing required. There
conflicts with trees along
interior of parking areas at the rate of one tree for every 10
are potential conflicts with storm
the entrance drive.
parking spaces provided and should be evenly distributed
pipes in several locations.
throughout the interior of the parking area.
b. Trees required by the preceding paragraph should measure
Shrubs are provided at the
2'/2 inches caliper (measured six inches above the ground);
required size along the south side
should be evenly spaced; and should be of a species common
of the parking lot that fronts the
to the area. Such trees should be planted in planters or
clubhouse and along the north
medians sufficiently large to maintain the health of the tree
side of the parking lot closest to
and shall be protected by curbing.
the I64 off -ramp. Other parking
c. Shrubs should be provided as necessary to minimize the
lots are set further back from the
parking area's impact on Entrance Corridor streets. Shrubs
ECs and located behind buildings
should measure 24 inches in height.
or wooded area as viewed from
the ECs, such that shrubs would
not impact the view from the EC.
36
Landscaping of buildings and other structures:
Based on the elevations
None.
a. Trees or other vegetation should be planted along the front
submitted, blankness is not an
of long buildings as necessary to soften the appearance of
issue, so additional trees are not
exterior walls. The spacing, size, and type of such trees or
needed for softening the
vegetation should be determined by the length, height, and
appearance of the buildings.
blankness of such walls.
b. Shrubs should be used to integrate the site, buildings, and
other structures; dumpsters, accessory buildings and
structures; "drive thru" windows; service areas; and signs.
Shrubs should measure at least 24 inches in height.
37
Plant species: a. Plant species required should be as approved
Species have not yet been
None at this time.
by the Staff based upon but not limited to the Generic
identified.
Landscape Plan Recommended Species List and Native
Plants or Virginia Landscapes (Appendix D).
38
Plant health: The following note should be added to the
The note appears on sheet L2.01.
None.
landscape plan: "All site plantings of trees and shrubs shall be
allowed to reach, and be maintained at, mature height; the
topping of trees is prohibited. Shrubs and trees shall be pruned
inimally and only to support the overall health of the plant."
Development pattern and site grading
6
Site development should be sensitive to the existing natural
The overall layout appears
Add trees along the
landscape and should contribute to the creation of an
organized. Buildings are more or
retaining wall located
organized development plan. This may be accomplished, to
less arranged parallel to the ECs,
west of the clubhouse to
the extent practical, by preserving the trees and rolling terrain
and parking lots are located
soften the appearance of
typical of the area; planting new trees along streets and
interior to the site, screened by
the wall as viewed from
pedestrian ways and choosing species that reflect native forest
buildings as viewed from the EC.
the 5th Street corridor.
elements; insuring that any grading will blend into the
surrounding topography thereby creating a continuous
The existing site is characterized
Indicate on the site plan
landscape; preserving, to the extent practical, existing
by wooded, rolling terrain.
the manufacturer, size
significant river and stream valleys which may be located on
Retaining walls are proposed
and color of the block
the site and integrating these features into the design of
north of Building 1, north of the
proposed for the
surrounding development; and limiting the building mass and
parking lot located between the
retaining walls.
height to a scale that does not overpower the natural settings
clubhouse and Building 1, and
of the site, or the Entrance Corridor.
west of the clubhouse and
Provide details on the plan
39
The relationship of buildings and other structures to the
Entrance Corridor street and to other development within the
swimming pool. The walls north
of Building 1 are terraced and
showing that wall
construction will allow for
corridor should be as follows:
a. An organized pattern of roads, service lanes, bike paths,
planted. The wall north of the
the planting between the
terraced walls illustrated
and pedestrian walks should guide the layout of the site.
arkin lot reaches 10' high. It is
p g g
north of Buildings 1 and 2.
b. In general, buildings fronting the Entrance Corridor street
located a considerable difference
should be parallel to the street. Building groupings should be
from the I64 corridor and a
10
arranged to parallel the Entrance Corridor street.
wooded area is located between it
c. Provisions should be made for connections to adjacent
and the corridor. This interim
pedestrian and vehicular circulation systems.
wooded area is expected to be
d. Open spaces should be tied into surrounding areas to
sufficient to blend the wall into
provide continuity within the Entrance Corridor.
the landscape. The wall west of
e. If significant natural features exist on the site (including
the clubhouse reaches 9' high. It
creek valleys, steep slopes, significant trees or rock
would be visible to eastbound
outcroppings), to the extent practical, then such natural
traffic on 5th Street. Proposed EC
features should be reflected in the site layout. If the
frontage trees will help reduce
provisions of Section 32.5.6.n of the Albemarle County
visibility, but plants close to the
Zoning Ordinance apply, then improvements required by that
wall would more successfully
section should be located so as to maximize the use of
soften the impact of the wall.
existing features in screening such improvements from
Entrance Corridor streets.
