HomeMy WebLinkAboutARB201500040 ChecklistRESUBMITTAL REVIEW CHECKLIST
PROJECT #/NAME: ARB 2015 -40, Stellar Sign
04 -16 -15
Previous ARB Comment
04 -16 -15 Review
X
The channel letter wall sign in the photo- rendering is out
OK
of scale (too small). Revise the photo- rendering to show
the channel letter sign at the correct scale in the
rendering.
X
Revise the channel letter sign drawing to:
1. Include the existing cabinet sign. Add a note
OK — done
indicating it is existing and to remain.
2. Show the top and bottom limits of the 36" tall
OK — done
sign band.
1. Indicate the distance from the top of
the channel letter to the top of the
OK - done
sign band and from the bottom of the
cabinet sign to the bottom of the sign
band.
2. Indicate the distance between the top
of the cabinet sign and the bottom of
OK —done
the channel letter sign.
X
Regarding the wall cabinet reface on the side elevation,
OK - done
revise the drawing to state "The background is opaque;
only the text and graphic shall illuminate."
SIGN REVIEW CHECKLIST with REFERENCES — Wall Sign, Single Business
ARB 2015 -40, Stellar
04 -09 -2015
REF
CHECKLIST ITEM
NOTES
TYPE
•
9.b
For internally illuminated signs, channel lettering
OK — channel letter with graphic
(mounted on a raceway or individual letters) is preferred to
cabinet signs.
•
5.b
When channel letters cannot be adequately accommodated,
N/A
internally illuminated cabinet signs may be considered.
•
6
Reader boards are discouraged.
None proposed
MATERIALS
•
4.c
Materials used in the sign should complement the building
OK
being served by the sign.
COLOR
•
4.e
Color for raceway- mounted channel letters, the raceway
OK — noted on drawing
shall match the wall color.
Sign colors must be harmonious with each other.
OK —
Face: Red PMS 187
Trim cap /returns: Bronze
Sign colors must not clash with the site, when viewed in
OK
daylight and at night.
Overly intense color, (such as dayglo or fluorescent
OK
colors), are prohibited.
Use of three colors or less (black and white considered as
OK
colors)
Additional colors may be approved if they contribute to the
sign balance /unity.
SIZE, SCALE, PROPORTION, AND LOCATION
•
4.b
I Signs may not exceed the size, height and setback
OK — per S. Wright
REF
CHECKLIST ITEM
NOTES
requirements as outlined in Section 4.15 of the Albemarle
35 ft proposed - 37 sq ft max allowed
County Zoning Ordinance (unless sign has a variance).
tenant needs to apply for a zoning clearance
•
Appendix
A ratio of 1/3 text to 2/3 wall area or 1/4 text to 3/4 wall
Issues:
A.A
area is a good working proportioning system for placing a
. Photo- rendering not too scale (undersized)
sign.
• Proposed letter height same as existing letter
height — which crowds sign band — allow because
this is a "reface ".
• Sign drawing needs to show (to scale) edge of
sign band — with dimensions. Include dimensions
of clearance top, bottom and between cabinet
sign and channel letter.
• Drawing needs to include the existing tagline
cabinet (dimensioned) — showing space between
rows of text
•
Appendix
Color, form, surface pattern, shape, and disposition of
Noted
A.A.4
elements and openings in an architectural design can affect
our perception of scale and can impact the appearance of a
sign on a building.
•
9.d
The wall sign's size must coordinate with the architectural
Overcrowded but permitted since it is a reface
element's size.
The sign should not over -crowd the architectural element,
Overcrowded but permitted since it is a reface
the wall, or the sign area.
Buildings and building elements should not be used as
OK
billboards.
•
9.a
Wall signs must integrate with the building's architecture.
OK
The sign placement should not obscure architectural
OK
features or details, (such as cornices, windows, columns,
pilasters and paneling).
REF
CHECKLIST ITEM
NOTES
X
9.d
An appropriate height for channel letters in a 30" high sign
N/A
band is 18 ".
This allows 6" of unoccupied space above and below the
letters.
4" of clear space above, below, and to the sides of a
channel letter sign is considered a minimum, with larger
clearances required for larger sign bands.
Degree of visibility, the distance from the Entrance
Corridor, and the architectural design of the building /area
will determine sign size, placement, and proportions.
X
4.d
Lettering should be in proportion (font size and typeface
Overcrowded but permitted since it is a reface
style) to the sign and the building.
Use of three typefaces or less.
OK— I
Additional typefaces may be approved if they contribute to
N/A
a balanced /legible /unified sign design.
X
9. e. iv
The width of the outline must be in proportion to the width
None proposed
of the letter.
An outline width of 1/8" has been found to be an
appropriate sign dimension.
TRADEMARKS, CORPORATE LOGOS AND GRAPHICS
X
4.f
The ARB may require that the color and scale of standard
OK
templates for trademarks, service marks, corporate logos
and graphics be modified.
When used, trademarks, service marks, corporate logos
OK
and /or graphics should be incorporated as an integral part
of the overall sign.
X
5.a
External (or no) illumination is preferred for approved
OK — internal
graphics /logos;
X
5.b
internal illumination may be considered for approval on a
OK - internal
REF
CHECKLIST ITEM
NOTES
case -by -case basis.
LIGHTING
•
9.e.i
External (or no) illumination is preferred for wall signs.
OK — internal lit channel letter
•
5.f
Any internal illumination is considered to contribute to
visual clutter and will be limited.
OK
•
5.c
Internal illumination design approval will be evaluated on
size, balance, complexity, and distance from the Entrance
Corridor.
OK
•
9.e.iv
The backgrounds of such cabinet signs must be made
opaque (zero light transmission).
None proposed
•
5.e
External illumination should be shielded and not create
glare.
None proposed
All external light sources shall be white.
•
9.ii
Sign lighting (external) should be shielded so that it
illuminates only face of the sign and does not shine beyond
the edge of the sign.
•
93ii
Channel letters with translucent faces must have no light
spilling outward from the top, bottom, sides or back.
OK
Faces and returns of channel letters shall be opaque when
back -lit (halo -lit).
N/A
•
9. iv
Cabinet signs shall have a non - illuminated background, or
an opaque (zero light transmission) background.
None proposed
Cabinet signs shall be constructed such that no light spills
outward from the top, bottom, sides or back.
•
5.g
All illumination shall be non - blinking.
None proposed
•
5.h
An exposed light source that forms the body of a sign,
(such as exposed neon signs), shall not be used in the
None proposed
REF
CHECKLIST ITEM
NOTES
__4Entrance
Corridors.
ARB ACTIONS
X
If LED lighting is proposed the sign drawing must state
OK — note on drawing
The level of illumination provided by the LED lights will
not exceed the illumination produced by a single stroke of
30 milliamp (ma) neon.
X
Red acrylic #2283 has been determined to be an
OK —Red PMS 187
inappropriate color for signs.
Pantone color match for 2283 is 485C.
Red 42793 has been approved as an acceptable substitute.
Pantone color match for 2793 is 187C.
X
ARB
Visual clutter resulting from adjacency, for example at the
OK
Action
Hardee's locations, is a reasonable basis for not allowing
Memo:
illumination of the graphic.
5/7/12