Brian,
SWM Plan -1 item required for VSMP/WPO Approval. Engineering can approve VSMP /WPO Application, provided:
( "The pollutant removal requirement of 0.33 lb /yr will be purchased from a nutrient bank. ")
E Domwealat n of �bt .tppbl &W% Acqutttliun qUatilnew cleikty "I be V1 n so Or? V$,My mollop in, 1(14 the
DgPWMM [ M.2 cat:Ficetu►n fM)U 1IM ctr4d prcr,xm d+an"11eulutg the tUMItai aV14asphams nurimit cAvdltl
AC41INFe+i +md 1he:i%EAk i- _d rimoofnhrrofev uaa•TMI11 trteh?%al 1be [78dH-TM_ -MIMg tnurr Lut11 lilt tffCMtt flare
9tr:20alwit '. t- tnb1i --hseeg Applltiabou itrp lu i1ccv2 ,t411ceRsdl § J. ;-1e 19� #:. steer la edo tm-t.I uics al tail ;V). Ow
Depu=1mit I v.-MI= q►1s101. a ;a incrawtu fe+e eqtra1 ro $.m P=4Cslr of the shm"U i< p3u4 V- eht appltc rua lfar xhr es edtis
Suet tee shall be .tep4' Test wo the Vatoun Sr.�nuwm r MaaAff hhu±at Find MAUL W ION' � i 1 -41 ' S -'3
SWPPP (4 items, 5t1i item/favor). Engineering can approve VSMP/WPO Application for this project, provided:
1. By p. 17 of SWPPP, Index of Appendices, please provide SWPPP Certification Statement nearly identical with
signature certification on VPDES Permit Registration Statement (see p. 22/122 p. SWPPP) — provide SWPPP
Certification identical with:
4, Certification, Arty person signing a document under Part Ili K I of 2 shall make the fallowing
Certification.
"I certify under penalty of law that 1 have read and understand this dDwfnerlt and that This document
and all attachments were prepared m accordance with a system designed to assure that qualified
personnel prope(ly galtlenW and evaluated the information submitted. Based on my inquiry of the
pori5on or persons who manage the system, or those persons directly raspunsible for gathering the
information, the information suit rnitW iS, to the test of my hn"Iedge Ond belief, true, accurate, and
complete_ I am aware that there ere Signifi nt pen$Ities for submtiting false Information. Ind uding tine
passibility of Fine and imprisvnment for knowing vilolation¢."
2. Frank, please sign/date Registration Statement/General VPDES Permit —p 22/122.
3. Pg. 2 — Permit Fee Form should not be sent to DEQ, Receipts Control, Richmond, VA. Instead, please send WPO
Application to: Community Development, Attn. Todd Shifflett; 401 McIntire Rd, Charlottesville, VA 22902-
4596. Albemarle County is a Local VSMP Authority.
4. Remove p. 25 — instead use Attached (Local VSMP Authority) WPO Application. Check (p. -1 block) revision or
resubmission for review.
5. As a favor, please discuss last 2 -p. in context of site, stream, or design. Where is 50' irregular
section? Pipe? What does Pavlovskii's Method show? Velocity = Infinity (? - Explanation not required for
Approval —Very basic /just curious).
Ci1F Output Data
Lfps"am Depll+
0.40
It
Profile Descdpticn
Profile Headlong
0.00
It
Downstream Velocity
Infinity
itrs
Upgiream Velocity
Infinity
[us
Normal Depth
1.57
It
Critical Depth
1,85
It
Channel SlaW
D_04500
Mt
r,l,cat Staoe
D,01898
W1
Thanks, Brian
434.296 -5832 —x3069
From: brian.mcpeters @kimley- horn.com [mailto:brian.mcpeters @kimley- horn.com]
Sent: Wednesday, July 08, 2015 9:01 AM
To: John Anderson; Frank Pohl
Cc: matt.harrell @kimley- horn.com
Subject: RE: Planning Application Review for WP0201500021 Crozet Avenue North Sidewalk Project.
Importance: High
ShareFile Attachments
Title Size
CrozetNorth_SWPPP.pdf 8.3 MB
W P0201500021 _Crozet- Ave- N_Sidewal k_050515. pdf 457.7
KB
Download Brian McPeters uses ShareFile to share documents securely.
