HomeMy WebLinkAboutSDP201500020 Review Comments Initial Site Plan 2015-11-03Short Review Comments Report for:
SDP201500020
SubApplication Type:
Inglewood Terrace - Initial
Initial Site Plan
Date Completed:06/03/2015
Reviewer:Christopher Perez CD
Review Status:Requested Changes
Reviews Comments:
Division:
Date Completed:06/03/2015
Reviewer:Michelle Roberge Engineering
Review Status:Requested Changes
Reviews Comments:
Division:
Date Completed:05/05/2015
Reviewer:Jay Schlothauer Inspections
Review Status:No Objection
Reviews Comments:Based on plans dated April 20, 2015.
No comments or conditions.
Division:
Date Completed:06/02/2015
Reviewer:Shelly Plaster VDOT
Review Status:Requested Changes
Reviews Comments:
Division:
Date Completed:06/01/2015
Reviewer:Alexander Morrison ACSA
Review Status:See Recommendations
Reviews Comments:
From: Alex Morrison [mailto:amorrison@serviceauthority.org]
Sent: Monday, June 01, 2015 12:50 PM
To: Christopher Perez
Subject: SDP201500020: Inglewood Terrace - Initial Site Plan
Chris,
I have reviewed the above referenced plan and have the following comments:
•Submit 3 copies of the final water and sewer plans to the ACSA, attention Jeremy Lynn PE,
along with water and sewer data sheets for review and approval.
•Show the existing water and sewer easements.
•Call out existing and proposed line sizes.
•Call out all fittings.
•Provide fire hydrants spaced at 400’.
•Manholes are not permitted in parking spaces.
•The existing water main is a 6” cast iron main. The applicant shall furnish a hydraulic report
that shows that the required fire flow can be achieved.
I hereby recommend approval of SDP201500020 with the above conditions. Let me know if you have
any questions.
Alexander J. Morrison, P.E.
Division:
Page:1of3 County of AlbemarlePrinted On:November 17, 2015
Civil Engineer
Date Completed:05/06/2015
Reviewer:Andrew Slack E911
Review Status:Requested Changes
Reviews Comments:The applicant should have a new road name before the final plans are submitted. The road name of
'Inglewood Terrace' would be a name that meets the County standards for an acceptable road name.
If the applicant would like to use a different name; please contact this office with a list of three (3)
proposed road names for approval before submitting the final plans.
Division:
Date Completed:05/26/2015
Reviewer:Robbie Gilmer Fire Rescue
Review Status:Requested Changes
Reviews Comments:Based on plans dated 4/20/15
1. Dead end roads greater then 150' require an approved turn around for emergency vehicles. per
2009 VSFPC 503.2.5
2. Fire Flow test required prior to final approval.
Division:
Date Completed:11/12/2015
Reviewer:Christopher Perez CD
Review Status:Approved
Reviews Comments:
Division:
Date Completed:10/21/2015
Reviewer:Andrew Slack E911
Review Status:Requested Changes
Reviews Comments:The applicant should have a new road name before the final plans are submitted. The road name of
'Inglewood Terrace' would be a name that meets the County standards for an acceptable road name.
If the applicant would like to use a different name; please contact this office with a list of three (3)
proposed road names for approval before submitting the final plans.
Division:
Date Completed:10/22/2015
Reviewer:Jay Schlothauer Inspections
Review Status:No Objection
Reviews Comments:Based on plans revised October 15, 2015.
No comments or conditions.
Division:
Date Completed:11/05/2015
Reviewer:Shelly Plaster VDOT
Review Status:Requested Changes
Reviews Comments:
Division:
Date Completed:10/26/2015
Reviewer:Alexander Morrison ACSA
Review Status:Requested Changes
Reviews Comments:
From: Alex Morrison [mailto:amorrison@serviceauthority.org]
Sent: Monday, October 26, 2015 10:51 AM
To: Christopher Perez <cperez@albemarle.org>
Subject: SDP201520: Inglewood Terrace - Initial Site Planv
Chris,
Division:
Page:2of3 County of AlbemarlePrinted On:November 17, 2015
I have reviewed the above referenced initial site plan. I hereby recommend approval with the
following conditions:
•Submit 3 copies of the final site plan, along with water and sewer data sheets, to the ACSA
(Attn: Michael Vieira, PE) for construction review.
•The proposed landscaping conflicts with existing and proposed water and sewer
infrastructure. Revise the landscaping plan.
The ACSA is scheduling a fire flow test for this development. The report will be made available once
the test is complete.
Alexander J. Morrison, P.E.
Civil Engineer
Albemarle County Service Authority
168 Spotnap Road
Charlottesville, Virginia 22911
(O) 434-977-4511 Ext. 116
(C) 434-981-5577
(F) 434-979-0698
Date Completed:10/31/2015
Reviewer:Robbie Gilmer Fire Rescue
Review Status:Requested Changes
Reviews Comments: Based on plans dated 10/15/15.
1. Dead end roads greater then 150' require an approved turn around for emergency vehicles. per
2009 VSFPC 503.2.5
Approved turn arounds for emergency vehicles include but not limited to the following dimensions,
120-foot Hammerhead's, 60-foot "Y" or 96 foot diameter cul-de-sac. If more information is needed
please contact Robbie Gilmer of the Albemarle County Fire Marshal Office.
Division:
Date Completed:11/03/2015
Reviewer:Justin Deel Engineering
Review Status:Requested Changes
Reviews Comments:
Division:
Page:3of3 County of AlbemarlePrinted On:November 17, 2015