HomeMy WebLinkAboutSDP201500057 Review Comments Initial Site Plan 2015-12-21ilil� IIII�
COUNTY OF ALB ART
Department of Community Development
401 McIntire Road, North Wing
Charlottesville, Virginia 22902 -4596
Phone (434) 296 -5832 Fax (434) 972 -4126
December 21, 2015
Tim Miller
Meridian Planning Group LLC
1413 Sachem Place, Suite one
Charlottesville, VA 22901
SDP201500057 General Industrial Office — Initial Site Plan
Mr. Miller:
The Site Review Committee has reviewed the development proposal referenced above. Initial comments
for the following divisions of the Department of Community Development and other agencies, as
applicable, are attached:
Albemarle County Planning Services
Architectural Review Board (ARB) [Comments pending to be forwarded once received]
Albemarle County Engineering Services
Albemarle County Information Services (E911)
Albemarle County Building Inspections
Albemarle County Department of Fire Rescue
Albemarle County Service Authority
Virginia Department of Transportation
Comments reflect information available at the time the development proposal was reviewed, and should
not be considered final. However, the Site Review Committee has attempted to identify all issues that
will be required to be resolved prior to Final Site Plan approval. The Lead Reviewer will either approve
with conditions or deny the Initial Site Plan within 15 days of the Site Review Meeting.
Please contact me at your earliest convenience if you have questions or require additional information.
Sincerely,
Senior Planner
County of Albemarle
Department of Community Development
401 McIntire Road,
Charlottesville, VA, 22902
Phone 434 -296 -5832 Fax 434 - 972 -4126
Memorandum
To: Tim Miller
From: Christopher P. Perez, Senior Planner
Division: Planning
Date: December 21, 2015
Subject: SDP201500057 General Industrial Office — Initial Site Plan
The County of Albemarle Planning Division will recommend approval of the plan referenced above once the
following comments have been satisfactorily addressed (The following comments are those that have been
identified at this time. Additional comments or conditions may be added or eliminated based on further review.):
[Each comment is preceded by the applicable reference, which is to the Subdivision/Zoning Ordinances unless
otherwise specified.]
Prior to initial site plan approval, at a minimum, comments 1 -10 shall be addressed in a resubmittal.
[325.2(p), 26.2, 32.7.9.2(b)] Proposed use. Pursuant to Section 26.2(a), Outdoor Storage located in and visible from
the Entrance Corridor (EC) requires a Special Use Permit (SP). If the outdoor storage is completely screened and is
determined by the Architectural Review Board (ARB) not to be visible from the EC, then a SP is not required. If ARB
determines it to be visible from the EC then a SP shall be required prior to approval of the initial site plan.
Based on the above, prior to initial site plan approval a complete landscape plan for the entire site that complies with
section 32.7.9 is required. Also, address any ARB landscaping and screening comments once ARB review is complete.
Request the project be deferred to allow revisions and ARB review of the revisions to take place prior to action on the
plan.
2. [32.5.2(j),(k),Q)] Existing and proposed utilities. On the landscape plan depict, label and dimension all existing and
proposed utilities and utility easements including water, sewer, drainage, telephone, cable, electric and gas. Label all
existing easements with the Deed Book and Page Number. The above information shall be used to verify that no
conflicts exist between landscaping and utilities.
[32.7.9.4(b)] Existing trees may be preserved in lieu of planting new plant materials in order to satisfy the landscaping
and screening requirements of section 32.7.9, subject to the agent's approval. If you intend to use existing trees to
satisfy any of the landscape plan requirements, please include the following:
1. Areas and other features shown on landscape plan. The landscape plan shall show the trees to be preserved,
the limits of clearing, the location and type of protective fencing, grade changes requiring tree wells or walls,
and trenching or tunneling proposed beyond the limits of clearing.
2. Conservation checklist. The applicant shall AN a conservation checklist approved by the agent to ensure that
the specified trees will be protected during construction. Except as otherwise expressly approved by the agent
in a particular case, the checklist shall conform to the specifications in the Virginia Erosion and Sediment
Control Handbook, pages III -393 through III -413, and as hereafter amended.
4. [32.5.2(e), 32.7.9.4(c)] Existing landscape features. On the landscape plan identify whether existing wooded areas are
evergreen, deciduous, or a mix thereof.
[32.7.9.6] Landscaping within a parking area. Modify landscape parking calculation to provide required tree count.
Also, depict and label the location of the required 640 SF of planting area.
6. [32.7.9.7] Screening. Provide the required screening of the industrial use adjacent to the rural areas zoning district.
