HomeMy WebLinkAboutSDP201500005 Review Comments 2015-03-30Short Review Comments Report for:
SDP201500005
SubApplication Type:
Fifth Street Place - Initial
Initial Site Plan
Date Completed:03/17/2015
Reviewer:Megan Yaniglos Planning
Review Status:Requested Changes
Reviews Comments:
Division:
Date Completed:02/12/2015
Reviewer:Andrew Slack E911
Review Status:Requested Changes
Reviews Comments:The applicant should contact this office with a list of three (3) proposed road names for approval
before final plans are submitted.
Division:
Date Completed:03/11/2015
Reviewer:Max Greene Engineering
Review Status:See Recommendations
Reviews Comments:1. Existing topography does not appear to match site. House has been razed and stockpile of soil
has been constructed on site. Topography will need to be updated and certified.
2. Water protection plans are reviewed under separate application and will be removed from site
plan package.
3. Army Corp of Engineers permit to disturb wetlands will be required for final plan approval.
4. 15" stormwater conveyance pipe are the minimum allowed per ACDSM. link to ACDSM:
http://www.albemarle.
org/upload/images/forms_center/departments/community_development/forms/design_standards_ma
nual/Albemarle_County_Design_Standards_Manual_02Dec2014.pdf Please up-size the 12" pipes to
15" pipes.
Division:
Date Completed:02/23/2015
Reviewer:Jay Schlothauer Inspections
Review Status:Requested Changes
Reviews Comments:Based on plans stamped February 2, 2015.
Provide barrier-free parking spaces, with related striped access aisles and curb cuts as follows. A
total of nine barrier-free spaces are required for the site:
Rearrange one of the two spaces at the Clubhouse to be van-accessible.
Provide one barrier-free parking space, each, for Buildings 1, 2, 3 and 4.
Provide three barrier-free parking spaces for Building 5. One of these spaces must be
van-accessible.
Division:
Date Completed:03/10/2015
Reviewer:Robbie Gilmer Fire Rescue
Review Status:Requested Changes
Reviews Comments:Based on plans dated 2/2/15
1. Per VSFPC 503.1.1 An Approved fire access road shall extend to with in 150 ft of all the first floor.
Exception Unless an approved Sprinkler system is installed at which the distance is increase to 200
ft.
Division:
Page:1of3 County of AlbemarlePrinted On:January 08, 2016
2. Per VSFPC 503.2.4 Radii in an approved Fire Access road shall have a minimum radii of 25 ft.
3. Per VSFPC 912.2 FDC location shall be located on the street side of the building and in a location
that when hooked to a hydrant the hose doesn't obstruct other responding apparatus.
4.Per VSFPC 507.5.1.1 All FDC's shall be located with in 100 ft per travel way of a Hydrant . This
hydrant shall not count towards the 400 ft spacing per travel way for that building.
5. Per VSFPC 507.5.1 Hydrants shall be installed on 400ft spacing per travel way
6. Per VSFPC 506.1 A Knox Box shall be required on each building. Location to be determined
during construction.
7. Fire Flow test required before fianl approval
Date Completed:03/16/2015
Reviewer:Margaret Maliszewski ARB
Review Status:Requested Changes
Reviews Comments:At its March 16, 2015 meeting, the ARB voted unanimously to forward the following
recommendations to the Agent for the Site Review Committee:
• Regarding requirements to satisfy the design guidelines as per § 18-30.6.4(2), (3) and (5):
1. In areas where wooded area to remain is used to meet tree requirements along 5th Street
Extended, identify existing individual large shade and ornamental trees on the plan by size and
species to show that the minimum requirement can be met. If the requirement can’t be met, show
additional new trees to be planted to meet the requirement.
2. Shift utilities to eliminate conflicts between landscaping and utilities/easements without reducing
the quantity of proposed plants.
3. Ensure that pipes are located to eliminate conflicts with trees along the entrance drive, while
meeting the 40’ on center tree requirement.
4. Add plants along the retaining wall located west of the clubhouse to soften the appearance of the
wall as viewed from the 5th Street Extended corridor.
5. Indicate on the plans the manufacturer, size and color of the block proposed for the retaining walls.
Provide details on the plan showing that wall construction will allow for the planting between the
terraced walls illustrated north of Buildings 1 and 2.
• Regarding recommendations on the plan as it relates to the guidelines:
None.
• Regarding recommended conditions of initial plan approval: A Certificate of Appropriateness is
required prior to final site plan approval.
1. Submit elevations addressing all sides of each building. Ensure that blankness is not a
characteristic of the design.
2. Add the standard window glass note to the architectural drawings: “Visible light transmittance
(VLT) shall not drop below 40%. Visible light reflectance (VLR) shall not exceed 30%.”
3. Add the standard mechanical equipment note to both the architectural and site plans: “Visibility of
all mechanical equipment from the Entrance Corridor shall be eliminated.”
4. Provide the photometric plan at a larger size to increase legibility.
5. Revise the lighting plan to eliminate spillover at the property line in excess of .5 footcandles.
6. Revise the lighting plan using an LLF of 1.0.
7. Identify the light pole and light fixture colors on the lighting plan. Bronze is recommended.
8. Add the standard lighting note to the plan: “Each outdoor luminaire equipped with a lamp that
emits 3,000 or more initial lumens shall be a full cutoff luminaire and shall be arranged or shielded to
reflect light away from adjoining residential districts and away from adjacent roads. The spillover of
lighting from luminaires onto public roads and property in residential or rural areas zoning districts
shall not exceed one half footcandle.”
9. In areas where wooded area to remain is used to meet tree requirements along 5th Street
Extended, identify existing individual large shade and ornamental trees on the plan by size and
species to show that the minimum requirement can be met. If the requirement can’t be met, show
additional new trees to be planted to meet the requirement.
Division:
Page:2of3 County of AlbemarlePrinted On:January 08, 2016
10. Show existing and proposed utilities and easements on the landscape plan.
11. Shift utilities to eliminate conflicts between landscaping and utilities/easements without reducing
the quantity of proposed plants.
12. Ensure that pipes are located to eliminate conflicts with trees along the entrance drive, while
meeting the 40’ on center tree requirement.
13. Add trees along the retaining wall located west of the clubhouse to soften the appearance of the
wall as viewed from the 5th Street Extended corridor.
14. Indicate on the site plan the manufacturer, size and color of the block proposed for the retaining
walls. Provide details on the plan showing that wall construction will allow for the planting between
the walls illustrated north of Buildings 1 and 2.
• Regarding conditions to be satisfied prior to issuance of a grading permit:
None.
Date Completed:03/19/2015
Reviewer:Shelly Plaster VDOT
Review Status:Requested Changes
Reviews Comments:
Division:
Date Completed:03/16/2015
Reviewer:Alexander Morrison ACSA
Review Status:Requested Changes
Reviews Comments:
Division:
Date Completed:03/16/2015
Reviewer:Steve Watson Albemarle County Police Dept
Review Status:See Recommendations
Reviews Comments:advisory only
Division:
Date Completed:03/16/2015
Reviewer:Unassigned No Division Selected
Review Status:See Recommendations
Reviews Comments:jaunt comments- advisory only
Division:
Date Completed:03/16/2015
Reviewer:Victoria Fort RWSA
Review Status:Requested Changes
Reviews Comments:
Division:
Date Completed:03/30/2015
Reviewer:Megan Yaniglos Planning
Review Status:Administrative Approval
Reviews Comments: