Loading...
HomeMy WebLinkAboutSUB201500066 Approval - County Preliminary Plat 2015-05-29�� ' •mow. r COUNTY OF ALBEMARLE Department of Community Development 401 McIntire Road, North Wing Charlottesville, Virginia 22902 -4596 Phone (434) 296 -5832 Fax (434) 972 -4126 May 29, 2015 Justin Shimp Shimp Engineering 201 E. Main Street Charlottesville, VA 22902 RE: SUB2015 -066 Wayland's Ridge- Preliminary Plat Mr. Shimp: The Agent for the Board of Supervisors hereby grants administrative approval to the above referenced subdivision plat. This approval shall be valid for a period of five (5) years from the date of this letter, provided that the developer submits a final subdivision plat for all or a portion of the site within one (1) year after the date of this letter as provided in 14 -226 of the Subdivision Ordinance of the County Code, and thereafter diligently pursues approval of the final subdivision plat. The final subdivision plat will not be considered to have been officially submitted until the following items are received: 1. A final subdivision plat that satisfies all of the requirements of 14 -226 of the Subdivision Ordinance. 2. A fee of $1,230. Please submit eight (8) copies of the subdivision plat to the Community Development Department and three (3) copies directly to ACSA. The assigned Lead Reviewer will then distribute the plans to all reviewing agencies. Once you receive the first set of comments on the final subdivision plat, please work with each reviewer individually to satisfy their requirements. The final subdivision plat will not be approved until the following conditions are met: The Department of Community Development shall not accept submittal of the final subdivision plat for signature until tentative approvals for the following conditions have been obtained: Planning Division Approval of (2 copies): 1. A subdivision plat meeting the requirements of 14 -226 2. [Section 2.2.3 Open Space; 4.7 Open Space Requirements] Cluster developments (Lots less than 30,000sf) require a minimum of 25% open space. Not more than eighty percent of the open space can be located within the flood plain. If open space is not provided, lots must be a minimum of 30,OOOsf and have a minimum frontage of 100 feet. ,imitation on certain elements. If open space is required by this chapter, not n-iore than eighty (80) percent of the rnininuun required open space shall consist of the following: (i) land located within the one- hundred year flood plain_ (ii) land subject to occasional, common or ffi-quent flooding as defined in Table 16 Soil and 'Water Features of the Uluted States Departinent of Agriculture Soil Conservation Ser4'ice, Soil Sui -vey of Albemarle County, Virginia, August, 1985; (iii) critical cT presen-ed slopes; and (iv) land devoted to stonnt�ater amnagenient facilities or flood control devices, except where the facility or feature is incorporated into a permanent pond, lake or other water feature deemed by the agent to constitute a desirable open space anieruty. 3. [Density Bonus] For the maintenance of wooded areas: Show where the areas are and provide a conservation plan. The wooded areas must meet the definition in order to qualify (see below). Also, state the calculations in the Area Summary table. The wooded areas must be outside of the dedicated land to the County, as well as, not within the proposed lots in order to assure maintenance. Mooded area, forested m-ea: An area contaniing one of the ruin u n munber of trees of specified size; or combinations thereof, from the following table: Diameter of Tree Per Per One- at Breast Heist Acre Half Acme 3.0" - 4.9" 60 30 5.0" - 6.9" 38 19 7.0" - 8.9" 22 11 9.011- 10.9" 14 7 11.0 " -129" 10 5 13.0" - 149" 7 4 15.0 "+ 5 3 4. [Density Bonus] For the street trees: no easement is shown along the proposed roads, provide the easement. Show the trees and provide the required information per 32.7.9. 5. [Density Bonus] The park land to be dedicated must be approved by the Board of Supervisors. It was advised that the applicant take the proposal to the CCAC, did this occur? What was the feedback from that meeting? If this has not been to the CCAC, coordinate with me so that I can attend. 