Loading...
HomeMy WebLinkAboutSDP201500020 Approval - County Initial Site Plan 2015-11-12r. COUNTY OF ALBEMARLE Department of Community Development 401 McIntire Road, North Wing Charlottesville, Virginia 229024596 Phone (434) 296 -5832 November 12, 2015 Justin Shimp 201 E. Main Street, Suite M Charlottesville, VA 22902 RE: SDP201500020 Inglewood Terrace — Initial Site Plan Dear Sir: The Agent for the Board of Supervisors hereby grants administrative approval to the above referenced site plan. This approval shall be valid for a period of five (5) years from the date of this letter, provided that the developer submits a final site plan for all or a portion of the site within one (1) year after the date of this letter as provided in section 32.4.3.1 of Chapter 18 of the Code of the County of Albemarle, and thereafter diligently pursues approval of the final site plan. The final site plan will not be considered to have been officially submitted until the following items are received: 1. A final site plan that satisfies all of the requirements of section 32.6 of Chapter 18 of the Code. 2. A fee of $1,613. Please submit 9 copies of the final plans to the Community Development Department. The assigned Lead Reviewer will then distribute the plans to all reviewing agencies (also, please submit 3 copies of the final site Plan along with water and sewer data sheets directly to ACSA Attention Michael Yleira. PE for construction review). Once you receive the first set of comments on the final site plan, please work with each reviewer individually to satisfy their requirements. The Department of Community Development shall not accept submittal of the final site plan for signature until tentative approvals for the attached conditions from the following agencies /reviewers have been obtained: SRC Members: Albemarle County Planning Services (Planner) - 3 copies [Christopher Perez (434) - 296 -5832 Ext. 3443] Albemarle County Engineering Services (Engineer) - 1 copy [Justin Dee] (434) -296 -5832 Ext. 3565] Albemarle County Information Services (E911) - 1 copy [Andy Slack (434) -296 -5832 Ext. 33 84) Albemarle County Building Inspections - 1 copy [Jay Schlothauer (434) -296 -5832 Ext. 32281 Albemarle County Department of Fire Rescue - 1 copy [Robbie Gilmer 434 - 531 -6606] Albemarle County Service Authority - 1 copy [Alex Morrison (434) 9774511 Ext. 116] Virginia Department of Transportation - i copy [Shelly Plaster (434) 422 -9373] If you have any questions about these conditions or the submittal requirements please feel free to contact me at Extension 3443, cperez @albemarle.org. Sincerely, , Christopher P. Perez Senior Planner �C County of Albemarle Department of Community Development 401 McIntire Road, Charlottesville, VA, 22902 Phone 434 - 296 -5832 Memorandum To: Justin Shimp (iustin@shimp- engineering com) From: Christopher P. Perez, Senior Planner Division: Planning Date: November 12, 2015 SubZect: SDP201500020 Inglewood Terrace — Initial Site Plan Fax 434 -972 -4126 The County of Albemarle Planning Division will recommend approval of the plan referenced above once the following comments have been satisfactorily addressed (The following comments are those that have been identified at this time. Additional comments or conditions may be added or eliminated based on further review.): [Each comment is preceded by the applicable reference, which is to the Subdivision/Zoning Ordinances unless otherwise specified.] 1. [Comment] This application was reviewed against Site Development Plan requirements only. It appears that lot lines and a `private road' are shown on the plan, but no subdivision application nor private road request was submitted. Any subdivision related comments are provided for reference only unless necessary for site plan approval. 2. [32.5.2(m)] The private street serving the development is proposed within an existing publicly dedicated right -of -way, this is not approvable. VDOT never accepted the portion of the right -of -way labeled as `Unimproved Inglewood Drive' into the State Secondary System and the County still owns it. Either pursue vacation of the right of way pursuant to State Code 15.2 -2272 prior to final site plan and/or final subdivision plat approval OR upgrade the existing roadway to meet current VDOT standards from the point where VDOT maintenance ends. This will include a suitable turn around at the end of state maintenance, removal of the existing parking area, continuation of curb and gutter, tie in of the existing driveway of TMP 061 KO- 05 -0D- 00400, and the dedication of right -of -way or easements as necessary. Please show these improvements and easements or right -of -way prior to final site plan and/ or subdivision plat approval. 