Attachments Learn More.
John,
Please see the revised SWP3 for the above WPO application. Please let me know, if we've adequately addressed your
comments. We anticipate the Contractor needing to pull a Land Disturbance Permit in late August, so your review
would be much appreciated!
Feel free to call me to discuss.
Thanks,
4
Brian A. McPeters, PE
Kimley -Horn 11700 Willow Lawn Drive, Suite 200, Richmond, VA 23230
Direct: 804 - 672 -4721 1 Mobile: 804 - 539 -1032
Connect with us: Twitter I Linkedln I Facebook I
Celebrating eight years as one of FORTUNE'S 100 Best Companies to Work For
From: John Anderson [mailto:janderson2 @albemarle.org]
Sent: Tuesday, May 05, 2015 12:18 PM
To: McPeters, Brian; Frank Pohl
Subject: Planning Application Review for WP0201500021 Crozet Avenue North Sidewalk Project.
The Review for the following application has been completed:
Application Number = WP0201500021
Reviewer = John Anderson
Review Status = Denied
Completed Date = 05/05/2015
Thanks for your patience.
Comments available, CV system.
434.296 -5832 —x3069
YlAGIl`11A
County of Albemarle
Department of Community Development
VSMP Permit plan review
Project:
Crozet Ave North Sidewalk Project
Plan preparer:
Brian A. McPeters, P.E., Kimley -Horn / 1700 Willow Lawn Drive, Suite 200,
Richmond, VA 23230 — brian.mcpeters(&kimley- hom.com
Owner or rep.:
Frank Pohl, Office of Facilities Development, Albemarle County
401 McIntire Rd/Room 228, Charlottesville, VA 22902 — fpohlkalbemarle.org
Plan received date:
3 Apr 2015
Date of comments:
5 May 2015
Reviewer:
John Anderson
Comments are MINOR in nature —may submit .PDF /s for preview /conditional approval. Please do not revise
hard copy SWPPP (inserts /exhibit) prior to .PDF (follow -up) review of inserts /exhibit —this may save time.
A. Stormwater Pollution Prevention Plan (SWPPP)
The SWPPP content requirements can be found in County Code section 17 -405. A SWPPP must contain (1)
a PPP, (2) an ESCP, (3) a SWMP, and (4) any TMDL measures necessary.
1. Albemarle County must sign/date Registration Statement (ACCD/Engineering will coordinate).
2. Provide SWPPP Certification statement (VAR10, Part III, K.4.):
4. Certification. Any person signing a document under Part III K 1 or 2 shall make the following
certification:
"I certify under penalty of law that I have read and understand this document and that this document
and all attachments were prepared in accordance with a system designed to assure that qualified
personnel properly gathered and evaluated the information submitted. Based on my inquiry of the
person or persons who manage the system, or those persons directly responsible for gathering the
information, the information submitted is, to the best of my knowledge and belief, true, accurate, and
complete. I am aware that there are significant penalties for submitting false information, including the
possibility of fine and imprisonment for knowing violations."
3. SWPPP is comprehensive. However, please update insert sheets to reflect revisions per ESC plan
comments, Sec. C. below.
4. CE -101 or CE -102 —Show initial locations of. sanitary /porta john; concrete wash -out draining to
pit/area with impermeable lining; vehicle wash draining to sediment trap /equivalent; on -site fuel
storage /re- fueling areas with containment (if proposed); non - hazardous solid waste dumpster (if
provided); covered /protected paint - solvent storage (if present). Note: these PPP facility locations
are required to be shown on SWPPP exhibit, not full -size ESC plans. These locations may change
as needed (if revise locations, show via pencil edits to on -site SWPPP exhibit).
5. Future Reference (or additional sidewalk projects: State Farm Blvd; Barracks Rd; Hydraulic Rd), please:
a. Number pages of document for ease of reference.
b. Runoff coefficients (Rational or Modified Rational Method) are not used for compliance.
Use NRCS /TR -55 /curve numbers instead. —ref 9VAC25- 870 -72 (24 -hr storm/NOAA
Atlas 14).
Engineering Review Comments
Page 2 of 4
B. VSMP: SWPPP: Stormwater Management Plan (WP0201500021)
VSMP Regulation 9VAC25- 870 -108 requires the VSMP authority to approve or disapprove a SWMP. This
plan is disapproved for reasons provided in comments below. The stormwater management plan content
requirements can be found in County Code section 17 -403.
