HomeMy WebLinkAboutSDP200800155 Review Comments Critical Slope Waiver 2015-08-03kin ��RGt2314' COUNTY OF ALBEMARLE Department of Community Development 401 McIntire Road, Room 227 Charlottesville, Virginia 22902 -4596 Phone (434) 296 -5832 Fax (434) 972 -4126 Project: Thomas Jefferson Foundation Water and Wastewater Improvements Part II Critical Slopes Application Plan (CSW) Plan preparer: Herbert F. White 111, Rob Umberger, WW Associates, Inc [3040 Avemore Square Place, Charlottesville, VA 22911, hwhitegwwassociates.net rumber ernwwassociates.net ] Owner or rep.: Thomas Jefferson Foundation, Inc. —P.O. Box 316 Charlottesville, VA 22902 Plan received date: 7 Jul 2015 Date of comments: 3 Aug 2015 Reviewer: John Anderson — RECOMMEND GRANT Critical Slopes Waiver Plan Coordinator: Sarah Baldwin Critical Slopes Waiver (SDP200800155) Note: VSMP required for Montalto Underground Water Storage Tank Site (3 Additional Water /W.Water improvement sites do not require VSMP/VESCP. Comments 1. WW Associates Letter and design (9 plan set) dated 07/06/15 offer details and descriptions of four water / wastewater improvement project sites which impact critical slopes to varying degrees: 1. Main Wastewater pump station: Natural critical slope impact estimate: 204 sf (Note: typ. parking space, 9' x 18' =162 sf). Engineering rates impact inconsequential. [Estimated impact to Man- made critical slopes: 121 sfJ 2. Pump Station A: Man -made critical slope impact -240 sf; Natural critical slope impact — 0.0 sf 3. Pump Station B: Man -made critical slope impact -240 sf; Natural critical slope impact — 0.0 sf 4. Montalto Tank primary focus: Man -made critical slope impact estimate: 4528 SF (0.1039 Ac.); Natural critical slope impact estimate: 5818 SF (0.1336 Ac.) 2. Letter and PLAN (6 -Jul 2015) consider and adequately address criteria listed at 18- 4.2.5.a.1: 1. The rapid and/or large -scale movement of soil and rock; 2. Excessive stormwater run -off, 3. Siltation of natural and man -made bodies of water; 4. Loss of aesthetic resources; and 5. In the event of septic system failure, a greater travel distance of septic effluent. Note: Engineering evaluation relative to L -5., above: Proposed grading; limited scope of impact; low - visibility improvements; plan to disconnect existing septic fields and connect to public utility; and appropriate and adequate ESC measures address listed criteria. 3. Engineering recommends (per 18- 4.2.5.a.3) that the Planning Commission grant critical slopes waiver to the listed water /wastewater improvement projects (collectively "Improvements ") since designs are not detrimental to public health, safety and welfare; to the orderly development of the area; or to adjacent properties. Designs adopt and apply sound engineering /site selection principles. At least one of the following pertains at each site, and collectively to improvements: 1. Strict application of the requirements of section 4.2 would not forward the purposes of this chapter or otherwise serve the public health, safety or welfare; 2. Alternatives proposed by the developer or subdivider would satisfy the intent and purposes of section 4.2 to at least an equivalent degree; Engineering comments Page 2 of 2 3. Due to the property's unusual size, topography, shape, location or other unusual condition, excluding the proprietary interest of the developer or subdivider, prohibiting the disturbance of critical slopes would effectively prohibit or unreasonably restrict the use of the property or would result in significant degradation of the property or adjacent properties; or 4. Granting the modification or waiver would serve a public purpose of greater import than would be served by strict application of the regulations sought to be modified or waived. 4. Engineering evaluation relative to item #3: Sub -items 3 and 4 apply in that public use is served by collective improvements at Thomas Jefferson Foundation property. Due to the mountainous terrain, designs minimize or avoid impacts to natural and man -made critical slopes. Design is to be commended. Please feel free to call if you have any questions: tel - 434.296.5832 — x3069. Thank you. File: SDP200800155 CSW thom_jeff foundation-4 water -sewer improvements-080315