3. [Comment] Approval and recordation of a plat showing the vacation of the property line between TMP 61K -10 -OA and TMP 61K- 10 -OA2 is required prior to final site plan approval. Include the deed book/page reference number on the final site plan. It may be appropriate to combine all platting items on a single plat (if other items exist). 4. [Comment] VDOT approval of the proposed entrance to the site shall be required prior to final site plan approval. 5. [14- 412(A)(3),14- 412(A)(3)(b) and 14- 412(B)] VDOT road standards apply to the proposed private street. Show the 24' required width FC/FC on the final site plan. 6. [32.5.2(i),15.2.1(3)] A private street request must be submitted prior to final subdivision plat and final site plan approval. This private street request can be reviewed administratively due to the presence of attached dwellings. A maintenance agreement for the private street must be submitted for review and approval by the County Attorney's Office with the subdivision application. 7. [32.5.2(n),14- 410(H)] Private Streets in the Development Area in the development areas, streets shall be constructed with curb or curb and gutter, sidewalks and planting strips. Sidewalks and planting strips shall be designed and constructed in compliance with section 14-422 (Sidewalks and planting strips for street trees and other vegetation shall be established on both sides of each new street within a subdivision creating lots for single family detached and single family attached dwellings in the development areas.) Revise to provide sidewalks and landscape strips on both sides of the new street. Otherwise when the private street request is submitted assure the appropriate variation or exception request is made pursuant to Section 14- 422(F) & 14- 203.1. This item shall be acted on prior to final subdivision plat and final site plan approval. 8. [32.5.2(n), 4.12.15(8)] Curb and gutter in parking areas and along travelways. Either provide the required curb and gutters in the parking area or submit a request and justification for a modification/waiver under Section 4.12.2(C) & (C)2. This is an agent approved waiver which can only be acted on after consultation with the County Engineer, who shall advise whether the proposed waiver or modification would equally or better serve the public health, safety or welfare. This item shall be acted on prior to final subdivision plat and final site plan approval. 9. [32.5.2(b), 4.12.16(c)] Minimum parking space size. Are the 6' -wide parking spaces fronting Lots 4 -9 for motorcycles/mopeds? If so, label the spaces as such. If not, on the plan label what they are being utilized for. These spaces shall not be counted towards the minimum required spaces. 10. [4.12.16(C)] The two proposed parking spaces fronting TMP 061KO -05 -OD -00400 are required to be 18' in length. Currently they are depicted as 16' in length. Revise the final site plan accordingly. 11. [32.5.2(i)] Street trees shall be required for this development. Prior to final site plan approval a landscape plan shall be provided. 12. [32.5.2(i), 4.6.3,15.2.1(3),15.31 Setbacks. The setbacks throughout the plan are not accurately depicted. This development is classified as "infill development" pursuant to Section 4.19 of the County Code. The correct setbacks for this development are as follows: Front Minimum — 30 foot Front Maximum — none Side Minimum & Maximum -- none Rear Minimum - 20 foot Rear Maximum -- none Revise the plan and notes on Sheet 1 accordingly. 13. [32.5.2(1)] Per the June 19, 2015 letter by David L. Powell, Environmental Specialist, which was submitted to staff on October 29, 2015, the stream feature has been categorized as an Intermittent Stream. The study was reviewed by County Engineering staff and has been determined to be adequate. An adjacent property owner has contacted staff and expressed his concerns with this study and has opted to contract a stream categorization study of his own by a licensed professional. At the time of this approval letter the second study has not been provided. When the study is submitted it shall be considered and reviewed by County Engineering staff. If the second study contradicts the June 19t''. 