6. [14- 302(A)(3)] It appears that the right of way for Road 'B' will be extended to the property lines, will this be dedicated to public use? If so, state "dedicated to public use" and state the width. Also, the proposed cul -de -sacs are outside of the right of way. They should be within the right of way. 7. [14 -422] Sidewalks must extend all around the proposed cul -de -sacs. Also, it appears that the cul -de -sac is not within the right of way. Revise to have the cul -de -sac within the right of way. S. [14 -422] It appears that the proposed property lines are within the proposed sidewalks and landscape strips. The landscape strips and sidewalks need to be within the right of way. 9. [14- 302(A)(7)] Show the existing property lines. This proposal is made up of two separate parcels which must be shown, and if combining show the boundary line adjustment land hooks. 10. [14- 302(A)(12)] The entrance is located within the preserved slopes, however the entrance may need to be moved to provide less impacts to these slopes. Provide the information required by VDOT to determine if the entrance is located in the best possible location and cannot be moved to the south to lessen the impact. C. Necessaiypifblic facilities_ Public facilities necessary to allow the use of the lot, provided that the lot does net contain adequate land area outside of the preserved slopes to locate the public facilities and one Or more of the following exist: (1) the laud disturbing activity avoids impacts on other protected resources such as stream buffers or floodplai -, (n) the alignment of the public facilities is consistent with the alignment of public facilities depicted Or described ui the comprehensive plan; (iii) the disturbance is necessary to provide interconnection required by the Code or the applicable regulations of other public entities; or (iv.) prohibiting the facilities from being located on preserved slopes will cause an unnecessary hardship_ To the extent that public facilities are established on preserved slopes, the preserv. ed slopes should be preserved to the lnaxinnuli extent practicable consistent xv-ith the intent and purpose of this overlay district. 11. [14- 302(A)(14)] On the front cover it states that 4.56 acres dedicated to Albemarle County. Does this include the park dedication and the right of way? If so, separate out the two. If it is only intended to be the park area, then clarify if the dedication is 4.56 acres as stated on the front cover, or 1.6 as stated on sheet 2. 12. [14- 302(B)(7)] State that the property is within the Lickinghole Creek water supply watershed. Please contact Megan Yaniglos at 296 -5832 ext 3004 if you have questions or require additional information. Engineering Division Approval of (1 copy of subdivision plat; WPO and Road plan number stated in application): 1. Entrance is crossing preserved slopes. This is okay without a rezoning if we find there is no reasonable alternative. Confirm with VDOT. 2. Verify the ditch line is running north adjacent to Crozet Ave. I recommend this resolved now so you are not proposing a grass swale next to another ditch. This will impact design of the channel to the biofilter. Also, clarify how the pipe outlet at entrance will be conveyed into the grass channel. It appears to be uphill. 3. Provide more backyard for lots 4 -6. Cut slope back. 4. Clarify grading and drainage for lots 10 -15 and 17 -19. It appears runoff will flow towards homes and into the garage. Are you providing trench drains at end of driveway before the garage? Driveway grading should be away from garage and pitched to one side. This is typical construction. For example lot 10 and lot 20 with a crown does not work well. Revise. 5. Clarify type of dwelling. This may help resolve comment #4. 6. Grass channel is a BMP facility. This should be off lots. Create a special lot or show in open space for grass channel. Another option is to provide a normal swale just to convey runoff with inlets at every 3 lots. This will not be counted for quality. 7. Label road as public. 8. Show conceptual pre- treatment area. This is to verify you have enough room for BMP. 9. Engineering Review Comments Page 2 of 2 10. Location of biofilters will work better on the other side of the road. I recommend to relocate. I also recommend resolving this at the preliminary stage to verify there is enough room for the BMPs with the proposed number of lots. 11. Otherwise, address concerns listed below prior to the approval of the preliminary plat: a) Verify there is enough room for the embankment. b) The standards states no more than 1' ponding for biofilters. In cases of larger storm events verify that it can bypass biofilter. Runoff should not overtop embankment and spill into road B. c) Avoid short circuiting. See location of pipes into biofilter. 12. Both future extensions will need to be verified by planning to clarify how the R/W should be shown around the cul -de -sac. Address for Final Subdivision Plat: (Additional comments may be added or eliminated based on further review) 1. Lot 10 -16 driveways should not exceed 16% 2. Proposed contours should be 2' contours. 