Drainage and ESC Narrative for: Crozet Avenue North Sidewalk Improvements Project (REPORT),
27- Mar -15, Water Quality Sec. explains: "The pollutant removal requirement of 0.33 lb /yr will be
purchased from a nutrient bank." Two items:
a. Ref. 9VAC25- 870 - 69/62.1- 44.15:35 — Documentation of acquisition of credits required.
(https:Hlegl.state.va.us /c ip bin/legp504.exe ?000 +cod +62.1- 44.15C35).
E- Documentation of the applicant's acquisition of nutrient credits shall be provided to the VSNP authority and the
Department in a certification from the credit provider dornmenting the number of phosphorus nutrient credits
acquired and the associated ratio of nitrogen nutrient credits at the credit- generating entit},. Until the effective date
of regulations establishing application fees in accordance vath § 62.1 - 44.19:20, the credit provider shall pay the
Department a tinter quality enhancement fee equal to six percent of the amount paid by the applicant for the credits -
Such fee shall be deposited into the Virginia Storrnwater Management Fund established by § 62.1 -44.15:29 -
b. Report TOC indicates Appendix D contains Water Quality Calcs. Appendix D lists data.
Provide calculations (VSMH11999 Vol. II, Appendix 5D Worksheets /situation 3).
2. Report/MS -19 Compliance — Provide pre- /post - development Qto values /calculations.
C. VSMP: SWPPP: Erosion Control Plan (WP0201500021)
Virginia Code §62.1- 44.15:55 requires the VESCP authority to approve or disapprove an ESCP. This plan is disapproved
for reasons provided in comments below. The erosion control plan content requirements can be found in County Code
section 17 -402.
1. Please remove the following sheets from ESC/VSM Plans (site, road, traffic): CA -002A, CR -102,
CT -101, CT -102, CT -500, CT -501, CT -502, X01, X02, X03.
2. CA -004: Revise uppermost Crozet Ave detail label to read Sta. 10 +00 to Sta. 15 +65.28.
3. CA -004: Please clarify if symbols 7 and 8 relate to sidewalk. Also, furnish a more descriptive
Sidewalk Detail.
4. CA -004 —If Inset B is for sidewalk, symbols 10 and 11 are undefined (should these read 7 and 8 ?).
For clarity, please provide a more readily readable sidewalk detail; for example:
W = 5 fl desirable
7 in_ min. next to roll tap curb
r 4 in. min. elsewhere
votty Space
3 a min
6 It min w Irk
Plant line, g florin
I
I
I
" II the utility spaoe Is paved, constructlon shall be on compacted subgrade and the thickness
shall match that of the sidewalk, however, the area wl II not be considered part of the minimum
width required for sidewalk.
It trees are planted in paved pedestrian areas, they shall be planted in tree wells that include
a planting grate, approved by the resident engineer. However. the width of sidewalk passing
the tree well shall be at least 3 feet in width.
FIGURE B — DETAIL BACK OF CURBS
Link: htt p : / /www.viriziniadot.oriz/business /resources /gpl2endb.pdf
Engineering Review Comments
Page 3 of 4
5. CE -101 — Include General construction notes for Erosion and Sediment Control Plans (1. -20.); link:
http:/ /www.albemarle.orgLupload/images /forms center/ departments /Communiiy Development/for
ms/En ing eeringtand WPO Forms /En ing eerina Plan Review General Notes Feb20l4.pdf.
6. CE -101 —Add Note: Leave a gap in CIP woven fabric for stream to pass.
7. CE -101 — Revise Legend and Erosion Details to include paved construction entrance (PCE).
8. CE -101 —Show elevation (contours) at construction entrance /CE. Extend contours beyond ESC
measures, to aid plan review.
9. CE -101 — Contour elevation labels are unreadable. Add readable labels.
10. CE -102 — Revise per CE -101 comments, as necessary.
11. CE -501 — Revise Paved Wash Rack detail, so readable (Attached detail).
12. CE -501 — Management Strategies and Sequence of EC Measures/Note 13: Revise consistent with
Note 10, CE -102 (County ESC inspector concurrence required).