£ The placement of structures on the site should respect
The walls are labeled as "dry
existing views and vistas on and around the site.
stack masonry unit retaining
wall". Color and block size are
40
Site grading should maintain the basic relationship of the site
to surrounding conditions by limiting the use of retaining
not provided on the plans.
walls and by shaping the terrain through the use of smooth,
rounded land forms that blend with the existing terrain. Steep
Grading has been revised from
cut or fill sections are generally unacceptable. Proposed
earlier designs discussed at pre -
contours on the grading plan shall be rounded with a ten foot
application meetings. The result
minimum radius where they meet the adjacent condition.
is retaining walls located to allow
Final grading should achieve a natural, rather than
for a better relationship of
engineered, appearance. Retaining walls 6 feet in height and
buildings to the 5 Street
taller, when necessary, shall be terraced and planted toblend
corridor.
with the landscape.
41
No grading, trenching, or tunneling should occur within the
New tree lines are shown
None.
drip line of any trees or other existing features designated for
throughout the development;
preservation in the final Certificate of Appropriateness.
individual trees to remain are not
Adequate tree protection fencing should be shown on, and
shown. Tree protection fencing is
coordinated throughout, the grading, landscaping and erosion
shown on the E &S plan.
and sediment control plans.
42
Areas designated for preservation in the final Certificate of
Appropriateness should be clearly delineated and protected
on the site prior to any grading activity on the site. This
10
SUMMARY OF RECOMMENDATIONS
Staff recommends the following as the primary points of discussion:
1. General appearance of the proposed apartment buildings and club house; appropriateness for the ECs
2. Frontage planting along 5th Street Extended and I64
3. Visibility and treatment of proposed retaining walls
Staff recommends that the ARB forward the following recommendations to the Agent for the Site Review Committee:
Regarding requirements to satisfy the design guidelines as per § 18- 30.6.4(2), (3) and (5):
1. In areas where wooded area to remain is used to meet tree requirements along 5th Street Extended, identify existing individual large
shade and ornamental trees on the plan by size and species to show that the minimum requirement can be met. If the requirement
can't be met, show additional new trees to be planted to meet the requirement.
2. Shift utilities to eliminate conflicts between landscaping and utilities /easements without reducing the quantity of proposed plants.
3. Ensure that pipes are located to eliminate conflicts with trees along the entrance drive, while meeting the 40' on center tree
requirement.
4. Add plants along the retaining wall located west of the clubhouse to soften the appearance of the wall as viewed from the 5th Street
Extended corridor.
ii
protection should remain in place until completion of the
development of the site.
43
Preservation areas should be protected from storage or
movement of heavy equipment within this area.
20
Surface runoff structures and detention ponds should be
A stormwater facility exists at the
None.
designed to fit into the natural topography to avoid the need
west end of the property.
for screening. When visible from the Entrance Corridor
street, these features must be fully integrated into the
landscape. They should not have the appearance of
engineered features.
44
Natural drainage patterns (or to the extent required, new
drainage patterns) should be incorporated into the finished
site to the extent possible.
SUMMARY OF RECOMMENDATIONS
Staff recommends the following as the primary points of discussion:
1. General appearance of the proposed apartment buildings and club house; appropriateness for the ECs
2. Frontage planting along 5th Street Extended and I64
3. Visibility and treatment of proposed retaining walls
Staff recommends that the ARB forward the following recommendations to the Agent for the Site Review Committee:
Regarding requirements to satisfy the design guidelines as per § 18- 30.6.4(2), (3) and (5):
1. In areas where wooded area to remain is used to meet tree requirements along 5th Street Extended, identify existing individual large
shade and ornamental trees on the plan by size and species to show that the minimum requirement can be met. If the requirement
can't be met, show additional new trees to be planted to meet the requirement.
