HomeMy WebLinkAboutSDP201500013 Review Comments Minor Amendment 2015-04-07�'IRGII�ZP COUNTY OF ALBEMARLE Department of Community Development 401 McIntire Road, North Wing Charlottesville, Virginia 22902 -4596 Phone (434) 296 -5832 Fax (434) 972 -4126 April 7, 2015 Chip Votava 272 Bendix Road, Suite 400 Virginia Beach, VA 23452 RE: SDP201500013 ACSA Admin & Operations Center — Minor Amendment Dear Sir: Your Minor Amendment application has been reviewed. In order for the amended site plan to be approved the following revisions are required: 1. [Comment] This application is now being processed as a Minor Amendment; revise the cover sheet to replace `major' with `minor'. 2. [Comment] Provide a list of all proposed changes on the Cover Sheet. 3. [32.5.2(a)] Add Entrance Corridor (EC) to the Zoning note. 4. [32.5.2(a)] Add a note indicating the source of the topography and boundary information. 5. [32.5.2(d)] This property includes several areas of Managed Steep Slopes. Show all steep slope areas and label accordingly. 6. [32.5.2(i)] Label the access road to this site, indicate if it is public or private, and provide its right -of- way and pavement widths. 7. [32.5.2Q,k,l)] Verify that the location(s) and dimensions of all existing or proposed utilities and utility easements including water, sewer, drainage, telephone, cable, electric and gas are shown on the plan. Provide the Deed Book and Page reference for any existing easements. Any proposed easements should be labeled with the intended owner. 8. [32.5.2(n)] Clarify the location of, and dimension, the proposed fuel canopy on the site plan sheet. 9. [32.5.2(n)] Dimension the access aisles around the proposed fuel pumps. 10. [32.5.2(n)] Dimension the areas of demolished asphalt and concrete and the replacement areas, if different. 11. [32.5.2(n) & 5.1.20(b)] All fuel storage tanks in excess of 600 gallons, and their associated loading areas, must be at least 100' from all property lines. Provide dimensions on the site plan sheet to verify that this requirement is satisfied. 12. [32.6.2(k) & 4.17] Clarify which fixtures shown on the lighting plan are existing and which are proposed. 13. [32.6.2(k) & 4.17] For all proposed fixtures, provide a luminaire schedule listing the number of each fixture proposed along with the manufacturer's catalog number. The cutsheets must include manufacturer information and match the catalog number listed in the luminaire schedule. 14. [32.6.2(k) & 4.17] Verify that the photometric plan includes all existing and proposed lighting. 15. [Comment] This amendment cannot be approved until VDOT completes their review and grants their approval; comments will be forwarded upon receipt. ACSA, Fire /Rescue, and Inspections have reviewed the plan and have no objection. Engineering and ARB comments have been provided. Staff has provided references to provisions of Chapter 18 of the Code of the County of Albemarle. The Code is kept up to date by the County Attorney's office. The Code may found on the County Attorney's website which may be found under "Departments and Services" at Albemarle.org. In accord with the provisions of Section 32.4.3.5 of Chapter 18 of the Code if the developer fails to submit a revised final site plan to address all of the requirements within six (6) months after the date of this letter the application shall be deemed to have been voluntarily withdrawn by the developer. If you have any questions about the comments please feel free to contact me. Sincerely, &U- ('. 249-b Ellie Carter Ray, CLA Senior Planner Planning Division