13. CE -501 — Management Strategies and Sequence of EC Measures/Note 11: Recommend revise
reference to periodic inspections to be consistent with inspection frequency in VAR10 /SWPPP.
14. CG -100 — Future reference: runoff coefficients used with Rational Method are not used with TR-
55/NRCS. —Also, comment #A.4.b., above. In the future, use CN, not "c."
15. CG -201 —If 18" RCP label is unintentional, remove. Meaning is unclear. —Also, next comment.
16. CG-202/CR- 10 1 (Sta. 19 +50 - 21 +00±) — Drawings present dissimilar information. Clarify (across
plan sheets) what is existing, proposed, or to be abandoned/removed. —ref images:
_dab w
400
i
i
- - — ! W __ — - -- 4F
- EXIST. R/w apt_
REMOVE STUB
g / 1 TO BE
�E, NED OUT
1S' CMP
rX
17. CR -100 —Label radius of curb, Crozet Ave. North/St. George Ave (SR 810/1202).
18. CR -101 —Add (triangle) symbol 9 to Legend.
19. CR -101 —Add Note: Exist. 4' Conc. Sidewalk to be demolished (unless existing sidewalk remains).
20. CR -101 — Provide (profile view) detail showing how 101 -5 (DI -4A) connects with 15" line, 18"
line, and 48" HDPE.
21. CR -101 — Revise schematic, Sta. 19 +50 — Str. 101 -1, consistent with CG -202. Comment #16,
above.
22. CR -101A — Identify existing structure, Sta. 20 +29.62. Label pipe type, diameter, and INV elev.
23. CR- 101A/All structures —Label pipe Material /type, L, DIA, INV elev. (in/out). Reference to plan
Engineering Review Comments
Page 4 of 4
sheet is insufficient.
24. CR- 101A —Str. 101 -3A and 101 -7: Provide MH rim elevations.
25. CR -10113 — Insufficient data: Please provide slope, L, DIA, material, INV labels (48" HDPE).
Provide equivalent labels for existing structure beneath Crozet Ave. N.
26. CR -101B —Two proposed grade labels are confusing. If one is existing grade, please revise label.
27. CR -101B — Provide Std. VDOT EW at existing pipe outfall. There will never be a better time.
28. CR -500 — Ensure all details print clearly. Ensure all table values /dimensions are readable.
29. CR -501 — Several details are unreadable. Ensure readable. Also, prior comment.
30. May have encountered reference to off -site waste area during initial review, but cannot locate
reference. If an off -site waste area proposed, ensure off -site area has an approved ESC plan.
The VSMP permit application and all plans may be resubmitted for rp eview (as .PDFs). When all comments have
been satisfactorily addressed, and if there are no additional comments, please provide 2 copies of the plans, 1 copy
of SWPPP. Encourage .PDF submittals that show revisions.
Engineering plan review staff is available 2 -4 PM on Thursdays, should you require a meeting to discuss this review.
Plan reviewer is available at 434.296 -5832 -0069 should you have any questions.
Process:
After approval, county staff will need to enter project information in a DEQ database for state application
processing. DEQ will review the application information based on local VSMP authority approval. At this time, the
DEQ portion of the application fees will need to be paid directly to the state. For fastest processing, this is done
electronically with the emails provided on the application. DEQ should notify applicants with instructions on how to
pay fees. When DEQ approves the application, they will issue a permit coverage letter. This should be copied to the
county.
After DEQ coverage is issued, via the coverage letter, the County can hold a pre - construction conference. Applicants
will need to request a pre - construction conference by completing a form, and pay the remainder of the application
fee. The form identifies the contractor and responsible land disturber, and the fee remaining to be paid. This will be
checked by county staff, and upon approval, a pre - construction conference will be scheduled with the County
inspector. At the pre - construction conference, should everything proceed satisfactorily, a joint VSMP and grading
permit will be issued by the County so that work may begin.
County forms can be found on the county website forms center under engineering;
htt2://www.albemarle.org/deptforms.asp?departrnent--cdengmMo
Contact John Anderson, Engineering Dept, if any questions. janderson2(a)a1bemarle.org / 434 - 296 -5832 x3069
Thank you.
File: WP0201500021 Crozet -Ave -N Sidewalk 050515