HomeMy WebLinkAboutSDP201500017 Review Comments Final Site Plan and Comps. 2015-06-17�'IRGII�ZP COUNTY OF ALBEMARLE Department of Community Development 401 McIntire Road, North Wing Charlottesville, Virginia 22902 -4596 Phone (434) 296 -5832 Fax (434) 972 -4126 May 27, 2015 Rev1: June 17, 2015 Craig Kotarski, P.E. Timmons Group 919 2nd Street SE Charlottesville, VA 22902 RE: SDP201500017 Western Albemarle H.S. (Environmental Studies Center) — Major Amendment Dear Sir: Your Major Amendment application has been reviewed. In order for the amended site plan to be approved the following revisions are required: 1. [32.5.2(a)] Add EC (Entrance Corridor) to the Zoning information. Rev1: Comment addressed. 2. [32.5.2(a)] Provide an exhibit showing the location of the proposed work on the subject parcel, and the name of the owner(s), zoning district, tax map and parcel numbers and present use of abutting parcels. Rev1: Comment addressed. 3. [32.5.2(a)] Provide a dimension from the proposed work to the nearest boundary line. Rev1: Comment addressed. 4. [32.5.2(d)] County GIS shows a small area of critical slopes just off the eastern edge of the parking lot that appear to be impacted by the proposed work; an exception may be required. It looks as if field -run topography information was provided for this project; clarify if this topo information also indicates the presence of critical slopes in this area and show them on the plan, if necessary. If there are critical slopes present, we will have to determine whether or not the slopes were lawfully created by a development plan that was approved by the county to know if an exception is required. Rev1: Comment not fully addressed. Label the areas of critical slopes. The only impact to the slopes shown on the plan is the installation of silt fence; is any other impact proposed? If so, provide the SDP application number of the County approved plan that created the slopes or apply for an exception. 5. [32.5.2(j,k,l)] Verify that the location(s) and dimensions of all existing or proposed utilities and utility easements including water, sewer, drainage, telephone, cable, electric and gas are shown on the plan. Provide the Deed Book and Page reference for any existing easements. Any proposed easements should be labeled with the intended owner. Rev1: Comment addressed. 6. [32.5.2(n)] GIS shows two additional structures in the area where this work is proposed; clarify whether or not these structures exist. Rev1: Comment addressed. 7. [32.5.2(n)] Provide the maximum footprint of the proposed building. Total square footage has been provided, but footprint has not. Rev1: Comment addressed. 8. [32.6.2(i)] List the number of parking spaces removed and the total number remaining. Since the parking requirement for schools is generally specified by parking determination, verify with Zoning that the parking requirement is still satisfied with the proposed reduction in spaces. Rev1: Comment not fully addressed. Clarify if Zoning verified that the parking requirement is still satisfied. 9. [32.6.2(i) & 4.12.15(f)] The end of one parking row is not protected by a raised island, only paint striping; verify with Engineering that no raised island is needed. Rev1: Comment addressed. 10. [32.6.20) & 32.7.9] This plan proposes the removal of two existing trees with no documentation of whether or not these trees were planted to meet landscape requirements on previous site plans. Please either document that these trees were not required by any previously approved site plan or provide two equivalent trees to replace those that are being removed. Rev1: Comment addressed. 11. [32.6.2(k) & 4.17] Is any outdoor lighting proposed? If so, all lighting (including bollards and building mounted fixtures) must be shown on a lighting plan that includes a photometric plan, luminaire schedule and cut sheets for each proposed fixture. Rev1: Comment addressed. 12. [Comment] This amendment cannot be approved until all comments from the Site Review Committee (SRC) have been addressed. Any comments not available at the time of the SRC meeting will be forwarded once received. Rev1: Comment not fully addressed. Engineering has reviewed the revision submittal and has no objection. ACSA review is pending; comments, if any, will be forwarded upon receipt. Staff has provided references to provisions of Chapter 18 of the Code of the County of Albemarle. The Code is kept up to date by the County Attorney's office. The Code may found on the County Attorney's website which may be found under "Departments and Services" at Albemarle.org. In accord with the provisions of Section 32.4.3.5 of Chapter 18 of the Code if the developer fails to submit a revised final site plan to address all of the requirements within six (6) months after the date of this letter the application shall be deemed to have been voluntarily withdrawn by the developer. If you have any questions about the comments please feel free to contact me. Sincerely, &-L ('. eab Ellie Carter Ray, PLA Senior Planner Planning Division