Loading...
HomeMy WebLinkAboutZMA201500006 Review Comments Zoning Map Amendment 2015-10-02ALBEMARLE COUNTY COMMUNITY DEVELOPMENT — Information from Service Providers To be filled out by ACSA for ZMA's and SP's ZMA201500006: Shadwell Estates 1. Site is in jurisdictional area water only to existing structures. 2. Distance to the closest water line if in the development area is 45 feet. 3. Distance to the closest sewer line if in the development area is N/A (no sewer in the vicinity) feet. 4. Capacity issues for sewer that may affect this proposal N/A 5. Requires Rivanna Water and Sewer Authority capacity certification N/A 6. Water flow or pressure issues that may affect this proposal: The applicant proposes private well and septic. No water flow or pressure issues will affect this proposal. 7. Red flags" regarding service provision (Use attachments if necessary) Currently there is a 2" water meter and vault located on the northern corner of the property. This meter serves 1296 Clifton Inn Drive. The proposed development will impact the private side of the water service. The ACSA will allow a water main extension to provide a fire hydrant at the entrance to this proposed site. As part of the water main extension, the applicant shall relocate the Clifton Inn meter to the end of the new water main. A vault upgrade for the existing water meter may be required. The ACSA will inspect the existing vault to determine its condition. The water main extension will require a construction review submittal (3 sets of plans along with a water data sheet) to the ACSA during the final site plan stage.