HomeMy WebLinkAboutSDP201300025 Approval - Agencies Final Site Plan and Comps. 2014-04-28 err► Albemarle County Service Authrity - Serving s Conserving April 28, 2014 Michael Myers, P.E. Dominion Engineering 172 S. Pantops Drive Charlottesville, VA 22911 Re: Cascadia Blocks 4-7 Dear Mr. Myers: The plan, entitled "Final Site Development Plan for Cascadia Blocks 4-7" dated April 20, 2013, last revised, April 23, 2014, is hereby approved for construction. One set of the approved plan is enclosed for your records. Any previously approved plans are voided with this approval. This approval is for basic compliance with the General Water & Sewer Construction Specifications of the Albemarle County Service Authority (ACSA) and does not relieve the contractor from responsibility for his work as it relates to the plan and specifications. The ACSA requires that a copy of the approved construction plan be on the job site. The contractor is responsible for marking up a copy of the approved construction plan showing as-built information and providing this data to your client at the completion of utility installation. The final as-built plan shall be submitted in a format of one paper copy and one mylar copy. A preconstruction conference shall be scheduled with the project manager to ensure coordination and answer any questions. This will be a short meeting to review the project, materials, test methods and schedule, in order to expedite construction. Please have the proper party call me at 977-4511 to schedule the meeting. This approval is valid for a period of 18 months from this date. If construction is not in progress at the end of this time period, the approval shall be void. The contractor shall be responsible to comply with the no-lead regulation regarding brass fittings that is effective on January 4, 2014 (Senate Bill 3874 which amends the Safe Drinking Water Act). 168 Spotnap Road • Charlottesville, VA 22911 • Tel (434) 977-4511 • Fax (434) 979-0698 www.serviceauthority.org ..r (The pressure for water may exceed 80 psi at some meter locations). If you have any questions, or if we can be of assistance, please give us a call at (434) 977-4511. Sincerely, Michael Vieira, P.E. Civil Engineer MV:dmg cc: Charlie Armstrong ACSA, Alexander J. Morrison State Health Department Va. DEQ Current Development, Bill Fritz Bldg. Codes &Zoning Services Soil Erosion Inspector 050601 MyersCascadiaLtr042914 WATER DATA SHEET Date JUNE 5, 2013 (1) Project Name CASCADIA SUBDIVISION (2) Project Location INTERSECTION OF FONTANA AND DELPHI DRIVE (3) Consultants DOMINION ENGINEERING (4) Sources SOUTH RIVANNA RESERVOIR (5) Design Population 145 RESIDENTIAL LOTS @ 270 GPD = 39,150 GPD (6) Hydraulic Capacity TO BE PROVIDED (7) Pipe Material D.I.P. (8) Pipe Diameter (Inches) Length (Feet) 4" N/A 6" 670 $" 4636 10" N/A 12" N/A (9) Fire Hydrant Assemblies 11 (Number) (10) Valves: (A) Gate 27 (Number) (B) Air Relief 1 (Number) (11) Fittings: (A) Cross 0 (Number) (B) Tee 20 (Number) (C) 90° Ell 0 (Number) (D) 45° Bend 1 (Number) (E) 221/2 Bend 4 (Number) (F) Reducer 0 (Number) (G) Blow-off Assemblies 2 (Number) 20 psi available (12) Minimum pressure at critical water meter (20 psi required) Authority Provide: Booster Station Storage Reservoir A-1 `r.r Nome SEWER DATA SHEET Date JUNE 5, 2013 (1) Project Name CASCADIA SUBDIVISION (2) Project Location INTERSECTION OF FONTANA AND DELPHI DRIVE (3) Consultants DOMINION ENGINEERING (4) Waste Treatment Facility MOORE'S CREEK WWTP (5) Design Population 145 RESIDENTIAL UNITS (Number) (6) Connections 145 (Number) (7) Industrial Waste N/A (8) Pipe Material PVC, D.I.P. (9) Pipe Diameter (Inches) Length (Feet) 6" N/A 8" 4,475 10" N/A 12" N/A 15" N/A 18" N/A 21" N/A 24" N/A TOTAL FEET 4,475 (10) Manholes: (A) Standard 32 (Number) (B) Drop 1 (Number) (11) (A) Siphons & Pump Stations N/A (Number) (B) Force Main (Size-Length) N/A (Feet) Authority Provide: Drainage Basin Sub Drainage Basin A-2