3. Show CG -6 around cul -de -sac to avoid runoff towards retaining wall. 4. Show retaining wall design. Any walls supporting roads require engineered plans (not generic manufacturer's details) and computations. 5. Verify classification of trail and provide a detail that meets Albemarle County Design Standards. Trails should be in common areas, and maintained through neighborhood covenants or private agreements. When not in common areas, all trails are required to have easements, which must be a minimum of 10' wide. Concentrated runoff must not run across the trail and where a nonpaved surface is used, trail breaks and erosion prevention measures must be used on grades above 7% to prevent repeated washout of the surface. 6. Provide outlet protection at the end of culverts from biofilter. Please contact Michelle Roberge at 296 -5832 if you have questions or require additional information. ACSA approval to include (3 copies): Final Water and Sewer plans are required for review and approval by the ACSA. Please submit 3 copies of the plan, a water data sheet and a sewer data sheet to the attention of Jeremy Lynn, PE. RWSA Capacity Certification will be required. RWSA review and approval of the sewer connection will be required. Please contact Alex Morrison at 977 -4511 ext 116 if you have questions or require additional information. E911 approval to include (1 copy): 1. The applicant should contact this office with a list of three (3) proposed road names for approval before final plans are submitted. Please contact Andrew Slack at 296 -5832 if you have questions or require additional information. Fire & Rescue approval to include (1 copy): Based on plans dated 4/6/15 1. Cul -da -sac's shall be 96 ft FC /FC. 2. Radii shall have a minumim radii of 25 ft. 3. Road's A & B shall be marked No Parking on one side. 4. Fire hydrants shall be located on a spacing of 500 ft per travelway. 5. Fire Flow test required before final approval. Please contact Robbie Gilmer at 296 -5833 if you have questions or require additional information. RWSA approval to include (1 copy): General Project Comments 1. A sewer Flow Capacity Certification will be required prior to final site plan approval. Sheet C2 of 2 4 1. The existing RWSA 15" VCP sanitary sewer line is shown incorrectly. See GIS map for approximate manhole locations. 2. Show the existing RWSA permanent sanitary sewer easement (30' wide, D. B. 829 P. 041) Please contact Victoria Fort at (434) 977 -2970 ext. 205 if you have questions or require additional information. VDOT approval to include (2 copies): 1. A line of sight profile should be provided at the intersection of Road "A" and Crozet Ave. to ensure adequate sight distance. 2. Right and left turn lane warrants should be provided. 3. The entrance onto Crozet Ave. should be designed to meet Appendix B (1) of the Road Design Manual. A 12' offset and 4:1 taper should be provided, similar to the "Commercial Entrance Designs Along Highways with Shoulders ", figure 4 -9, in Appendix F of the Road Design Manual 4. Entrance radii should be labeled. 5. The curb and gutter should be graphically shown on the plan view on sheet 2. 6. A minimum 45' radius should be used if a school bus is expected to use the cul -de -sac. We recommend coordinating with Emergency Services and Albemarle Engineering Staff. The following comments should be addressed in the Road Plan submittal: 1. A line of sight profile should also be provided at the intersection of Road "A" and Road "B" to ensure a clear line of sight. 2. Road /waterline profiles, storm profiles, storm computations and sanitary sewer profiles should be provided for review. 3. The waterline will need to be located outside of the wheel path. 4. The stormwater management plan and the erosion and sediment control plan should be submitted for review. This may be submitted separately. 5. A permit will be required for the street connection as well as the waterline connection under Crozet Avenue. Where pavement exists, the permittee shall bore, push, or jack and maintain minimum cover of 36 inches. 6. A Maintenance of Traffic Plan (MOT) will be required with the road plan submittal. 7. Additional comments may be generated during the Final Site Plan review. Please contact Shelly Plaster at (434) 422 -9894 if you have questions or require additional information. If you have any questions about these conditions or the submittal requirements please feel free to contact me at Extension 3004, myaniglos @albemarle.org. Sincerely, Megan Yaniglos Principal Planner 5