2. Shift utilities to eliminate conflicts between landscaping and utilities /easements without reducing the quantity of proposed plants.
3. Ensure that pipes are located to eliminate conflicts with trees along the entrance drive, while meeting the 40' on center tree
requirement.
4. Add plants along the retaining wall located west of the clubhouse to soften the appearance of the wall as viewed from the 5th Street
Extended corridor.
ii
5. Indicate on the plans the manufacturer, size and color of the block proposed for the retaining walls. Provide details on the plan
showing that wall construction will allow for the planting between the terraced walls illustrated north of Buildings 1 and 2.
Regarding recommendations on the plan as it relates to the guidelines:
None.
Regarding recommended conditions of initial plan approval: A Certificate of Appropriateness is required prior to final site plan
approval.
1. Submit elevations addressing all sides of each building. Ensure that blankness is not a characteristic of the design.
2. Add the standard window glass note to the architectural drawings: "Visible light transmittance (VLT) shall not drop below 40 %.
Visible light reflectance (VLR) shall not exceed 30 %."
3. Add the standard mechanical equipment note to both the architectural and site plans: "Visibility of all mechanical equipment from
the Entrance Corridor shall be eliminated."
4. Provide the photometric plan at a larger size to increase legibility.
5. Revise the lighting plan to eliminate spillover at the property line in excess of .5 footcandles.
6. Revise the lighting plan using an LLF of 1.0.
7. Identify the light pole and light fixture colors on the lighting plan. Bronze is recommended.
8. Add the standard lighting note to the plan: "Each outdoor luminaire equipped with a lamp that emits 3,000 or more initial lumens
shall be a full cutoff luminaire and shall be arranged or shielded to reflect light away from adjoining residential districts and away
from adjacent roads. The spillover of lighting from luminaires onto public roads and property in residential or rural areas zoning
districts shall not exceed one half footcandle."
9. In areas where wooded area to remain is used to meet tree requirements along 5th Street Extended, identify existing individual large
shade and ornamental trees on the plan by size and species to show that the minimum requirement can be met. If the requirement
can't be met, show additional new trees to be planted to meet the requirement.
10. Show existing and proposed utilities and easements on the landscape plan.
11. Shift utilities to eliminate conflicts between landscaping and utilities /easements without reducing the quantity of proposed plants.
12. Ensure that pipes are located to eliminate conflicts with trees along the entrance drive, while meeting the 40' on center tree
requirement.
13. Add trees along the retaining wall located west of the clubhouse to soften the appearance of the wall as viewed from the 5th Street
Extended corridor.
14. Indicate on the site plan the manufacturer, size and color of the block proposed for the retaining walls. Provide details on the plan
showing that wall construction will allow for the planting between the walls illustrated north of Buildings 1 and 2.
Regarding conditions to be satisfied prior to issuance of a grading permit:
None.
12
TABLE A
This report is based on the following submittal items:
Sheet #
Drawing Name
Drawing Date
C -01
Cover Sheet
3/1/2015
C -02 and C -03
Existing Conditions Plan
3/1/2015
C -04
Erosion and Sediment Control details
3/1/2015
C -05 and C -06
Erosion and Sediment Control Plan
3/1/2015
C -07 and C -08
Overall
3/1/2015
C -09A thru C -09F
Layout Plan
3/1/2015
C -IOA thru C -IOF
Utilities Plan
3/1/2015
C-1 IA thru C-1 IF
Grading and Drainage Plan
3/1/2015
C -12
Sight Distance Plan and Profile
3/1/2015
C -13
Pre/Post impervious Area Map
3/1/2015
C -14
Approvals /Conditions
3/1/2015
LO.00
Site Context
2/2/2015
L1.01
Overall Planting Plan
2/2/2015
L2.01
Plant Schedule, Calculations and Details
2/2/2015
L3.01
Overall Lighting Plan
2/2/2015
L3.02
Lighting Cut Sheets
2/2/2015
Architectural site plan, elevations (3 story and 4 story), floor plans, club house /pool color
perspective, materials sheet
1/28/2015
Photos: Views of the site from the Entrance Corridors
13