2015 study, the County Engineer will make a determination to classify the stream. 14. [32.5.2(d), 32.5.2(f)] The 9' retaining wall is acting as a dam for the stream that may cause flooding on neighboring properties in the event of heavy rainfall. Have any studies been conducted to assess the max flow of this stream to assure that the 60" storm sewer pipe is adequate to avoid such flooding? If so, please provide copies of the study to myself and Engineering, This item may pose an issue for the development during the WPO plan review of the project. Please work with Engineering staff to address this concern prior to final site plan approval. Also, the `New 60" HDPE Storm Sewer' discharges water into the existing Swale on TMP 61K- 5 -D -4. Will piping the water under the proposed buildings increase the velocity /flow of discharged water potentially increasing erosion on the neighboring property and/or impact properties downstream? During the WPO plan review and prior to final site plan approval please work with Engineering staff to address this concern. 15. [32.5.2(p) & 32.7.9.71 Screening. The proposed outfall of the stream shall be screened from the adjacent residential lots (TMP 061K0- 05 -0D- 00400& 061KO- 09- 00- 003130). Provide the required screening on the final site plan's landscape plan. 16. [32.5.2(a),15.41, 3.11 Maintenance of existing wooded areas. For the undisturbed areas to qualify for a 10% density bonus, demonstrate in an exhibit that the area meets the definition of "Wooded Areas" per section 3.1 of the ordinance. Provide the exhibit and a conservation plan as specified in section 32.7.9 prior to final site plan approval and/or final subdivision plat approval. On the final subdivision plat, show the conservation area and provide the following note: "Lot acreages shown hereon were calculated under the Bonus Level Cluster development requirements. Lots shown hereon comply with section 15.4.1 "Environmental standards " by conserving acreage area that comprises _Yo of the total area of the subdivided parcels. " 17. [32.5.2(a),15.4.3] Affordahle housing. Clearly identify the affordable unit on the final subdivision plat. 18. [32.5.2(a), 15.5, 15.3, 4.7] Cluster Development. On the plan clearly distinguish what area is being counted towards the required Open Space B & C, and omit the square footage for the road and parking from the open space totals. On the final subdivision plat list who shall own and maintain the open space. An open space maintenance agreement approved by the County Attorney's office shall be required prior to final subdivision plat approval. 19. 132.5.2(a), 15.5, 15.3, 4.71 Cluster Development. On sheet C1, under Impervious Area Schedule, 33,500 SF is listed under "Area in open space'; however, on sheet C3 open space A -D add up to 27,676 SF. Correct and coordinate calculations throughout the plans. 20. [32.5.2(d)] Prior to final site plan approval provide a temporary grading and construction easement or license agreement for the installation of the proposed DI and New 15" HDPE Storm Sewer on TMP 061KO- 05-OC- 01300. Also, revise the plan to provide this property owner's name and TMP. 21. [32.5.1(c), 32.5.2(n)] Dimensions. On the plan provide the dimensions of the proposed structures. 22. [Comment] On the plans provide the deed book page reference information for the existing 30' Joint Access Easement. Staff research determined that the maintenance agreement for this join access easement is DB1654 -291. Revise accordingly. 23. [Comment] The adjacent property owner of TMP 061 KO- 10- 00 -OOOA1 has a portion of his existing driveway on land that is part of your development and property (TMP 061 KO- 10- 00- OOOA2). It appears that some grading is taking place on a portion of his driveway that is on your land. He has contacted County staff (Engineering and myself) and is very concerned with this aspect of the plans and does not want this to take place. It is recommended that you contact this citizen and try and work out this issue. I have his contact information and wild provide it to you upon your request. 