HomeMy WebLinkAboutWPO201200081 Review Comments As-Built Reviews 2015-11-18Al
vr�N1Q
COUNTY OF ALBEMARLE
Department of Community Development
401 McIntire Road, Room 227
Charlottesville, Virginia 22902 -4596
Phone (434) 296 -5832 Fax (434) 972 -4126
Project:
Plan preparer:
Owner or rep.:
Plan received date;
Date of comments:
Reviewer:
Greyrock West
Dominion Engineering
Southern Development Group, Inc.
30 October 2015
12 November 2015
Max Greene
AT0201200081
[mmyers @dominioneng.com]
Thank you for submitting the as -built plans for the Greyrock West Subdivision Storm Water
Management Facility. The SWM (VSMP) plans from the original water protection plan
WP0201200081 have been compared to the as -built plan and the site work does not appear to
agree with the approved plan. The calculation for the as -built condition of the basin appear to
address the discrepancies in construction due to bedrock. However, the following were not
adequately shown on the as -built plan:
The profile of the existing SWM basin does not appear to match the profile on the
approved plans. Please show the approved profile overlaid onto the full constructed
profile.
2. The rip -rap wall is not shown.
3. The trash cage is not shown.
4. Concrete base dimensions are not shown.
5. Basin inlet and outlet will need to be cleaned of sediment.
6. The stormwater system leading into the basin needs to be cleaned due to the amount of
sediment and stone blocking portions of the pipe and manhole structures.
Please contact this office for clarification on the as -built plan requirements.
File: VSMP as -built review letter.doc