HomeMy WebLinkAboutWPO201500043 Action Letter 2015-07-16�pF A
vt�r�1Q
COUNTY OF ALBEMARLE
Department of Community Development
401 McIntire Road, Room 227
Charlottesville, Virginia 22902 -4596
Phone (434) 296 -5832 Fax (434) 972 -4126
Project title:
Project file number:
Plan preparer:
Owner or rep.:
Plan received date:
Date of comments:
Reviewers:
VSMP Permit plan review
Cascadia, Block 4 -7, interim plan
WP0201500043
Dominion Engineering
Cascadia Development LLC
9 July 2015
13 July 2015
Glenn Brooks, P.E.
The VSMP erosion and sediment control plan modification to allow interim measures (as final
erosion control measures have yet to be installed), or to change the final design of sediment
trapping measures, has been reviewed;
This plan is incomplete and could not be approved. The computations provided for interim SB -4 must
follow the state guidelines, which also applies to the release channel. (The plans refer to this as a basin,
but there is no riser or pipe.) The added measures along Rt. 20 to accommodate the pond outfall and ditch,
and culvert protections were not shown on the plans, and were not engineered. The phase lines drawn
through SB -2 are unexplained, and do not appear workable. Furthermore, the contractor has stated the
baffle is impossible to install in the rock bottom. The existing sediment trap removal next to northern
property boundary was not included. The stockpiles and changes to SB -3 and the adjacent trap were not
included. These areas appear to be drawn the same as on approved final plans. If the intent is to rebuild
these facilities to meet original plans, please have this commence at once.
File: E1_vsmp review projectname.doc