Also, provide the screening for the required dumpster pad (see comment 17 below).
7. [32.7.9.5] Street Trees. Street trees are required along all existing streets; revise calculations on sheet C -205 and
provide the required street trees along the frontage of Airport Road and Coffey Drive.
8. [32.7.9.8] Tree canopy. The minimum required tree canopy for the site is ten (10) percent of 326,205 SF. Revise the
calculations to accurately reflect the acreage of the site.
9. [5.1.52] Outdoor Storage in Industrial Districts. Except as otherwise expresslypermittedfor aparticular use, the
outdoor storage of parts, materials and equipment in an industrial district shall be subject to the following:
a. Storage areas shall be screened by a solid wall or fence, including solid entrance and exit gates, not less than seven
(7) feet nor more than ten (10) feet in height.
b. No wall or fence screening a storage area shall encroach into a sight distance triangle.
c. The parts, materials and equipment stored in a storage area shall not be stacked higher than the screening wall or
fence.
d. No outdoor storage shall be located within fifty (50) feet of a residential or agricultural district.
e. The outdoor storage of recyclable materials at a recycling collection or recycling processing center is prohibited.
Screen the entire storage area as provided in Section 5.1.52(a) & (b). Under minimum yards/setbacks, provide the
following note: "Parts, materials and equipment stored in the storage area shall not be stacked higher than the
screening fence and plantings pursuant to 5.1.52(c). "
10. [35.1] Fees. As previously discussed, the incorrect application fee was paid by the applicant during submittal of the
project. Please work with intake staff to process a refund and pay the correct fee of $1,290 plus $0.016 per square foot
of nonresidential structures. Also, pay the $200 public notification fee. The above shall take place prior to any further
review /action of the plan.
11. [32.5.2(b)] Proposed use. On sheet C -100 revise the proposed use to also include Outdoor Equipment Storage. Also,
provide the maximum acreage occupied by each use.
12. [4.14, 4.14.1- 4.14.51 Performance standards for industrial uses apply to the proposal. On sheet C -100 provide the
following note: "Performance standards for industrial uses apply to the proposal as dictated by Section 4.14.1 - 4.14.5
of County Code and the use shall be subject to those standards ". Also, provide the following note: "This use is subject
to Section 4.18 Noise regulations. "
13. [4.14.5] Certified Engineers Report. A Certified Engineers Report shall be completed/complied with prior to the
approval of the final site plan.
14. [32.5.2(a)] General information. The adjacent parcel, TMP 32 -10, is zoned Rural Area (RA). Revise the plan
accordingly.
15. [32.5.1(c)] Boundary lines. The shared parcel boundary between TMP 32 -17A and TMP 32 -17135 does not match
County GIS nor the plat of record referenced on the site plan. Verify the shared boundary line and provide recorded
documentation.
16. [32.5.1(c), 32.5.2(x), 26.5, 4.20] Minimum Yards. Throughout the plan clearly label and depict all of the minimum yard
requirements for the proposal. The plan shall be revised to meet the setback requirements.
Adi acent to streets
Front minimum - 10' from right -of -ways (Airport Road and Coffey Drive)
Front maximum — none
Adjacent to district other than commercial or industrial district
Side yard minimum adjacent to RA zoning — 50 feet for structures & 30 feet for parking
Side yard maximum — None
Buffer adjacent to district other than commercial or industrial district
30' undisturbed buffer between Ll and RA zoning
Building separation
Side yard setback for side abutting industrial zoning - any primary structure shall be constructed and separated in
accordance with the current edition of the Building Code.
17. [4.12.6] Parking required. Parking calculations for the warehouse utilize number of employees in addition to the floor
area of the building. On the plan provide the number of employees for the warehouse. One space is required per
employee. If no employees are planned for the warehouse, please list zero (0) employees for the warehouse.
18. [32.5.2(b)] Proposed use. Provide the maximum amount of paved parking and vehicular circulation.
19. [32.5.2(n), 4.12.13(e), 32.7.9.7] Existing and proposed improvements. A dumpster pad is required for the use based on
gross square feet of the industrial building. On the plan locate and dimension the dumpster pad for the site and provide
required screening of the facility pursuant to section 32.7.9.7. The pad shall not impede any required parking or loading
spaces, nor any pedestrian or vehicular circulation aisles.
20. [4.12.15] Minimum Design Requirements. Label, depict and dimension any loading space and/or loading docks for the
warehouse. Parking areas shall be designed so that all loading spaces, loading docks, and dumpsters are accessible by
delivery and service vehicles when all parking spaces are occupied.