24. 132.5.2(n) & (p)] The following will be required for final site plan approval: If lighting is proposed: Outdoor lighting information including a photometric plan and Iocation, 3 description, and photograph or diagram of each type of outdoor luminaire [Sec. 32.7.8 & Sec. 4.17] A landscape plan in accordance with [Sec. 32.7.91. Please contact Christopher P. Perez in the Planning Division by using cnerezCa Ibemarlex or 434 - 296 -5832 ext. 3443 for further information. County of Albemarle Department of Community Development Memorandum To: Christopher Perez, Planning From: Justin Deel, Engineering Date: 3 November 2015 Subject: Inglewood Terrace (SDP201500020) The initial site plan for Ingleside Terrace has been reviewed. The following concerns should be addressed; 1. The neighboring community, according to at least one member of that community, has expressed intent to provide an additional study to contest the provided determination, because they strongly feel that the stream is indeed perennial. Should a new study be presented to conflict with the provided determination, this new information must be reviewed and considered. 2. Concerning previous comment #2; this comment is referring to TMP 61K- 05- OD -4's potential to be an erosion impact area during and after construction. The comment response that the ultimate configuration will not be erosive does not address the E &SC (construction) phase. This can be addressed with the E&SC plan, and will be vigorously scrutinized at that time. The previously requested drainage area verification will need to be provided as well. 3. Within the steep slopes overlay district, the maximum height of a single retaining wall is 6 feet [18- 30.7.5]. This plan proposes a 9' to 10' wall passing through an area designated as a managed slope. Please adjust. Note that the minimum horizontal distance between individual walls in a stepped wall system is 3 feet. 4. The previously requested drainage and SWM easements are not shown. 5. Concerning road width (previous comment #7); the referenced footnote in the comment response does not allow for a reduction in the minimum 24' face of curb to face of curb width for up to 2,000 ADT; rather it allows for a reduction in the minimum width's for 2,001 to 4,000 ADT. Note that there is no reference to footnote 9 in the up to 2,000 ADT widths. The minimum width is 24', please adjust. 6. Stormwater quality does not appear to be addressed with this plan. The previously requested concept BMP plan has not been provided. 7. Parking lot sidewalks do not meet the minimum 5' width. There are no exceptions to this. See Albemarle County Design Standards Manual for minimum configurations. Comments for Final Site Plan (previously provided by Michelle Roberge and remain unaddressed on plans and in comment response letter) 8. Retaining walls greater than 4' require railing. 9. Design proper inlet for stormsewer pipe bypassing runoff north of site. It appears there is an existing channel. Are you proposing to improve the channel to the stormsewer inlet? 10. Verify channel at outfali is adequate. 11. A separate road plan will need to be approved and bonded prior to the approval of a subdivision plat. 12. VDOT approval is necessary for connection to public road and for improvements within their right -of -way. 13. Show groundcover, not grass, for slopes greater than 3:1. 14. A VSMP application shall be submitted and approved prior to the approval of the final site plan. 15. One parallel parking does not meet the 18' requirement for length. 16. Verify guardrails are not warranted under GRIT manual. Otherwise, please show. Review Comments SDP201500020 Project Name: tglewood Terrace - Initial Date Completed: Reviewer: DepartmentlDivision'Agency- Reviews Comments_ Nednesday, October 21, 2015 4ndrew Slack E911 initial Site Plan The applicant should have a new road name before the final plans are submitted. The road name of 'Inglewood Terrace' would be a name that meets the County standards for an acceptable road name. If the applicant would like to use a different name; please contact this office with a list of three (3) proposed road names for approval before submitting the final plans- Project Name- Date Completed- Reviewer: Dep artment/D iv