HomeMy WebLinkAboutWPO201500012 Plan - Stormwater 2015-04-29 TM p\c 28 Blackwell Park Lane,Suite 201 Warrenton,VA 20186 PHONE 540.349.4500 April 29,2015 Via Hand Delivery County of Albemarle Department of Community Development 401 McIntire Road,Room 227 Charlottesville,VA 22902-4596 Attn: Justin Deel Re: WP0201500012 WPO I-64 Treatment Facility Plan 1St Review Comments 5th Street Station 5th Street SW&Avon Street Ext. Charlottesville,VA 22902 Albemarle County BE#V122001 Dear Mr.Deel: Bohler Engineering is pleased to submit on behalf of Avon Holdings LLC, the revised WPO I-64 Treatment Facility Plan for the proposed 5th Street Station at 5th Street SW & Avon Street Ext. in Charlottesville, VA. The following is our comment response letter addressing comments received from you dated April 8,2015. Each comment is addressed and responded to as follows: Stormwater Pollution Prevention Plan(SWPPP) Comment 1: The SWPPP content requirements can be found in County Code section 17-405. A SWPPP must contain (1)a PPP, (2)an ESCP, (3)a SWMP, and(4)any TMDL measures necessary. a. Please incorporate this plan, upon approval, into the existing SWPPP for this project. Response 1: Comment noted, and will be incorporated. Pollution Prevention Plan(PPP) Comment 1: The PPP content requirements can be found in County Code section 17-404. a. Please incorporate this plan,upon approval, into the existing SWPPP for this project, Response 1: Comment noted, and will be incorporated. CIVIL AND CONSULTING ENGINEERS • PROJECT MANAGERS • SURVEYORS • ENVIRONMENTAL CONSULTANTS • LANDSCAPE ARCHITECTS WWW.BOHLERENGINEERING.COM Justin Deal WPO 1-64 Treatment Facility Plan 1, N i, I w 1 l R I 1St Review Comments 4/29/15 Page 2 of 2 Stormwater Management Plan(SWMP) Comment 1: VSMP Regulation 9VAC25-870-108 requires the VSMP authority to approve or disapprove a SWMP. This plan is disapproved, and the reasons are provided in the comments below. The stormwater management plan content requirements can be found in County Code section 17-403. a. The constructed wetland should be designed to capture and treat its entire drainage area. This design excludes the on-site impervious area with respect to storage. Please use the total impervious area for your storage calculations, including both on- site and off-site, and adjust the constructed wetland accordingly or re-route the onOsite runoff so that the current configuration is adequate. Response 1: Constructed wetlands have been revised to allow adequate volume for both the off-site and on-site drainage area. Please see Sheet 6. Should you have any questions regarding this project or require additional information, please do not hesitate to contact me at(540)349-4500. Sincerely, Bohler Engineering Ryan Yauger DRH/1s H:\12\V122001\Permitting\Jwisdictional Letters\WPO 1-64\150429 WPO 164 1st Review CRL.doc CIVIL AND CONSULTING ENGINEERS • PROJECT MANAGERS • SURVEYORS • ENVIRONMENTAL CONSULTANTS • LANDSCAPE ARCHITECTS WWW.BOH LERENGI NEER I NG.COM