21. [32.5.1(c)] Dimensions. On the plan dimension all proposed improvements, to include: sidewalks, building, access
road, parking drive aisle, 2' parking overhang, fencing, dumpster pad, landscaped areas, signs, new gravel area used for
equipment storage, and new storm water conveyance channel.
22. [32.7.2.3] Sidewalks within a development. Depict and dimension a sidewalk from the proposed building to the storage
area.
23. 132.7.2.31 Sidewalks. Depict and label the existing sidewalks along Airport Road and Coffey Drive.
24. [32.5.1(c), 32.5.2(n)] Dimensions. On the plan dimension the existing structure, to include height.
25. [32.5.2(i)] Streets. Throughout the plan correct the name and state route for "Deerwood Drive (Route 1501)" to
"Coffey Drive (State Route 882)."
26. [32.7.2.1] Vehicular Access to Site. Each entrance onto any public street shall be designed and constructed as required
by the standards of the Virginia Department of Transportation. VDOT approval of the entrance to the site shall be
required prior to final site plan approval.
27. [32.5.2(1)] Watercourses and other bodies of water. On sheet C -100 provide the following note: "This site does not lie
in an Albemarle County water supply watershed "
28. [32.5.2(a)] On the cover sheet provide the site plan number: SDP2015 -57.
29. [32.5.2(n), 4.17] Outdoor lighting. If outdoor lighting is proposed a lighting plan meeting the requirements of section
4.17 shall be required prior to final site plan approval.
Please contact Christopher P. Perez in the Planning Division by using cperez a,albemarle.org or 434 -296 -5832
ext. 3443 for further information.
Project Dame:
Date Completed:
Revievrer_
Dep artrnent/D ivisiorgAg envy_
Reviews Comments_
Review Comments
SDP201500057
general industrial Office - Initial
Tuesday; November 17, 2015
-Max Greene
Engineering
Initial Site Plan
L' 6
'Gutter pan is required for curb with stormwater flows. [18- 4.12.15_g]
'An access road will be required to inspect and maintain the SWIM structure. Please show adequate
vehicular turn- around space at the new facility.. (This office recommends bypassing the oft -site stormwater,
moving the facility to the top of slope for the parking area and adding another facility to capture the
office/road/parking area.)
'New entrance permit may be required from VDOT for change in use of property- Please consult VDOT for
additional information.
'VSMP plan will be required prior to final site plan approval_ (VSMP plan may require a plan for excess soil
proposed to be removed from site)
Review Comments
SDP201500057
Project Name: general Industrial Office - Initial
Date Completed: d vlonday. November 23, 2015 Inl Site Plan
Reviewer: L-4ndrew Slack
DepartmenVDivision/Agency: LE91
Reviews Comments:
The applicant should update the road name shown (D"rwood Drive wig the correct road name of Toff ey
Drive" on the plans before final plans are submitted
Review Comments
SDP201 500057
Project Marne: general Industrial Office - Initial
Date Completed:
Reviewer_
Dep artment/D ivisionfAgency_
Reviews Comments-
4
Aanday, , Novembef 16. 2015
Jay Schlothauer
Inspections
Based can plans dared October 25, 2015.
No comments or conditions-
Initial Site Plan
Review Comments
SDP201500057
Project blame: general Industrial Office - Initial
Date Completed:
Reviewer:
Department/DivisionlAgency:
Reviews Comments:
Saturday, December 19, 2015
,_Robbie Gilmer
Fire Rescue
Based on plans dated 10/26/15
1. Fire flow test required before final approval.
Inl Site Plan
L'J
2 Please add a note to the plans " Knox Box shall be installed per the direction of the Albemarle County Fire
Marshal Office.. Please contact during construction to determine the location. 434-296-5833"
Review Comments
SDP201500057
Project Marne: general industrial Office - initial
Date Completed-
Reviewer:
DepartmentfDivisionlAgency_
Reviews Comments:
Monday, December 21, 2015
4lexander Morrison
ACSA
I have reviewed SDP201500057 and have the following comments-
Initial Site Plan
Include the attached ACSA Water and Sewer General Conditions-
Send water fixture counts to the ACSA for meter sizing when available. The space is currently
served by a 1" water only meter. If a meter upgrade is required, a new tap off of DobleAnn Drive will be
required.. The existing service is tapped off of an RWSA main on the southern side of Airport Road.