isiorLIAg ency: Reviews Comments_ Review Comme nt SDP201 500020 i+plewood Terrace - Initial rhursday, October 22, 2016 jay Schlothauer 1-1, Inspections Based on plans revised October 15, 2015 No comments or conditions Initial Site Plan �J Review Comments SDP201500020 Project Dame: ]giewood Terrace - Initial Date Completed: Reviewer: Department/D ivisio nlAg envy: Reviews Comments: Saturday, October 31, 2015 Robbie Gilmer Fire Rescue Based on plans dated 10/15115. Initial SiiePlan 1. Dead end roads greater then 150' require an approved turn around for emergency vehicles. per 2009 VSFPC 503.2.5 Approved turn arounds for emergency vehicles include but not limited to the following dimensions, 120 -foot Hammerhead's, 60 -foot "Y" or 96 foot diameter cul-de -sac. if more information is needed please contact Robbie Gilmer of the Albemarle County Fire Marshal Office.. Project Name_ Date Completed- Reviewer_ DepartmentlDivisionfAg ency_ Reviews Comments- Review Comments SDP201500020 tglewood Terrace - Initial vlonday, October 26. 2015 Alexander Morrison L- _------ -.._.a.. - -- - - -- - �ACSA From- Alex Morrison [mailio_amorrison serviceauthoCdy org] Sent: Monday, October 26, 2015 10:51 AM To- Christopher Perez <cperez aalbemarle -org> Subject SDP201520- Inglewood Terrace - Initial Site Planv Chris, Initial Site Plan F1, I have reviewed the above referenced initial site plan.. I hereby recommend approval with the following conditions, • Submit 3 copies of the final site plan, along with water and sewer data sheets, to the ACSA (Attn:: Michael'Vieira, PE) for construction review.. 4evise The proposed landscaping conflicts with existing and proposed water and sewer infrastructure. the landscaping plan The ACSA is scheduling a fire flow test for this development The report will be made available once the test is complete_ Alexander J. Morrison, P_E- Civil Engineer Albemarle County Service Authority 168 Spotnap Road Charlottesville, Virginia 22911 (0) 434 - 9774511 Ext. 116 (C) 434- 981 -5577 (F) 434 - 979 -0698 COMMONWEALTH of VIRGINIA DEPARTMENT OF TRANSPORTATION 1801 prangs hoed Culpeper. Virg"s 22709 Charles A Kilpatrick, P.E. Commissioner November 5, 2015 Mr. Christopher Perez County of Albemarle Department of Community Development 401 McIntire Road Charlottesville, VA 22902 Re: SDP - 2015 -00020 Inglewood Terrace - Initial Site Plan Dear Mr. Perez: We have reviewed the Initial site plan for Inglewood Terrace, with the latest revision date of October 15, 2015, as submitted by Shimp Engineering and offer the following comments: 1. Previous conunent: "We recommend a YIELD sign on Inglewood Court to create a smooth through movement and efficient operation ". Our Traffic section feels that a YIELD sign should be added on Inglewood Court rather than Inglewood Drive as shown. The plan should be revised accordingly. 2. Previous comment:" Since the private street is proposed within an existing public right -of -way (ROW) we recommend vacating a portion of the ROW to the intersection, of Inglewood Drive and Inglewood Court". The limits of the ROW appear to not have been changed and the intent remains unclear. The limits of the proposed Public ROW lute should be clearly shown on the plans. 3. Previous comment: "Intersection sight lines should be shown at the intersection and a sight distance profile should be provided ". Noted: The engineer is waiting on a more detailed survey before responding, however, adequate sight distance should be verified, for Inglewood Court, at this stage of review. 4. Previous comment: "Additional detail should be provided at the intersection of Inglewood Court and Inglewood Drive ". For example: Additional survey information should be provided for the other side of Inglewood Court for the placement of the YEILD sign and in order to verify adequate line of sight. Additional detail should also be shown on the east side of Inglewood Drive, How will the proposed private street transition into Inglewood Drive when it is wider than 20'. 5. Additional continents concerning the storm sewer, pavement etc. will be generated during the final submittal. If you need additional information concerning this project, please do not hesitate to contact me at (434) 422 -9894. Sincerely, Shelly A Plaster Land Development Engineer Culpeper District WE KEEP VIRGINIA MOVING