• The ACSA has scheduled a field visit to confirm that a force main connection can be made in one
of the existing manholes along the frontage of 3570 DobleAnn Drive
• Provide anticipated daily sewer flows and advise what type of use is proposed in the 3,500 SF
warehouse space (to determine if an industrial discharge permit is required )_
• Sewer connection fees will be required at the time of the building permit application..
I will have an answer on the forcemain connection today- I have the field visit scheduled for this afternoon
Thank you.:
Alexander J. Morrison, P-E.
Civil Engineer
Albemarle County Service Authority
158 Spotnap Road
Charlottesville, Virginia 22911
(0) 434- 977 -4511 Ext. 115
(C) 434 -981 -5577
(F) 434- 979 -0098
November 16, 2015
ACSA GENERAL WATER & SEWER CONDITIONS
1. WORK SHALL BE SUBJECT TO INSPECTION BY ALBEMARLE COUNTY
SERVICE AUTHORITY (ACSA) INSPECTORS. THE CONTRACTOR WILL BE
RESPONSIBLE FOR NOTIFYING THE PROPER ACSA OFFICIALS AT THE
START OF THE WORK.
2. THE LOCATION OF EXISTING UTILITIES ACROSS THE LINE OF THE
PROPOSED WORK ARE NOT NECESSARILY SHOWN ON THE PLANS AND
WHERE SHOWN ARE ONLY APPROXIMATELY CORRECT. THE CONTRACTOR
SHALL, ON HIS OWN INITIATIVE, LOCATE ALL UNDERGROUND LINES AND
STRUCTURES, AS NECESSARY.
3. ALL MATERIALS AND CONSTRUCTION SHALL COMPLY WITH THE CURRENT
EDITION OF THE GENERAL WATER AND SEWER CONSTRUCTION
SPECIFICATIONS, AS ADOPTED BY THE ACSA.
4. DATUM FOR ALL ELEVATIONS SHOWN IN NATIONAL GEODETIC SURVEY.
5. THE CONTRACTOR SHALL BE RESPONSIBLE FOR NOTIFYING MISS UTILITY
(1- 800 - 552- 7001).
6. ALL WATER AND SEWER PIPES SHALL HAVE A MINIMUM OF THREE AND A
HALF (3.5) FEET OF COVER MEASURED FROM THE TOP OF PIPE, OVER THE
CENTERLINE OF PIPE. THIS INCLUDES ALL FIRE HYDRANT LINES, SERVICE
LATERALS AND WATER LINES, ETC.
7. ALL WATER AND SEWER APPURTENANCES ARE TO BE LOCATED OUTSIDE
OF ROADSIDE DITCHES.
8. VALVES ON DEADEND LINES SHALL BE RODDED TO PROVIDE ADEQUATE
RESTRAINT FOR THE VALVE DURING A FUTURE EXTENSION OF THE LINE.
9. TREES ARE NOT PERMITTED IN THE ACSA EASEMENT.
10. THE CONTRACTOR SHALL BE RESPONSIBLE TO COMPLY WITH THE NO-
LEAD REGULATION REGARDING BRASS FITTINGS EFFECTIVE JANUARY 4,
2014 (SENATE BILL 3874 WHICH AMENDS THE SAFE DRINKING WATER ACT).
COMMONWEALTH of VIRGINIA
DEPARTMENT OF TRANSPORTATION
C iMm. Wgiria 72701
Charles A Mlpatrlak, P.E.
Commissioner
December 15, 2015
Mr. Christopher Perez
County of Albemarle
Department of Community Development
401 McIntire Road
Charlottesville, VA 22902
Re: SDP -2015 -00057 General Industrial Office — initial Site Plan
Dear Mr. Perez:
We have reviewed the General Industrial Office initial site plan, dated October 26, 2015, as submitted by
Meridian Planning Group, LLC, and we offer the following comments:
1. The subject site is located off Route 882, Coffey Drive rather than Route 1501, Deerwood Drive.
Labeling should be updated accordingly.
2. The right-of-way along Airport Road and Coffey Drive should be clearly identified in the plans.
3. The existing entrance on Coffey drive does not meet our minimum corner clearance of 225'.
4. The anticipated average daily trips should be provided.
5. A plan and profile should be provided to ensure there is adequate intersection sight
distance.
6. The proposed sanitary force main should be jacked and bored under Coffey Drive. The
contractor will be held liable repair the damages made within the right-of-way. Also, the
force main should have a minimum vertical offset of 10' from the storm sewer.
If you need further information concerning this project please do not hesitate to contact me at
(434) 422 -9894.
Sincerely,
Shelly A. Plaster
Land Development Engineer
Culpeper District
701 VDOT Way